acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Surgical Fixation Devices”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Experimental model for the study of soft tissue fixation methods on skin-pericranium flaps in rats

    William César Cavazana, Roberto Kenji Nakamura Cuman, Wilton Mitsunari Takeshita e mais 1Acta Cirúrgica Brasileira2013citado por 1 artigo

    PURPOSE: To develop an experimental model to study and radiologically monitor displacement of skin flaps in the pericranium of rats subjected to traction and surgical fixation using suture anchored in a skull bone tunnel or with N-butyl-2-cyanoacrylate (HistoacrylTM) surgical adhesive. METHODS: Radiological markers…

  2. Dynamic compared to rigid fixation in lumbar spine: a systematic review

    Ricardo Vieira Botelho, Rafael Bastianello Junior, Luciana DiniGianini de Albuquerque e mais 1Revista da Associação Médica Brasileira2014

    Objective: The objective of this review is to reveal the quality of published data and the effect size of DPFs compared to rigid fixation in lumbar spine. Summary of background data: since 2002, several dynamic pedicle fixation (DPF) systems have been developed with the aim to stabilize the spine without the…

  3. Comparative Biomechanical Analysis of Two Olecranon Osteotomy Fixation Techniques

    Felipe Lacerda de Oliveira Pessôa, Marcio Liu Sandt, Marcos Alves Correia e mais 3Revista Brasileira de Ortopedia2025

    Abstract Objective To compare the biomechanical characteristics of olecranon osteotomy fixation using transcortical (TC) or intramedullary (IM) screws. Methods We sectioned synthetic polyurethane ulnas to simulate a Chevron osteotomy. Osteotomy fixations were performed using TC (n = 11) or IM screws (n = 11). After…

  4. Comparative Biomechanical Analysis of Two Olecranon Osteotomy Fixation Techniques

    Felipe Lacerda de Oliveira Pessôa, Marcio Liu Sandt, Marcos Alves Correia e mais 3Revista Brasileira de Ortopedia2025

    Abstract Objective To compare the biomechanical characteristics of olecranon osteotomy fixation using transcortical (TC) or intramedullary (IM) screws. Methods We sectioned synthetic polyurethane ulnas to simulate a Chevron osteotomy. Osteotomy fixations were performed using TC (n = 11) or IM screws (n = 11). After…

  5. Fixation of the Anterior Ligament Graft at the Tibial Pole: Biomechanical Analysis of Three Methods

    Fernando Pessoa Weiss, Felipe Augusto de Aguiar Possoli, Isabel Ziesemer Costa e mais 3Revista Brasileira de Ortopedia2019

    Abstract Objective Comparative biomechanical analysis of tibial fixation strength for ligament reconstruction with interference screw compared with screw post and washer, and compared with the associated fixation of both methods (hybrid fixation). Method A total of 54 specimens were used (porcine tibias and bovine…

  6. Mechanical evaluation of tibial fixation of the hamstring tendon in anterior cruciate ligament double-bundle reconstruction with and without interference screws

    Anderson de Aquino Santos, Mario Carneiro-Filho, Roberto Freire da Mota e Albuquerque e mais 3Clinics2020

    OBJECTIVE: The objective of this study was to compare two postero-lateral bundle (PLB) tibial fixation techniques for the reconstruction of the anterior cruciate ligament with double bundle: a technique without the use of an interference screw, preserving the native tibial insertion of the tendons of the gracilis and…

  7. A CAD/CAM Maxillary Guiding for Osteotomy, Drilling and Maxillary Positioning in Orthognathic Surgery: Accuracy Analysis.

    Douglas Voss Oliveira, David Normando, Diogo Souza Ferreira Rubim de Assis e mais 1Brazilian Archives of Biology and Technology2024

    Abstract Resin CAD/CAM guides for the maxilla are widely used and differ from custom miniplates essentially in that they do not have drill guides for screw fixation and use miniplates that must be modeled in surgery. To solve this problem, we have developed a new Maxillary guide bone-supported indicated for osteotomy…

  8. RADICULAR SYMPTOMS ASSOCIATED WITH EXTRAPEDICULAR SCREW PLACEMENT

    Jorge Alberto Pérez Terrazas, Daniel Sebastián Rivas Toledano, Arturo Rivera Galindo e mais 4Coluna/Columna2024

    ABSTRACT Objective: Transpedicular fixation has rapidly evolved over the last 100 years. A common complication is screw misplacement which can lead to neurological deficits, vascular damage, or organ perforation. We intend to assess the correlation between screw misplacement and radicular symptoms through the…

  9. Posterior Atlantoaxial Screw Placement in a Portuguese Population: A Morphometric Analysis Based on Computed Tomography Scan Measurements

    Rita Santos Martins, Catarina Silva Pereira, Carolina Lemos e mais 1Revista Brasileira de Ortopedia2023

    Abstract Objective The present study aims to evaluate the screw length and trajectory angles for posterior atlantoaxial fixation in a Portuguese population, through the study of cervical computed tomography (CT) scans. Methods Cervical CT scans of 50 adults were measured according to predefined screw trajectories of…

  10. CORRECTION OF THE SPINAL SAGITTAL PLANE: THE APPLICATION OF CONVERGENT OR DIVERGENT SCREWS

    ENGUER BERALDO GARCIA, LILIANE FARIA GARCIA, ENGUER BERALDO GARCIA JÚNIOR e mais 7Coluna/Columna2020citado por 1 artigo

    ABSTRACT Objective To present a new principle for correction of the sagittal plane of the spine through the convergent or divergent placement of monoaxial pedicle screws in this plane, associated with compression or distraction, to provide lordotizing or kyphotizing leverage force. Method A statistical mechanical…

  11. Radiographic evaluation of the use of transverse traction device in vertebral arthrodesis for degenerative diseases

    Edgar Takao Utino, João Paulo Machado Bergamaschi, Luciano Antonio Nassar Pellegrino e mais 4Coluna/Columna2014

    OBJECTIVE: Perform radiographic analysis of the use of Transverse Traction Device (DTT) with respect to fusion rate in patients submitted to vertebral arthrodesis for degenerative lumbar diseases. METHODS: We selected x-ray images on anteroposterior, lateral and oblique views and with maximum flexion and extension…

  12. May titanium spiral tacks contribute to intra-abdominal adhesion formation?

    Alberto Goldenberg, Carlos Eduardo Rivas e Gustavo SchvartsmanActa Cirúrgica Brasileira2012

    PURPOSE: To verify if titanium spiral tacks may contribute to intra-abdominal adhesion formation in rabbits. METHODS: Ten New Zealand white rabbits were used. Through videolaparoscopic surgery two titanium spiral tacks (ProTack®, Covidien®) were applied in the right flank. After 30 days the animals were submitted to…

  13. THE USE OF NITINOL RODS IN SURGICAL TREATMENT OF DEGENERATIVE SCOLIOSIS. 2.5-YEAR FOLLOW-UP

    Natalia Sergeyevna Morozova, Dmitriy Aleksandrovich Kolbovsky, Arkadiy Ivanovich Kazmin e mais 1Coluna/Columna2016

    ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases…