acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “William Cunha Brandt”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Zirconia abutments and reduced crown-to-implant ratios: Insights into stress distribution

    Lorenzo GRASSI, Ayrton Geroncio SILVA, Guilherme Almeida BORGES e mais 5Brazilian Oral Research2026

    Abstract This study aims to evaluate stress distributions in dental implants, zirconia abutments, and peri-implant bone tissues at different crown-to-implant ratios. In-silico analysis was performed using SolidWorks (SolidWorks Corporation, Concord) to evaluate stress distributions in the implant and abutment based on…

  2. Nanotopography and oral bacterial adhesion on titanium surfaces: in vitro and in vivo studies

    Humberto Osvaldo SCHWARTZ-FILHO, Tauane Ramaldes MARTINS, Paulo Roberto SANO e mais 8Brazilian Oral Research2024citado por 1 artigo

    Abstract The present study aimed to evaluate the influence of titanium surface nanotopography on the initial bacterial adhesion process by in vivo and in vitro study models. Titanium disks were produced and characterized according to their surface topography: machined (Ti-M), microtopography (Ti-Micro), and…

  3. Antimicrobial activity of PMMA enriched with nano-clay loaded with metronidazole and chlorhexidine

    Eduardo Buozi Moffa, Samuel Santana Malheiros, Larissa Tavares Sampaio Silva e mais 6Brazilian Oral Research2024

    Abstract Poly(methyl methacrylate) (PMMA) materials are highly susceptible to microbial colonization, predisposing patients to oral infections. To address this concern, we loaded PMMA samples with montmorillonite clay (MMT), a crystalline nanoparticle, in combination with chlorhexidine (CHX) or metronidazole (MET)…

  4. Microtensile bond strength of resin composite to dentin using different adhesive systems and directions of electric current

    Maurício Bottene Guarda, Rafael Rocha Pacheco, Isaias Donizeti Silva e mais 3Brazilian Dental Journal2022

    Resumo O objetivo neste estudo foi avaliar o efeito da direção da corrente elétrica na resistência da união resina composta-dentina usando três sistemas adesivos. Dentes molares humanos foram distribuídos de acordo com o sistema adesivo (dois passos autocondicionante - Clearfil SE Bond, Kuraray [CSE]; e um passo…

  5. Light-Curing Units, Photoinitiators System, and Monomers on Physico-Mechanical Properties of Experimental Composite Resins

    Gustavo Furlan da Silva Prezotto, Weverteon Soares de Lima, Rafael Pino Vitti e mais 3Matéria (Rio de Janeiro)2020citado por 1 artigo

    ABSTRACT This study evaluated the physico-mechanical properties of experimental composite resins made with different resin matrix and light-curing units. Experimental composite groups were divided according to monomers (BisGMA + TEGDMA-BT and BisGMA + BisEMA + UDMA + TEGDMA-BBUT) and photoinitiator system…

  6. Polymerization depths of conventional and bulk fill composites photoactivated by different methods

    Willian Fernando Felipe, Weverteon Soares de Oliveira, Milton Edson Miranda e mais 3Matéria (Rio de Janeiro)2020citado por 1 artigo

    ABSTRACT The aim of this study was to evaluate the depth of cure of conventional (Filtek Z350 and Esthet-X HD) and bulk fill resins composites (Filtek bulk fill flow and SDR) using different photoactivation methods. Samples were made using five disc-shaped matrices (1 mm high and 8 mm central diameter) with interposed…

  7. Effect of Glass Fiber Post Adaptation on Push-Out Bond Strength to Root Dentin

    Thiago Lopes de Freitas, Rafael Pino Vitti, Milton Edson Miranda e mais 1Brazilian Dental Journal2019citado por 6 artigos

    Abstract The aim of this study was to evaluate the effect of different glass fiber posts (GFPs) diameters on the push-out bond strength to dentin. Forty unirradicular human teeth were endodontically treated and used for cementation of GFPs (White Post DC, FGM) with different diameters (n=10): P1 - ø 1.6 mm coronal x…

  8. Influence of Different Concentration and Ratio of a Photoinitiator System on the Properties of Experimental Resin Composites

    Caio Vinícius Signorelli Grohmann, Eveline Freitas Soares, Eduardo José Carvalho Souza-Junior e mais 4Brazilian Dental Journal2017citado por 1 artigo

    Abstract The aim in this study was to evaluate the influence of different ratio of camphorquinone/tertiary amine concentration on the flexural strength (FS), elastic modulus (EM), degree of conversion (DC), yellowing (YL), water sorption (WS) and water solubility (WSL) of experimental composites. Thus, acrylate blends…

  9. Dimensional accuracy of different impression techniques of partially edentulous mandibular arch

    Rafael Pino VITTI, Victor Pinheiro FEITOSA, Ataís BACCHI e mais 3RGO - Revista Gaúcha de Odontologia2017

    ABSTRACT Objective: The purpose of this in vitro study was to assess and compare the dimensional accuracy of three impression techniques: 1-step putty/light-body, 2-step putty/light-body, and the monophase technique. Methods: A partially edentulous standard stainless steel mandibular arch cast with reference points on…

  10. Influence of Photoinitiator and Light-Curing Source on Bond Strength of Experimental Resin Cements to Dentin

    Dario Raimundo Segreto, Fabiana Scarparo Naufel, William Cunha Brandt e mais 3Brazilian Dental Journal2016citado por 6 artigos

    Abstract This study evaluated the bond strength (BS) of experimental resin cements formulated with different photoinitiators when activated by two kinds of light-curing units (LCUs) through a ceramic material. Seven resin blends with different camphorquinone (CQ) and/or phenylpropanedione (PPD) concentrations (weight)…

  11. Evaluation of phenyl-propanedione on yellowing and chemical-mechanical properties of experimental dental resin-based materials

    Dayane Carvalho Ramos Salles de OLIVEIRA, Eduardo José SOUZA-JUNIOR, Adam DOBSON e mais 3Journal of Applied Oral Science2016citado por 1 artigo

    ABSTRACT Objective To evaluate the influence of phenyl-propanedione on yellowing and chemical-mechanical properties of experimental resin-based materials photoactivated using different light curing units (LCUs). Material and Methods Experimental resin-based materials with the same organic matrix (60:40 wt%…

  12. Photoelastic evaluation of the effect of composite formulation on polymerization shrinkage stress

    Karla Mychellyne Costa Oliveira, Simonides Consani, Luciano Souza Gonçalves e mais 2Brazilian Oral Research2012citado por 3 artigos

    We compared polymerization stress in two commercial composites and three experimental composites made using camphorquinone (CQ) and/or phenylpropanedione (PPD) as photoinitiators. The internal surfaces of photoelastic resin discs with cylindrical cavities were roughened and treated with adhesive. Composites were…

  13. Effect of different photo-initiators and light curing units on degree of conversion of composites

    William Cunha Brandt, Luis Felipe Jochims Schneider, Elisabete Frollini e mais 2Brazilian Oral Research2010citado por 9 artigos

    The aim of this study was to evaluate: (i) the absorption of photo-initiators and emission spectra of light curing units (LCUs); and (ii) the degree of conversion (DC) of experimental composites formulated with different photo-initiators when activated by different LCUs. Blends of BisGMA, UDMA, BisEMA and TEGDMA with…

  14. In vitro toothbrushing abrasion of dental resin composites: packable, microhybrid, nanohybrid and microfilled materials

    Rafael Ratto de Moraes, Daiane dos Santos Ribeiro, Mirian Margarete Klumb e mais 3Brazilian Oral Research2008citado por 4 artigos

    This study evaluated weight loss and surface roughening after toothbrushing of different resin composites: one packable (Solitaire 2, Heraeus Kulzer), one microhybrid (Charisma, Heraeus Kulzer), one nanohybrid (Simile, Pentron) and one microfilled (Durafill VS, Heraeus Kulzer). Cylindrical specimens (n = 20) were…