acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Self-ligating brackets”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Treatment of bimaxillary protrusion using intra- and extra-alveolar miniscrews associated to self-ligating brackets system

    Henrique Mascarenhas VillelaDental Press Journal of Orthodontics2020

    ABSTRACT Introduction: Moderate and severe bimaxillary protrusion impair the passive lip sealing and the facial and smile esthetics. The extraction of premolars can be avoided by the use of skeletal anchorage to retract both dental arches. This approach brings many advantages such as: prevents premolars extraction…

  2. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires

    Vanessa Vieira Leite, Murilo Baena Lopes, Alcides Gonini Júnior e mais 3Dental Press Journal of Orthodontics2014citado por 1 artigo

    OBJECTIVE: To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. MATERIAL AND METHODS : Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a ligating wire 0.10-in was used to ligate…

  3. Stability comparison of two different dentoalveolar expansion treatment protocols

    Ezgi Atik e Tülin TanerDental Press Journal of Orthodontics2017

    ABSTRACT Objective: The aim of this study was to compare the longitudinal stability of the conventional straight-wire system after the use of a quad-helix appliance with Damon self-ligating system in patients with Class I malocclusion. Methods: 27 adolescent patients were evaluated at three different periods…

  4. Comparison of changes in the dental transverse and sagittal planes between patients treated with self-ligating and with conventional brackets

    Javier Moyano, Diana Montagut, Ramon Perera e mais 2Dental Press Journal of Orthodontics2020

    ABSTRACT Introduction: Several advantages have been established regarding the efficiency of self-ligating brackets (SL). In spite of some controversy surrounding this question in the literature, clinical results confirm that “arch development” requires fewer extractions. Objective: The objective of this study was to…

  5. Opening and closure forces of sliding mechanisms of different self-ligating brackets

    Paola GANDINI, Linda ORSI, Maria Francesca SFONDRINI e mais 1Journal of Applied Oral Science2013citado por 1 artigo

    Self-ligating brackets engage the wire by means of a slide mechanism. Forces that have to be applied to open and close the sliding mechanism of brackets are still unknown. Objective The aim of this study was to measure and compare the opening and closure forces of different self-ligating brackets. Material and Methods…

  6. Air-powder polishing on self-ligating brackets after clinical use: effects on debris levels

    Mônica L. S. Castro Aragón, Leandro Santiago Lima e David NormandoDental Press Journal of Orthodontics2016

    ABSTRACT Introduction: Debris buildup on brackets and arch surfaces is one of the main factors that can influence the intensity of friction between bracket and orthodontic wire. Objective: This study sought to evaluate the effect of air-powder polishing cleaning on debris levels of self-ligating ceramic brackets at…

  7. Photoelastic analysis of stress generated by wires when conventional and self-ligating brackets are used: A pilot study

    Guilherme Caiado Sobral, Mário Vedovello Filho, Viviane Veroni Degan e mais 1Dental Press Journal of Orthodontics2014citado por 1 artigo

    OBJECTIVE: By means of a photoelastic model, this study analyzed the stress caused on conventional and self-ligating brackets with expanded arch wires. METHOD: Standard brackets were adhered to artificial teeth and a photoelastic model was prepared using the Interlandi 19/12 diagram as base. Successive activations…

  8. Assessment of surface friction of self-ligating brackets under conditions of angulated traction

    Roberta Buzzoni, Carlos N. Elias, Daniel J. Fernandes e mais 1Dental Press Journal of Orthodontics2012citado por 1 artigo

    OBJECTIVE: The aim of this study was to assess resistance to sliding of stainless steel passive self-ligating brackets with 0° and 2.5° angulations and to compare them to active self-ligating brackets at zero angulation. The hypothesis to be tested was that passive self-ligating brackets produce lower frictional…

  9. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Rodrigo Hitoshi Higa, Nayara Thiago Semenara, José Fernando Castanha Henriques e mais 3Dental Press Journal of Orthodontics2016

    ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and…

  10. Evaluation of friction in metal, ceramic and self-ligating brackets submitted to sliding mechanics

    Aryadne Cipreste MASCARELO, Ana Paula GODOI, Vivian FURLETTI e mais 2Revista de Odontologia da UNESP2018

    Abstract Objective With the purpose of evaluating the best results for a proposed orthodontic treatment, the aim of this research was to verify the frictional force between archwires and orthodontic brackets in sliding mechanics. Material and method Three different types of brackets were used: conventional metal…

  11. Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions

    Sérgio Ricardo Jakob, Davison Matheus, Maria Cristina Jimenez-Pellegrin e mais 2Dental Press Journal of Orthodontics2014citado por 1 artigo

    OBJECTIVE: The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC), self-ligating ceramic (In-Ovation, Denstply GAC) and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC). METHODS: Five brackets were used for each model…

  12. Does self-ligating brackets type influence the hysteresis, activation and deactivation forces of superelastic NiTi archwires?

