  1. Enhancement the Fatigue Life of Floating Breakwater Mooring System Using Tuned Liquid Column Damper

    Mostafa Shahrabi e Khosrow BargiLatin American Journal of Solids and Structures2019citado por 1 artigo

    Abstract Safety is a key design criterion for floating structures. A high rate of mooring accidents has been reported over the past decades. Preventing mooring line failure is a key design objective for floating breakwater systems. The mooring system comprises sets of mooring lines anchored to the seabed. These…

  2. Analysis of a tuned liquid column damper in non-linear structures subjected to seismic excitations

    Gilda Espinoza, Carlos Carrillo e Alvaro SuazoLatin American Journal of Solids and Structures2018citado por 3 artigos

    Abstract The behavior of the tuned liquid column damper (TLCD) is analyzed in the control of non-linear structures subjected to random seismic excitations. The structure is modeled as a system of one degree of freedom with incursion in the non-linear range. The Bouc-Wen hysteretic model is used to model the non-linear…

  3. Influence of the excitation frequency content on the efficiency of a tuned liquid column damper

    G. Espinoza, C. Romero e F. BenedettiLatin American Journal of Solids and Structures2021

    Abstract The current study addresses the influence of the excitation frequency content on the efficiency of a tuned liquid column damper (TLCD) to control the displacement response in structures subjected to seismic excitations. A time-domain stochastic stationary analysis is performed, and an equivalent statistical…

  4. Effects of soil-structure interaction in seismic analysis of buildings with multiple pressurized tuned liquid column dampers

    Maurício Vitali Mendes, Paulo Marcelo Vieira Ribeiro e Lineu José PedrosoLatin American Journal of Solids and Structures2019citado por 1 artigo

    Abstract In this paper soil-structure interaction (SSI) effects are investigated while an array of Pressurized Tuned Liquid Column Dampers (PTLCD) is employed for seismic vibration control of buildings. This device represents the most general case of a passive damper, with different reduction options to other control…

  5. Tuned Liquid Column Dampers under Stochastic Excitation with Viscosity and Geometric Effects

    M. O. SILVA, J. O. MAUPRIVEZ, F. L. C. SILVA e mais 2Trends in Computational and Applied Mathematics2026

    ABSTRACT Tuned Liquid Column Dampers (TLCDs) are recognized for their effectiveness in passive vibration control. However, accurately modeling their damping characteristics remains a challenge due to the complex, nonlinear dependence of head loss on fluid properties and flow regimes. This study presents a numerical…

  6. A study of TLCD parameters for structural vibration mitigation

    Maurício Vitali Mendes, Lucas Borchardt Ghedini, Rafael Neponuceno Batista e mais 1Latin American Journal of Solids and Structures2023

    Abstract In this article, the efficiency of the tuned liquid column damper (TLCD) in reducing structural vibration is analyzed. The analysis by numerical methods and by analytical methods is adopted in the search for the ideal parameters for the liquid column. The equivalent linear model is considered for the U-shaped…