acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “amperometric”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. AMPEROMETRIC DETERMINATION OF 8-CHLOROTHEOPHYLLINE, CAFFEINE, AND DIPHENHYDRAMINE IN A SINGLE RUN

    Jhonys Machado Freitas, Thiago da Costa Oliveira, Rodrigo Alejandro Abarza Munoz e mais 1Química Nova2017

    A simple method for simultaneous determination of 8-chlorotheophylline (CTP), caffeine (CAF), and diphenhydramine (DIP) using batch-injection analysis with multiple pulse amperometric detection (BIA-MPA) is reported. A sequence of three potential pulses (+1.10 V, +1.40 V, and +1.70 V) was applied to the boron-doped…

  2. Manganese phthalocyanine as a biomimetic electrocatalyst for phenols in the development of an amperometric sensor

    Wilney de Jesus R. Santos, Aline L. Sousa, Maria del Pilar T. Sotomayor e mais 4Journal of the Brazilian Chemical Society2009

    The construction of an amperometric sensor for phenolic compounds using a carbon paste electrode modified with manganese phthalocyanine and histidine is reported. Under optimized conditions, at 0 mV vs Ag/AgCl in 0.1 mol dm-3 phosphate buffer solutions (pH 7.0) containing 250 µmol dm-3 H2O2, a linear response for…

  3. Simple flow injection amperometric system for simultaneous determination of dipyrone and paracetamol in pharmaceutical formulations

    Wallans T. P. dos Santos, Denise T. Gimenes, Edimar G. N. de Almeida e mais 3Journal of the Brazilian Chemical Society2009

    In this work a simple flow injection methodology with pulsed amperometric detection for simultaneous determination of dipyrone (DI) and paracetamol (PCT) in pharmaceutical formulations is described. The compounds are detected by applying four sequential potential pulses as function of the time. Dipyrone is directly…

  4. Study of the electrochemical reduction of amoebicide teclozan and its amperometric determination in pharmaceutical formulations

    André L. Santos, Regina M. Takeuchi, Nelson R. Stradiotto e mais 2Journal of the Brazilian Chemical Society2008

    The electrochemical reduction of amoebicide Teclozan (TEC) was studied on a glassy carbon electrode in acetonitrile. Controlled-potential electrolyses were performed for coulometric and preparative purposes. The electrogenerated products were isolated by liquid-liquid extraction and characterized by ¹H NMR. It was…

  5. Evaluation of gas diffusion electrodes as detectors in amperometric hydrogen sensors

    W. H. Lizcano-Valbuena, J. Perez, V. A. Paganin e mais 1Eclética Química2005

    This work is directed to the study and evaluation of gas diffusion electrodes as detectors in hydrogen sensors. Electrochemical experiments were carried out with rotating disk electrodes with a thin porous coating of the catalyst as a previous step to select useful parameters for the sensor. An experimental…

  6. Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto

    M. Beatriz Quinaz Garcia, José L.F.C. Lima, M. Luísa Silva e mais 1Portugaliae Electrochimica Acta2004

    This paper describes the use of a FIA system for the automatic determination of uric acid in urine, using a tubular amperometric detector. In this system, glassy carbon electrodes of tubular configuration were activated by successive cyclical scans from - 0.30 to 2.00 V versus Ag/AgCl reference electrode in 0.50…

  7. Development of a New Amperometric Biosensor for Lactose Determination

    R.J.M. Lourenço, M.L.M. Serralheiro e M.J.F. RebeloPortugaliae Electrochimica Acta2003

    A new amperometric biosensor for lactose determinaion in raw milk was developed through the simultaneous immobilization of β-galactosidase and galactose oxidase on a derivatised polyethersulphone membrane. β-galactosidase catalyses the hydrolysis of lactose into galactose and glucose and galactose oxidase catalyses…

  8. Glucose Amperometric Biosensor Based on the Co-immobilization of Glucose Oxidase (GOx) and Ferrocene in Poly(pyrrole) Generated from Ethanol / Water Mixtures

    Pablo A. Fiorito e Susana I. Córdoba de TorresiJournal of the Brazilian Chemical Society2001

    The co-immobilization of GOx and ferrocene in a polymeric matrix by a one-step simple method is presented. This procedure to immobilize ferrocene as mediator implies the absence of modification of the monomer or the enzyme that would lead to the loss of its activity. Ferrocene incorporation results in an increase of…

  9. Amperometric enzyme electrodes

    E.J. Calvo e C. DanilowiczJournal of the Brazilian Chemical Society1997

    Recent advances on amperometric enzyme electrodes are reviewed with particular emphasis on biosensors based on Glucose Oxidase and Horseradish Peroxidase. Redox mediation by artificial soluble and polymer attached redox mediators is discussed in terms of recent theoretical developments and experimental verification…

  10. DEVICE FOR CALIBRATING ELECTROCHEMICAL DISSOLVED OXYGEN SENSORS

    Marcus L. Sousa, Isabela A. Duran, Giovana V. Teixeira e mais 1Química Nova2025

    Sensor calibration for dissolved gas is a critical and necessary step to ensure consistent sensor response over time and under different conditions. In this work, we describe a 3D printed device that facilitates the calibration of gas sensors. The device effectively maintained gas concentration in the solution for at…