    José Rino Neto, Gilberto Vilanova Queiroz, João Batista de Paiva e mais 1Dental Press Journal of Orthodontics2013citado por 2 artigos

    OBJECTIVE: To compare hysteresis, activation and deactivation forces produced by first-order deformation of Contour 0.014-in NiTi wire (Aditek, Brazil) in four brands of self-ligating brackets: Damon MX, Easy Clip, Smart Clip and In-Ovation. METHODS: Activation and deactivation forces were measured in an Instron…

  13. Streptococcus mutans adherence to conventional and self-ligating brackets: an in vitro study

    Murilo Fernando Neuppmann FERES, Fernanda VICIONI-MARQUES, Fábio Lourenço ROMANO e mais 4Dental Press Journal of Orthodontics2021

    ABSTRACT Introduction: Although self-ligating brackets presumably provide better hygiene conditions, no consensus has been reached so far. Objective: Therefore, the objective of this study was to evaluate, in an in vitro experimental design, the adherence of Streptococcus mutans (SM) in self-ligating and conventional…

  14. Are self-ligating brackets related to less formation of Streptococcus mutans colonies? A systematic review

    Leonard Euler Andrade Gomes do Nascimento, Margareth Maria Gomes de Souza, Angela Rita Pontes Azevedo e mais 1Dental Press Journal of Orthodontics2014citado por 2 artigos

    OBJECTIVE: To verify, by means of a systematic review, whether the design of brackets (conventional or self-ligating) influences adhesion and formation of Streptococcus mutans colonies. METHODS: Search strategy: four databases (Cochrane Central Register of Controlled Trials, Ovid ALL EMB Reviews, PubMed and BIREME)…

  15. Pain Perception and Rate of Canine Retraction Through Self-Ligating Brackets and Conventional Elastomeric Ligation System: A Split Mouth Study

    Irfan Qamruddin, Asma Gul Khan, Fatima Muhmmad Asif e mais 4Pesquisa Brasileira em Odontopediatria e Clínica Integrada2020

    Abstract Objective: To evaluate the rate of tooth movement and the pain perception via self-ligating (SL) and conventional elastomeric ligation brackets (CB) system. Material and Methods: This study has been conducted at the Orthodontic Department of Baqai Dental College, Baqai Medical University. The sample size of…

  16. Surgery-first approach with 3D customized passive self-ligating brackets and 3D surgical planning: Case report

    Juan Fernando Aristizábal, Rosana Martínez-Smit, Cristian Díaz e mais 1Dental Press Journal of Orthodontics2018

    ABSTRACT It is possible to unify three-dimensional customized orthodontic techniques and three-dimensional surgical technology. In this case report, it is introduced a treatment scheme consisting of passive self-ligation customized brackets and virtual surgical planning combined with the orthognathic surgery-first…

  17. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    Manoela Fávaro Francisconi, Guilherme Janson, José Fernando Castanha Henriques e mais 1Journal of Applied Oral Science2016citado por 3 artigos

    ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual…

  18. Torque expression in conventional and self-ligating orthodontic brackets: An in vitro study

    Martha de Abreu Avila, José Guilherme Neves, Américo Bortolazzo Correr e mais 4Brazilian Dental Journal2026

    Abstract This study assessed torque expression at different angulations of conventional, interactive, and passive self-ligating brackets, with or without metal ligatures, and evaluated surface morphology and chemical composition (%). All brackets (Roth prescription, 0.022" x 0.028" slot) were fixed to round acrylic…

  19. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    Rogerio Amaral Tupinambá, Cristiane Aparecida de Assis Claro, Cristiane Aparecida Pereira e mais 2Dental Press Journal of Orthodontics2017citado por 1 artigo

    ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic…

  20. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Maria Regina Guerra MONTEIRO, Licinio Esmeraldo da SILVA, Carlos Nelson ELIAS e mais 1Journal of Applied Oral Science2014citado por 1 artigo

    Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini…