acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Titanium implants”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Surface characterization of titanium Based dental implants

    Guilherme A. A. Castilho, Maximiliano D. Martins e Waldemar A. A. MacedoBrazilian Journal of Physics2006citado por 6 artigos

    The study of dental implant surfaces is relevant in order to better understand the interaction of the titanium surface and the surrounding tissues. Clinical success is achieved not only because of implant material but also because of other properties as implant design, surface treatment and quality. In this work, we…

  2. Electrochemical behavior of three CP titanium dental implants in artificial saliva

    Norma Terumi Kadowaki, Gustavo Aristides Santana Martinez e Alain RobinMaterials Research2009citado por 1 artigo

    The electrochemical behavior of three titanium dental implants purchased on the Brazilian market was evaluated in artificial saliva using open-circuit potential measurements, electrochemical impedance spectroscopy and potentiodynamic polarization. The three implants are passive in this medium but their corrosion…

  3. Chemical and topographic analysis of treated surfaces of five different commercial dental titanium implants

    Bruno Ramos Chrcanovic, Alexsander Ribeiro Pedrosa e Maximiliano Delany MartinsMaterials Research2012citado por 4 artigos

    We present a detailed investigation of the surface characteristics of five commercial titanium implants with different surface finishing (double acid etching, anodization and incorporation of Ca/P, acid etching and deposition of Ca/P, hydroxyapatite-blasting, acid etching and Ca/P-blasting) produced by five different…

  4. Wettability and adhesion of nanotubes applied to the surface of titanium implants by anodic oxidation

    Rogério de Lima ROMEIRO, Jorge Luiz ROSA, Lyncoln da Silva SIQUEIRA e mais 5Brazilian Oral Research2024

    Abstract The aim of this study was to evaluate the wettability and adhesion of self-organized TiO2 nanotubes formed on the surface of 8 commercially pure titanium (CP-Ti) disks and 12 dental implants (n = 12) by anodization in a glycerol-H2O (50-50 v/v) electrolyte containing NH4F. Two disk specimens were not…

  5. Surface analysis of titanium dental implants with different topographies

    M.H. Prado da Silva, G.A. Soares, C.N. Elias e mais 4Materials Research2000

    Cylindrical dental implants made of commercially pure titanium were analysed in four different surface finishes: as-machined, Al2O3 blasted with Al2O3 particles, plasma-sprayed with titanium beads and electrolytically coated with hydroxyapatite. Scanning electron microscopy (SEM) with Energy Dispersive X-ray Analysis…

  6. Osseointegration of Surface Coated and Surface Uncoated Titanium Dental Implants: A Systematic Review and Meta-Analysis

    Kiran Kumar Pandurangan, Anusha Kanniappan Sathiamurthy e Kaligotla Apoorva VasundharaPesquisa Brasileira em Odontopediatria e Clínica Integrada2026

    ABSTRACT Objective: To compare the osseointegration of surface-coated and uncoated titanium dental implants. Material and Methods: PubMed, Cochrane Library, SCOPUS, Web of Science, Google Scholar, and trial registries with no language or date of publication restrictions were searched on electronic databases. The risk…

  7. Compressive fatigue in titanium dental implants submitted to fluoride ions action

    Ana Lúcia Roselino Ribeiro, Jorge Roberto Noriega, Fábio Roberto Dametto e mais 1Journal of Applied Oral Science2007

    The aim of this study was to assess the influence of a fluoridated medium on the mechanical properties of an internal hexagon implant-abutment set, by means of compression, mechanical cycling and metallographic characterization by scanning electronic microscopy. Five years of regular use of oral hygiene with a sodium…

  8. Water Plasma Treatment Method: Simultaneous Sterilization and Surface Modification of Titanium-Based Implants

    Gustavo L. Likes, Rafael L. Novak, Vitor C.Y. Franceschini e mais 5Materials Research2025

    This study aims the applicability and efficacy of a new DC water plasma method at low temperature, for the sterilization of titanium contaminated samples and its effects on the surface oxide layer and morphological structure. The plasma treatment was carried out at a temperature of 60°C, for a predefined time of 10…

  9. Characterization of titanium surfaces for dental implants with inorganic contaminant

    Marilia Garcia Diniz, Marco Antonio Santos Pinheiro, Antonio Carlos Canabarro Andrade Junior e mais 1Brazilian Oral Research2005citado por 1 artigo

    The aim of this research was to characterize titanium surfaces blasted with aluminum oxide (Al2O3) particles using the KS 400 digital image processing program. Samples of grade II titanium plates were submitted to blasting processes using particles of Al2O3, and treated with a hydrofluoric acid-based solution. Three…

  10. Short-term immunosuppressive therapy does not affect the density of the pre-existing bone around titanium implants placed in rabbits

    Poliana Mendes Duarte, Getúlio Rocha Nogueira Filho, Enilson Antônio Sallum e mais 2Pesquisa Odontológica Brasileira2003citado por 1 artigo

