acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Urine”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Mehdi Maham, Vahid Kiarostami, Syed Waqif-Husain e mais 1Brazilian Journal of Pharmaceutical Sciences2014citado por 1 artigo

    A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM), an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME) followed by high performance liquid chromatography with diode array detection (HPLC-DAD). In this…

  2. Simultaneous determination of rifampicinand isoniazid in urineand pharmaceutical formulations by multivariate visible spectrophotometry

    Sandra Stets, Talita M. Tavares, Patricio G. Peralta-Zamora e mais 2Journal of the Brazilian Chemical Society2013

    Partial least squares regression (PLSR) was used for the simultaneous quantification of rifampicin (RIF)and isoniazid (INH) by visible spectrophotometry using a simple derivatization reaction. In the presence of neocuproine, copper(II) is easily reduced by INH to a Cu(I)-neocuproine complex that shows an absorption…

  3. Diagnosis of spontaneous bacterial peritonitis in cirrhotic patients in northeastern Brazil by use of rapid urine-screening test

    Lucia Libanez Bessa Campelo Braga, Marcellus Henrique Loiola Ponte de Souza, Alzira Maria de Castro Barbosa e mais 3Sao Paulo Medical Journal2006

    CONTEXT AND OBJECTIVE: Spontaneous bacterial peritonitis (SBP) is a frequent and severe complication of cirrhotic patients with ascites. It has been proposed that the reagent strip for leukocyte esterase designed for the testing of urine (Combur test® UX) could be a useful tool for diagnosing SPB. The aim of this…

  4. Effects of selective serotonin and norepinephrine reuptake inhibitor (Venlafaxine) in urine marking behavior in castrated male cats

    J. Jalalifar, S. Mashhadyrafie e B. VazirArquivo Brasileiro de Medicina Veterinária e Zootecnia2025

    ABSTRACT To evaluate the effectiveness of a selective serotonin and norepinephrine reuptake inhibitor (SSNRI), Venlafaxine was used to alleviate problem urine marking in castrated male cats. Randomized placebo-controlled trial double-blind clinical trial. Twenty castrated male cats more than one-year-old objectionable…

  5. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode

    Mohamed Omar, Carl Sarkissian, Li Jianbo e mais 2International braz j urol2016

    ABSTRACT Objectives To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. Materials and Methods We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent…

  6. Comparative study of spot urine Na/K ratio and 24-hour urine sodium in natriuresis evaluation of cirrhotic patients with ascites

    Otávio Marcos da Silva, Gabriela Bicca Thiele, Leonardo Fayad e mais 4Jornal Português de Gastrenterologia2014

    Introduction: The ‘‘spot’’ urine sodium/potassium (Na/Ku) ratio is a convenient tool to identify sodium excretion < 78 mequiv./d. It has been established that this ratio is as useful and accurate as 24-h urine sodium (Nau24h), but no Latin American study has evaluated this issue. The aim of this study is to evaluate…

  7. Resveratrol improves behavior and neurochemical parameters in rats submitted to a Maple Syrup Urine Disease chemical model

    PAULINE S. EFFTING, ISABELA S. LEMOS, BIANCA Z. DE MEDEIROS e mais 8Anais da Academia Brasileira de Ciências2026

    Abstract Maple syrup urine disease (MSUD) is a rare genetic disorder characterized by a deficiency of the branched-chain α-keto acid dehydrogenase enzyme complex, resulting in the accumulation of branched-chain amino acids (BCAA) in the tissues and body fluids of patients. Metabolic decompensation plays a central role…

  8. NMR-Based Urine Metabolic Profiling of Cri-du-Chat Syndrome

    Glenda S. de Oliveira, Danielle Z. S. Furtado, Elenilson G. Alves Filho e mais 4Journal of the Brazilian Chemical Society2026

    Cri-du-chat syndrome (CDCS) is a rare genetic disorder caused by a partial deletion of chromosome 5. Common features include intellectual disability, developmental delays, microcephaly, and a characteristic high-pitched cry. Although CDCS has been extensively studied from genetic and developmental perspectives, its…

  9. Untargeted Metabolomics of Dried Urine Spot Samples from Pompe Disease Patients

    Hygor M. R. de Souza, Clarisse L. Torres, Fernanda B. Scalco e mais 2Journal of the Brazilian Chemical Society2026

    Dried blood samples on filter paper have been used in newborn screening programs for decades and have recently gained attention as a practical alternative to traditional liquid matrices for untargeted metabolomics. This material provides benefits, such as long-term stability and cost-effective transportation, which…

  10. Study of Organic Acids Profile in Human Urine by Capillary Zone Electrophoresis Aiming at the Diagnosis of COVID-19

    Olívia B. O. Moreira, Luiz H. C. Adriano, Patrícia A. Geraldo e mais 13Journal of the Brazilian Chemical Society2026

    The coronavirus disease (COVID-19) pandemic highlighted the need for alternative diagnostic strategies based on accessible and non-invasive technologies. This proof-of-concept study evaluates capillary zone electrophoresis with ultraviolet detection as a data-acquisition platform for exploratory profiling of four…

