acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “automatic calibration”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Use of an Automatic System in the Preparation of Gas Mixtures for Multivariate Calibration: A Case Study Involving NIR Analysis of Natural Gas

    Barbosa Barbosa, Hebertty V. Dantas, Pablo N. T. Moreira e mais 2Journal of the Brazilian Chemical Society2015

    This paper investigates the use of an automatic system for preparation of gas mixtures in a multivariate calibration problem involving near-infrared (NIR) spectrometric analysis of natural gas. The automatic system is used to prepare calibration mixtures according to a Brereton experimental design, in order to exploit…

  2. Maximum respiratory pressure measuring system: calibration and evaluation of uncertainty

    José L Ferreira, Nadja C Pereira, Marconi Oliveira Jr e mais 3Sba: Controle & Automação Sociedade Brasileira de Automatica2010citado por 4 artigos

    The objective of this paper is to present a methodology for the evaluation of uncertainties in the measurements results obtained during the calibration of a digital manovacuometer prototype (DM) with a load cell sensor pressure device incorporated. Calibration curves were obtained for both pressure sensors of the DM…

  3. Automatic calibration of a large-scale sediment model using suspended sediment concentration, water quality, and remote sensing data

    Hugo de Oliveira Fagundes, Fernando Mainardi Fan e Rodrigo Cauduro Dias de PaivaRBRH2019citado por 1 artigo

    ABSTRACT Calibration and validation are two important steps in the application of sediment models requiring observed data. This study aims to investigate the potential use of suspended sediment concentration (SSC), water quality and remote sensing data to calibrate and validate a large-scale sediment model. Observed…

  4. Development, sensitivity and uncertainty analysis of LASH model

    Samuel Beskow, Carlos Rogério de Mello e Lloyd Darrell NortonScientia Agricola2011citado por 5 artigos

    Many hydrologic models have been developed to help manage natural resources all over the world. Nevertheless, most models have presented a high complexity regarding data base requirements, as well as, many calibration parameters. This has brought serious difficulties for applying them in watersheds where there is…

  5. Error identification and compensation in large manipulators with application in cancer proton therapy

    M.A. Meggiolaro, S. Dubowsky e C. MavroidisSba: Controle & Automação Sociedade Brasileira de Automatica2004

    Important robotic tasks could be effectively performed by powerful and accurate manipulators. However, high accuracy is generally difficult to obtain in large manipulators capable of producing high forces due to system elastic and geometric distortions. A method is presented to identify the sources of end-effector…

  6. Sampling strategies to estimate suspended sediment concentration for turbidimeter calibration

    Leandro Dalbianco, Rafael Ramon, Claudia A. P. de Barros e mais 3Revista Brasileira de Engenharia Agrícola e Ambiental2017

    ABSTRACT The influx of sediments carried by rivers can be measured continuously using a turbidimeter through the indirect relationship between turbidity and suspended sediment concentration (SSC). However, this process is dependent on obtaining water samples with suspended sediments to calibrate the turbidimeter…

  7. A simple interferometric method to measure the calibration factor and displacement amplification in piezoelectric flextensional actuators

    Francisco de Assis Andrade Barbosa, Gilder Nader, Ricardo Tokio Higuti e mais 2Sba: Controle & Automação Sociedade Brasileira de Automatica2010

    Laser interferometry is a well-established technique for the characterization of piezoelectric actuators. In this work, by using a low cost Michelson interferometer, the measurement of the calibration factor and the displacement amplification of a novel piezoelectric flextensional actuator (PFA), designed by using the…