acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “amperometric biosensor”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Development of a New Amperometric Biosensor for Lactose Determination

    R.J.M. Lourenço, M.L.M. Serralheiro e M.J.F. RebeloPortugaliae Electrochimica Acta2003

    A new amperometric biosensor for lactose determinaion in raw milk was developed through the simultaneous immobilization of β-galactosidase and galactose oxidase on a derivatised polyethersulphone membrane. β-galactosidase catalyses the hydrolysis of lactose into galactose and glucose and galactose oxidase catalyses…

  2. Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures

    Pablo A. Fiorito e Susana I. Córdoba de TorresiJournal of the Brazilian Chemical Society2001

    The co-immobilization of GOx and ferrocene in a polymeric matrix by a one-step simple method is presented. This procedure to immobilize ferrocene as mediator implies the absence of modification of the monomer or the enzyme that would lead to the loss of its activity. Ferrocene incorporation results in an increase of…

  3. Amperometric enzyme electrodes

    E.J. Calvo e C. DanilowiczJournal of the Brazilian Chemical Society1997

    Recent advances on amperometric enzyme electrodes are reviewed with particular emphasis on biosensors based on Glucose Oxidase and Horseradish Peroxidase. Redox mediation by artificial soluble and polymer attached redox mediators is discussed in terms of recent theoretical developments and experimental verification…

  4. Amperometric biosensor for ascorbic acid

    I. N. Tomita, A. Manzoli, F. L. Fertonani e mais 1Eclética Química2005citado por 1 artigo

    A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto…

  5. Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices

    Renato S. Freire, Nelson Durán e Lauro T. KubotaJournal of the Brazilian Chemical Society2002

    A flow system method for continuous determination of phenolic compounds in environmental matrices was employed using a dialysis membrane sampler and laccase- and tyrosinase-based biosensors as detector. The biosensors response to different phenolic compounds was investigated. The laccase-based biosensor showed high…

  6. Microbial biosensor for assessment of drug supplements containing L-tryptophan based on dissolved oxygen detection

    Lazuardi Umar, Rahmondia Nanda Setiadi, Tetty Marta Linda e mais 1Brazilian Journal of Food Technology2025

    Abstract The amino acid L-tryptophan (L-Trp) can overcome several mental stress problems, serotonin syndrome, and neurological disorders; however, L-Trp can only be obtained from raw food and certain essential supplements. This study aims to detect L-tryptophan in several commercial dietary supplements using a…

  7. Optimization of an amperometric biosensor for the detection of hepatitis C virus using fractional factorial designs

    Carolina V. Uliana, Carla S. Riccardi, João O. Tognolli e mais 1Journal of the Brazilian Chemical Society2008

    Fractional factorial design and factorial with center point design were applied to the development of an amperometric biosensor for the detection of the hepatitis C virus. Biomolecules were immobilized by adsorption on graphite electrodes modified with siloxane-poly(propyleneoxide) hybrid matrix prepared using the…

  8. On the Use of a TiO2 Sol-Gel for Horseradish Peroxidase Enzyme Immobilization for Development of an Amperometric Biosensor

    Carolina G. da Rocha, Carolina V Uliana e Hideko YamanakaJournal of the Brazilian Chemical Society2021

    The sol-gel technique has drawn considerable attention in the area of biomolecules immobilization by virtue of its intrinsic properties including chemical inertness, thermal stability, and good biocompatibility. The present work reports the development of a bio-sensing methodology which involves the immobilization of…

  9. A biosensor based on immobilization of lactate oxidase in a PB-CTAB film for FIA determination of lactate in beer samples

    Denise Lowinsohn e Mauro BertottiJournal of the Brazilian Chemical Society2008

    An amperometric lactate biosensor with lactate oxidase immobilized into a Prussian Blue (PB) modified electrode was fabricated. The advantage of using cetyltrimethylammonium bromide (CTAB) in the electrodeposition step of PB films onto glassy carbon surfaces was confirmed taking into account both the stability and…

  10. Enzymeless biosensors: uma nova área para o desenvolvimento de sensores amperométricos

    Maria Del Pilar Taboada Sotomayor e Lauro Tatsuo KubotaQuímica Nova2002

    The aim of this work is to describe the recent area that it has been developed for the construction of amperometric sensors, with the purpose to make possible a more effective electron transfer between enzyme and electrode. The advances reported in the literature will be described, such as enzymatic configurations…

  11. Development of an amperometric enzyme electrode based on poly(o-phenylenediamine) for the determination of total cholesterol in serum

    Derya Koyuncu Zeybek, Bülent Zeybek, Nuran Özçiçek Pekmez e mais 2Journal of the Brazilian Chemical Society2012

    A polymer-based amperometric enzyme electrode (Pt/PoPD/ChOx) was prepared for the amperometric detection of free cholesterol. Firstly, poly(o-phenylenediamine) (PoPD) polymer film was prepared in acetonitrile-water medium containing o-phenylenediamine (oPD) monomer and (±)-10-camphorsulfonic acid (HCSA) on Pt…