acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Robert Montés-Micó”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

    Teresa Ferrer-Blasco, José J. Esteve-Taboada, Alberto Domínguez-Vicent e mais 4Arquivos Brasileiros de Oftalmologia2019

    ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by…

  2. Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

    Daniel Monsálvez-Romín, Alberto Domínguez-Vicent, José. J. Esteve-Taboada e mais 2Arquivos Brasileiros de Oftalmologia2019

    ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean…

  3. Assessing the accommodation response after near visual tasks using different handheld electronic devices

    Aikaterini I. Moulakaki, Alberto Recchioni, Antonio J. Del Águila-Carrasco e mais 2Arquivos Brasileiros de Oftalmologia2017

    ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than…

  4. In vivo OCT assessment of anterior segment central axial lengths with accommodation

    Daniel Monsálvez-Romín, Aikaterini I. Moulakaki, José J. Esteve-Taboada e mais 2Arquivos Brasileiros de Oftalmologia2017

    ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central…

  5. Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction

    Santiago García-Lázaro, Teresa Ferrer-Blasco, Hema Radhakrishnan e mais 2Arquivos Brasileiros de Oftalmologia2014

    Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an…

  6. Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator

    Cari Pérez-Vives, César Albarrán-Diego, Santiago García-Lázaro e mais 2Arquivos Brasileiros de Oftalmologia2014

    Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical…

  7. Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices

    Alberto Domínguez-Vicent, Daniel Monsálvez-Romín, Antonio Jesus Del Águila-Carrasco e mais 2Arquivos Brasileiros de Oftalmologia2014

    Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged…

  8. Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

    Alberto Domínguez-Vicent, Daniel Monsálvez-Romín, César Albarrán-Diego e mais 2Arquivos Brasileiros de Oftalmologia2014

    Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG…

  9. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Teresa Ferrer-Blasco, Santiago García-Lázaro, César Albarrán-Diego e mais 2Arquivos Brasileiros de Oftalmologia2013citado por 1 artigo

    PURPOSE: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model) intraocular lens (IOL). METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral…

  10. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Teresa Ferrer-Blasco, Santiago García-Lázaro, César Albarrán-Diego e mais 2Arquivos Brasileiros de Oftalmologia2012citado por 1 artigo

    PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were…