    The aim of this study was to evaluate the influence of the administration and withdrawal of cyclosporin A/nifedipine on the bone density in a lateral area adjacent to implants placed in rabbits. Two screw-type titanium implants were placed bilaterally in twenty-eight New Zealand rabbits. The animals were assigned to…

  11. Paired evaluation of calvarial reconstruction with prototyped titanium implants with and without ceramic coating

    Davi Reis Calderoni, Rovilson Gilioli, André Luiz Jardini Munhoz e mais 6Acta Cirúrgica Brasileira2014

    PURPOSE:To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating.METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and…

  12. Comparative Study of Nanostructured TiO2 and SLA Surface Modifications for Titanium Implants: Surface Morphology and in vitro Evaluation

    Elisa Marchezini, Tatiane Cristine Silva de Almeida, Fernanda de Paula Oliveira e mais 6Materials Research2022

    Our work presents a comparative study of morphological characteristics and the osteogenic potential of MC3T3-E1 cells on different modified surfaces of titanium: nanostructured TiO2 with 20 and 100 nm nanotube diameter, and sandblasting and acid etching, commercially known as SLA. Nanostructured TiO2surface was…

  13. Porous Structure Characterization in Titanium Coating for Surgical Implants

    M.V. Oliveira, L.C. Pereira e C.A.A. CairoMaterials Research2002citado por 2 artigos

    Powder metallurgy techniques have been used to produce controlled porous structures, such as the porous coatings applied for dental and orthopedic surgical implants, which allow bony tissue ingrowth within the implant surface improving fixation. This work presents the processing and characterization of titanium porous…

  14. Comparative corrosion behavior of titanium alloys (ti-15mo and ti-6al-4v) for dental implants applications: A review

    Cátia S. D. Lopes, Mariana T. Donato e P. RamgiCorrosão e Protecção de Materiais2016

    Nowadays there is an increasing need of biocompatible materials due to the toxicity of the metals used. Focusing in dental implants, there are several problems concerning the corrosion of implants, for example, the high concentration of fluoride ions, which make an acid medium. Considering that titanium has excellent…

  15. The effects of severe plastic deformation on some properties relevant to Ti implants

    Anibal Andrade Mendes Filho, Vitor Luiz Sordi e Maurizio FerranteMaterials Research2012

    In some types of surgical implants, such as bone screws and plates, Grade 2 Ti is seriously considered as a replacement for the Ti-6Al-4V alloy. Advantages are lower cost and the absence of Al and V, which have been identified as potentially harmful to human health. The present paper shows that the lower strength of…

  16. An in vitro analysis of titanium aging surface optimization through variations in UV-C photofunctionalization and SLA: impact on titanium disk wettability

    Andreas TJANDRA, Ahmad KUSUMAATMAJA, Heni SUSILOWATI e mais 1Brazilian Dental Science2026

    ABSTRACT Objective This study aimed to evaluate the effects of UV-C duration and SLA surface treatment on the wettability of aged titanium disk surfaces. Material and Methods Twenty-four titanium disks (10 mm diameter, 1 mm thickness) underwent a 30-day aging and were divided into eight subgroups (n = 3) based on…

  17. PREPARATION AND CHARACTERIZATION OF Ti-Al-Nb ALLOYS FOR ORTHOPEDIC IMPLANTS

    V. Oliveira, R.R. Chaves, R. Bertazzoli e mais 1Brazilian Journal of Chemical Engineering1998citado por 1 artigo

    Pure titanium shows very interesting characteristics such as high strength-to-weight ratio, very good corrosion resistance and excellent biocompatibility, which make this material appropriate for use in orthopedic and dental implants. Due to the mechanical properties of pure titanium, its use in implants is restricted…

  18. The electrochemical properties of four dental casting suprastructure alloys coupled with titanium implants

    Suleyman Hakan Tuna, Nuran Ozcicek Pekmez, Filiz Keyf e mais 1Journal of Applied Oral Science2009citado por 1 artigo

    OBJECTIVES: As the choice of suprastructure alloy to be combined with titanium for the oral cavity is still a much debated issue, the aim of this study was to investigate the electrochemical interaction of the suprastructure/implant couples under the determined experiment conditions. MATERIAL AND METHODS: The…

  19. Modulation of osteoclastogenesis by macrogeometrically designed hydrophilic dual acid-etched titanium surfaces

    Rainde Naiara Rezende de JESUS, Christos TSATSANIS, Camilla Christian Gomes MOURA e mais 2Brazilian Oral Research2024

    Abstract The aim of this study was to evaluate the influence of implant macrodesign and surface hydrophilicity on osteoclast (OC) differentiation, activation, and survival in vitro. Titanium disks were produced with a sandblasted, dual acid-etched surface, with or without additional chemical modification for…