  11. Microbial biosensor for assessment of drug supplements containing L-tryptophan based on dissolved oxygen detection

    Lazuardi Umar, Rahmondia Nanda Setiadi, Tetty Marta Linda e mais 1Brazilian Journal of Food Technology2025

    Abstract The amino acid L-tryptophan (L-Trp) can overcome several mental stress problems, serotonin syndrome, and neurological disorders; however, L-Trp can only be obtained from raw food and certain essential supplements. This study aims to detect L-tryptophan in several commercial dietary supplements using a…

  12. On the Use of a TiO2 Sol-Gel for Horseradish Peroxidase Enzyme Immobilization for Development of an Amperometric Biosensor

    Carolina G. da Rocha, Carolina V Uliana e Hideko YamanakaJournal of the Brazilian Chemical Society2021

    The sol-gel technique has drawn considerable attention in the area of biomolecules immobilization by virtue of its intrinsic properties including chemical inertness, thermal stability, and good biocompatibility. The present work reports the development of a bio-sensing methodology which involves the immobilization of…

  13. Evaluation of a Graphite-Polyurethane Composite Electrode Modified with Copper Nanoparticles as an Amperometric Flow Detector in a Wall-Jet System for the Determination of Cysteine

    Isabela A. Mattioli, Letícia F. L. Schildt, Priscila Cervini e mais 2Journal of the Brazilian Chemical Society2020

    A graphite-polyurethane composite electrode (GPUE) was modified by electrodeposition of copper nanoparticles (CuNP) followed by electrochemical treatment in NaOH (GPUE-CuNP), in order to prepare an amperometric sensor for the determination of cysteine (Cys). Cyclic votammograms of Cys solutions at GPUE-CuNP allowed…

  14. New Detector Based on Composite of Carbon Nanotubes with Nanoparticles of Cobalt Oxide for Carbohydrates Analysis by HPLC with Reverse Pulsed Amperometric Detection

    Acelino C. de Sá, Leonardo L. Paim e Nelson R. StradiottoJournal of the Brazilian Chemical Society2020

    This work aims to present an alternative detector for the determination of arabinose, galactose, glucose and xylose in hydrolyzed sugarcane bagasse. The detector was developed using an electrode modified with multi-walled carbon nanotubes containing cobalt oxide nanoparticles (GCE/MWCNT/CoOOH) applied in…

  15. Evaluation of Carbon Nanotubes/Polyaniline Thin Films for Development of Electrochemical Sensors

    Fabio S. Lisboa, Eduardo G. C. Neiva, Marcio F. Bergamini e mais 2Journal of the Brazilian Chemical Society2020

    Thin films of multiwalled carbon nanotubes/polyaniline nanocomposites (CNT/PAni) were synthesized through the liquid/liquid (L/L) interfacial route, deposited over glass substrates, and evaluated through cyclic voltammetry and amperometry as electrochemical sensor, using L-ascorbic acid as probe. Films with three…

  16. Determination of Colchicine in Pharmaceutical Formulations and Urine by Multiple-Pulse Amperometric Detection in an FIA System Using Boron-Doped Diamond Electrode

    Débora A. R. Moreira, Fernando M. de Oliveira, Dilton M. Pimentel e mais 6Journal of the Brazilian Chemical Society2018

    This work presents a simple and fast method for colchicine (CO) determination in pharmaceutical formulations and urine by multiple pulse amperometry (MPA) with flow injection analysis (FIA) system using a boron-doped diamond electrode. In optimized conditions, it was possible to quantify CO in urine samples without…

  17. Amperometric Electrochemical Platform for Hydrazine Determination Exploiting Reduced Graphene Oxide, Co(Salophen) and DNA: Application in Pharmaceutical Formulations Samples

    Ludymila V. Freitas, Kayni C. M. S. Lima, Saimon M. Silva e mais 5Journal of the Brazilian Chemical Society2018

    The present work presents the development of a sensitive and selective amperometric sensor for the determination of hydrazine (HZ) in pharmaceutical formulations using a glassy carbon electrode (GCE) modified with a composite based on Co(Salophen), reduced graphene oxide (rGO) and deoxyribonucleic acid (DNA). The…

  18. Batch-Injection Amperometric Determination of Pyrogallol in Biodiesel Using a Multi-Walled Carbon Nanotube Modified Electrode

    Rafael M. Cardoso, Rafael M. Dornellas, Ana P. Lima e mais 3Journal of the Brazilian Chemical Society2017citado por 1 artigo

    This work demonstrates the application of batch-injection analysis (BIA) with amperometric detection on a multi-walled carbon nanotube (MWCNT) modified electrode for the sensitive determination of the antioxidant pyrogallol in biodiesel. Samples were diluted in electrolyte (0.1 mol L-1 HClO4) before injection using an…

  19. Selective Determination of Unsymmetrical Dimethylhydrazine on a Prussian Blue Modified Carbon Paste Electrode

    Bagher Sobhanmanesh e Mostafa NajafiJournal of the Brazilian Chemical Society2015

    The electrocatalytic oxidation of unsymmetrical dimethylhydrazine (UDMH) has been studied on a Prussian Blue modified carbon paste electrode (PBMCPE) by cyclic voltammetry technique. The results show that Prussian Blue acts as a suitable modifier for electron transfer in the oxidation of UDMH. A linear range of 3 ×…