acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “cadmium determination”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Dispersive liquid-liquid microextraction for the simultaneous separation of trace amounts of zinc and cadmium ions in water samples prior to flame atomic absorption spectrometry determination

    Sayed Zia Mohammadi, Yar Mohammad Baghelani, Fatemeh Mansori e mais 2Química Nova2012

    In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were…

  2. Preconcentration and determination of cadmium in water and food samples by in situ surfactant-based solid-phase extraction and flame atomic absorption spectrometry

    Mohammad Reza Jamali e Afsaneh BoromandiJournal of the Brazilian Chemical Society2014

    In situ surfactant-based solid-phase extraction (ISS-SPE) is proposed as a preconcentration procedure for the determination of cadmium in water and food samples by flame atomic absorption spectrometry. In the present work, cetyltrimethylammonium bromide was used as a cationic surfactant, hexafluorophosphate ion as an…

  3. Selective cloud point extraction and preconcentration of trace amounts of cadmium prior to flame atomic absorption spectrometric determination

    Shayesteh Dadfarnia, Ali Mohammad Haji Shabani e Ellahe KamranzadehJournal of the Brazilian Chemical Society2010

    Cloud point extraction (CPE) is proposed as a separation and preconcentration procedure for determination of cadmium in water samples by flow injection flame atomic absorption spectrometry (FI-FAAS). The cadmium ion in aqueous solution was converted to [CdI4]2- and its charge was neutralized through ion-pair formation…

  4. Combined Cloud Point and Magnetic Solid-Phase Extraction Using Magnetized Moringa oleifera for Cadmium Determination in Aqueous Samples

    Deborah C. B. Gonçalves, James M. Silva, Weida R. Silva e mais 1Journal of the Brazilian Chemical Society2026

    Cadmium contamination in aquatic environments poses significant environmental and health risks, reinforcing the need for sensitive and selective analytical approaches. Traditional sample preparation techniques often fall short in selectivity and sensitivity, motivating the development of alternative strategies. This…

  5. Evaluation of Two Statistical Tools (Least Squares Regression and Artificial Neural Network) in the Multivariate Optimization of Solid-Phase Extraction for Cadmium Determination in Leachate Samples

    Hélio R. Sousa Filho, Daniel M. Oliveira, Valfredo A. Lemos e mais 1Journal of the Brazilian Chemical Society2015

    This work proposes the use of multivariate optimization as a procedure for cadmium determination in leachate samples via flame atomic absorption spectrometry after solid phase extraction using a minicolumn packed with Amberlite XAD-4 modified with 3,4-dihydroxybenzoic acid. The variables related with the…

  6. Cadmium determination in Lentinus edodes mushroom species

    Vera Akiko Maihara, Patricia Landim da Costa Moura, Marília Gabriela Miranda Catharino e mais 3Food Science and Technology2012

    Many studies have drawn attention to the occurrence and concentration of toxic elements found in the fruiting body of mushrooms. Some edible mushroom species are known to accumulate high levels of inorganic contaminants, mainly cadmium, mercury, and lead. There are about 2,000 known edible mushroom species, but only…

  7. Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes

    QUEILA O. SANTOS, ISLANIA MORENO, LEANDRO DOS SANTOS e mais 3Anais da Academia Brasileira de Ciências2016

    Um simplex de algoritmo modificado foi utilizado na otimização de um sistema de pré-concentração para determinação de cádmio em amostras de sedimentos, cigarros e alimentos por espectrometria de absorção atômica com chama. O sistema de pré-concentração baseia-se na sorção do cádmio em uma minicoluna recheada com uma…

  8. Determination of Cd in blood by microwave-induced combustion coupled to flame furnace atomic absorption spectrometry

    Lucélia Hoehne, Fabiane R. Bartz, Cezar A. Bizzi e mais 3Journal of the Brazilian Chemical Society2010

    Microwave-induced combustion system was coupled to a metallic flame furnace (FF) atomic absorption spectrometer and applied for cadmium determination in blood. Lyophilized blood samples were prepared as pellets, positioned on a quartz holder and introduced into a glass chamber used for the combustion step. The glass…

  9. Automated flow-injection method for cadmium determination with pre-concentration and reagent preparation on-line

    María S. Di Nezio, Miriam E. Palomeque e Beatriz S. Fernández BandQuímica Nova2005

    The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg…

  10. Cold vapor atomic absorption spectrometric determination of cadmium after solid phase extraction on modified TiO2 nanoparticles

    Reza Hafezi Moghaddam, Ali Mohammad Haji Shabani, Shayessteh Dadfarnia e mais 1Journal of the Brazilian Chemical Society2014

    Cadmium was quantitatively adsorbed from aqueous sample onto a microcolumn packed with cadion immobilized on sodium dodecyl sulfate-coated TiO2 nanoparticles. The retained cadmium was eluted with 2.5 mol L-1 hydrochloric acid solution and measured by cold vapor atomic absorption spectrometry (CVAAS). The influences of…

  11. Using the organofunctionalised SBA-15 nanostructured silica as a carbon paste electrode modifier: determination of cadmium ions by differential anodic pulse stripping voltammetry

    Ivana Cesarino, Glimaldo Marino, Jivaldo do Rosário Matos e mais 1Journal of the Brazilian Chemical Society2007