  11. Evaluation and comparison of voided urine and bladder washing cytologies according to the Paris system

    Asiye Şafak Bulut e Yalçın KızılkanRevista da Associação Médica Brasileira2026

    SUMMARY OBJECTIVE: Cystoscopy, biopsy, and urine cytology are gold standards for the diagnosis and surveillance of bladder carcinoma. Bladder washings, obtained via cystoscopy or by catheterization, are common in routine cytology practice, whereas voided urine is evaluated less frequently. The aim of this study was to…

  12. Sensitive Determination of Bisphenol A In Urine Using Automated Solid-Phase Extraction Followed by LC-MS/MS Analysis: Application to a Human Biomonitoring Study in Brazil

    Camila F. de Souza, Giovana P. Peteffi, Cloé D. Loredo e mais 8Journal of the Brazilian Chemical Society2025

    Bisphenol A (BPA), an endocrine disruptor present mostly in polycarbonate plastics and epoxy resins, can migrate into food and beverages, resulting in human exposure. This study aimed to develop and validate an improved liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method for measuring BPA levels in urine…

  13. Biomonitoring of Parabens in South Brazilian Urine Samples: A Validated SPE-LC-MS/MS Method

    Cloé D. Loredo, Giovana P. Peteffi, Camila F. de Souza e mais 5Journal of the Brazilian Chemical Society2025

    This study describes a method for the simultaneous parabens (PBs) quantification in 100 urine volunteers residing in Southern Brazil, using a three-step solid-phase extraction (SPE) with hydrophilic-lipophilic balance (HLB®) sorbent, with subsequent analysis by liquid chromatography-tandem mass spectrometry…

  14. A machine learning approach towards endometriosis screening using infrared spectra of urine

    Matthews Silva Martins, Gabriela Barros Valente, Yasmin do Nascimento Pedra e mais 6Clinics2025

    Abstract Background Endometriosis diagnosis is challenging due to non-specific symptoms that overlap with other gynaecological conditions. This study proposes a non-invasive Machine Learning (ML) ‒ based urine test using Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectroscopy for rapid…

  15. Self-sampling for HPV genotyping: a study of vaginal and urine collection in Brazilian women with high-grade lesions

    Cristina Paula Castanheira, Noely Paula Cristina Lorenzi, Fernanda Dahrouge Chiarot e mais 8Clinics2025citado por 2 artigos

    Abstract Objective In Brazil — a country of continental dimensions with marked socioeconomic disparities — the use of self-collected samples and first-void urine for cervical cancer screening may be particularly valuable. This study aimed to assess the acceptability of two self-sampling approaches - first-void urine…

  16. Determination of benzene, toluene, ethylbenzene, p-, m-, o-xylene, and n-butyl acetate in urine by a validated gas chromatography method: Application to an occupational monitoring study

    Emrah Dural, Betül İşiner Kaya, Görkem Mergen e mais 2Brazilian Journal of Pharmaceutical Sciences2025

    Abstract This study was aimed to determine occupational and non-occupational exposure to benzene, toluene p-m-o-xylene (BTEXs) and butyl-acetate (nBA). The aim of this work was to develop a simple, sensitive, and reliable chromatographic method using urine, a non-invasive human sample. The method was applied to…

  17. Evaluation of adherence to tenofovir treatment by hiv patients using drug concentrations in urine and standardized questionnaires

    Rafaela Knak dos Santos, Gessica Carpes Reginatto, Amanda Pacheco Bondan e mais 6Brazilian Journal of Pharmaceutical Sciences2025

    Adherence to tenofovir-based antiretroviral therapy is crucial for treatment success. In this study, we evaluated tenofovir urine concentrations in a cohort of patients that answered standardized adherence questionnaires Morisky-Green and Brief Medication Questionnaire (BMQ). Adherence evaluations were related to the…

  18. Prevalence and antimicrobial resistance profile of pathogens isolated from patients with urine tract infections admitted to a university hospital in a medium-sized Brazilian city

    Mariana Negri, Bárbara Martins Lima, Renata dos Santos Batista Reis Woloszynek e mais 5Revista do Instituto de Medicina Tropical de São Paulo2024

    ABSTRACT This study aimed to determine the antibiotic profile of microorganisms isolated from urine samples of patients with community urine tract infections (UTI) admitted to the University Hospital of the Federal University of Sao Carlos to support an appropriate local empirical treatment. A retrospective…

  19. Human papillomavirus DNA testing with the urine sample is not yet available: the accuracy of two distinct kits

    Ferah Kazanci, Ozlem Erdem, Mehmet Anil Onan e mais 1Revista da Associação Médica Brasileira2024

    SUMMARY OBJECTIVE: The aim of this study was to assess the results and efficiency of two real-time polymerase chain reaction procedures for detecting human papillomavirus utilizing urine samples. METHODS: This study comprised 151 patients who had previously tested positive for human papillomavirus in their cervical…

  20. Albumin-to-protein ratio in spot urine samples for analysis of proteinuria selectivity in chronic kidney disease

    Miguel Augusto Martins Pereira, Roger Freitas Ramirez Jordan, Jorge Paulo Strogoff de Matos e mais 1Brazilian Journal of Nephrology2023

    ABSTRACT Introduction: The albumin-to-creatinine ratio and total protein-to-creatinine ratio in spot urine samples have already been validated as surrogates for 24-hour albuminuria and proteinuria measurements. Thus, we hypothesized that the type of proteinuria, detected by the electrophoretic pattern of 24-hour…