    The performance of a carbon paste electrode (CPE) modified with SBA-15 nanostructured silica organofunctionalised with 2-benzothiazolethiol in the determination of Cd(II) ions in natural water is described, based in a DPASV procedure. The Cd(II) oxidation peak was observed around -0.85 V (vs. SCE) in phosphate buffer…

  12. Rapid and low cost determination of cadmium in whole blood by hydride generation atomic fluorescence spectrometry after ultrasound-assisted sample preparation

    Zhongxi Li e Liping ZhouJournal of the Brazilian Chemical Society2008

    A rapid, low cost and precise method was developed for the determination of cadmium in whole blood using hydride generation atomic fluorescence (HG-AFS). Sample was simply prepared utilizing ultrasound-assisted leaching and the resulting solution was directly used for cadmium determination by HG-AFS. Adopting…

  13. Determination of cadmium by flame-atomic absorption spectrometry after preconcentration on silica gel modified with cupferron

    Gisele G. Bortoleto, Greice T. Macarovscha e Solange CadoreJournal of the Brazilian Chemical Society2004

    A method for the determination of cadmium by flame atomic absorption spectrometry (FAAS) after its preconcentration onto a column containing silica gel modified with cupferron was developed. The pH, amount of adsorbent material, concentration of eluent, volume of sample and amount of Cd were optimized. The effect of…

  14. Stripping voltammetric determination of cadmium in sea water using a carbon paste electrode modified with alginic acid from brown algae

    Carolina Muñoz, Manuel Zúñiga e Verónica ArancibiaJournal of the Brazilian Chemical Society2010

    Cadmium concentration in an aqueous medium is quantified using an alginic acid-modified carbon paste electrode. The working electrode was prepared using a homogeneous mixture of graphite powder, alginic acid (AA) and mineral oil. Square wave anodic stripping voltammetry (SWASV) using this modified electrode showed one…

  15. Field sampling system for determination of cadmium and nickel in fresh water by flame atomic absorption spectrometry

    Walter N. L. dos Santos, Carla M. dos Santos e Sérgio L. C. FerreiraJournal of the Brazilian Chemical Society2005

    A system containing Amberlite XAD - 2 (styrene-divinylbenzene copolymers) loaded with 2-(2thiazolylazo)-5-dimethylaminophenol (TAM) reagent is proposed for field sampling, preconcentration and determination of cadmium (II) and nickel (II) ions in fresh water using flame atomic absorption spectrometry (FAAS). The…

  16. Polytetrafluorethylene Membrane-Based Liquid Three-Phase Micro Extraction Combined with in situ Differential Pulse Anodic Stripping Voltammetry for the Determination of Cadmium Ions Using Au-Nanoparticles Sol-Gel Modified Pt-Wire

    Aliasghar Ensafi, Ali R. Allafchian e Behzad RezaeiJournal of the Brazilian Chemical Society2015

    In this study, one particular application of in situ pulse anodic stripping voltammetry and polytetrafluoroethylene membrane-based liquid three-phase micro extraction is presented for the micro extraction and quantification of cadmium(II) ions in trace levels. The main factors influencing on preconcentration and micro…

  17. Determination of cadmium in sediments and in sewage sludge by slurry sampling electrothermal atomic absorption spectrometry using iridium as permanent modifier

    Daniel L. G. Borges, Lúcia F. Dias, Márcia A. M. S. da Veiga e mais 1Journal of the Brazilian Chemical Society2003

    A procedure for the determination of Cd in sediment and sewage sludge as slurries by electrothermal atomic absorption spectrometry is proposed. The slurry, 1 mg mL-1, was prepared by mixing sample ground to a particle size £ 50 mm with 5% v/v nitric acid in an ultrasonic bath. The homogeneity of the slurries was…

  18. Multivariate optimization and validation of an analytical method for the determination of cadmium in wines employing ET AAS

    Sérgio L. C. Ferreira, Robson M. de Jesus, Geraldo D. Matos e mais 6Journal of the Brazilian Chemical Society2009citado por 1 artigo

    This work describes the optimization and validation of a direct method employing electrothermal atomic absorption spectrometry (ET AAS) for the determination of cadmium in wine. The optimization step was carried out using a two-level full factorial design, involving the followings factors: pyrolysis time (10 s) and…

  19. Trace determination of cadmium ions by flame atomic absorption spectrometry after pre-concentration using temperature-controlled ionic liquid dispersive-liquid phase microextraction

    Farzad Bamdad, Mehdi Ardalani e Mohammad R. SangiJournal of the Brazilian Chemical Society2014

    This paper is about an improved temperature-controlled ionic liquid dispersive liquid-phase microextraction method for pre-concentration of cadmium ions prior to determination by flame atomic absorption spectrometry. In this study, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was used as extraction…

  20. Rapid determination of cadmium residues in tomato leaves by Vis-NIR hyperspectral and Synergy interval PLS coupled Monte Carlo method

    Shupeng ZENG, Xiaohong WU, Bin WU e mais 2Food Science and Technology2023

    Abstract Excessive heavy metal cadmium in tomatoes is harmful to human health. The detection of heavy metals in tomato leaves can determine whether the heavy metals in tomatoes exceed the standard. In order to quickly, non-destructively and efficiently detect whether heavy metals on the surface of tomato leaves exceed…