acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Retinal perforations”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Comparisons of retinal nerve fiber layer thickness changes after macular hole surgery

    Nelson Chamma Capelanes, André Vasconcellos Diniz, Érika Pacheco Magalhães e mais 1Arquivos Brasileiros de Oftalmologia2018citado por 1 artigo

    ABSTRACT Purpose: To compare postoperative changes in retinal nerve fiber layer thickness in patients with macular holes treated with vitrectomy with Brilliant Blue-assisted internal limiting membrane peeling. Methods: Twenty-two eyes of 20 patients with macular holes were studied. Each eye was selected to undergo…

  2. Evaluating peripheral retina: a cautionary note on miotics

    Rogil José de Almeida Torres, Andréa Luchini, Rogério João de Almeida Torres e mais 4Revista Brasileira de Oftalmologia2026

    ABSTRACT Objective: To underscore the critical importance of assessing the peripheral retina in all patients, especially those planning to use miotics. Methods: A retrospective and observational study was conducted at a single ophthalmological medical center, using records from the International Classification of…

  3. Ultrasonography-guided scleral buckle retinopexy and cryotherapy: case report

    Daniel da Rocha Lucena, Jefferson Augusto Santana Ribeiro, Marco Sérgio Pinto Alves Folgosa e mais 2Arquivos Brasileiros de Oftalmologia2009citado por 1 artigo

    If the ocular media are clear, indirect binocular ophthalmoscopy allows retinal detachment and retinal tear identification and treatment under direct visualization. However, if opacities are present preventing direct fundus examination, ultrasonography becomes the most important tool for evaluating the posterior…

  4. Estimating the volume of the vitrectomized space using axial length: a guideline

    Rodrigo Pessoa Cavalcanti Lira, Andrea Andrade Azevedo de Vasconcelos, Valesca Castro Neri e mais 4Arquivos Brasileiros de Oftalmologia2025citado por 1 artigo

    ABSTRACT Purpose: The volume of the vitreous chamber varies with the size of the eye. The space created in the vitreous cavity by a vitrectomy is called the vitrectomized space. The volume of the vitrectomized space is strongly correlated with the axial length of the eye. This study aims to present guidelines for…

  5. Influence of the dilution method on the intraocular duration of C3F8 in vitrectomy for macular hole: a randomized clinical trial

    Alexandre Paashaus da Costa Pinto, Daniel Tenório Camelo Soares, Marília Rocha Costa e mais 1Arquivos Brasileiros de Oftalmologia2024citado por 1 artigo

    ABSTRACT Purpose: To compare the injection of small amounts of undiluted C3F8 with the traditional gas injection in vitrectomy for macular hole treatment. Methods: This clinical trial included 26 individuals divided into two groups. Group 1 received an intravitreal injection of 0.9-1.0 mL of 100% C3F8, and Group 2…

  6. 360-degree pedicled inverted internal limiting membrane flap technique without face-down posturing for large idiopathic macular holes: a retrospective case series

    Alana Viana Alencar de Oliveira, Jefferson Souza Pinto Porto, Levy Paz Aguiar e mais 1Arquivos Brasileiros de Oftalmologia2024

    ABSTRACT Purpose: This study aimed to determine closure rates of large idiopathic macular holes treated with pars plana vitrectomy and 360-degree pedicled inverted internal limiting membrane flap without face-down posturing and define visual improvement, types of macular hole closure, and external retina integrity as…

  7. Autologous platelet concentrate for the treatment of macular hole: a systematic review and meta-analysis

    Dillan Cunha Amaral, Mário Luiz Ribeiro Monteiro, Milton Ruiz Alves e mais 6einstein (São Paulo)2024

    ABSTRACT Autologous platelet concentrates are rich in growth factors and have shown potential for high anatomical success rates in macular hole treatment. However, no systematic review has yet assessed its impact. Therefore, this study aimed to conduct a comprehensive review and meta-analysis on the comparative…

  8. Surgical results regarding the correction of macular hole with and without face-down posturing using 25% SF6 gas: a retrospective case series

    Andre Luis Carvalho de Moura Bastos, Marcos Pereira de Ávila, David Leonardo Cruvinel Isaac e mais 2Arquivos Brasileiros de Oftalmologia2020citado por 1 artigo

    ABSTRACT Purpose: This study aims to compare the anatomical success rates of vitrectomy and SF6 gas tamponade for macular hole surgery with and without postoperative face-down posturing. Methods: This was an observational, longitudinal, and retrospective case series analysis. The study included 52 eyes from 52…

  9. Effect of macular hole volume on postoperative central macular thickness

    Taylan Ozturk, Eyyup Karahan, Duygu Er e mais 3Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Purpose: To evaluate the association between macular hole volume (MHV) and postoperative central macular thickness (CMT) using spectral-domain optical coherence tomography (SD-OCT). Methods: Thirty-three eyes of 30 patients with a large full-thickness idiopathic macular hole with or without vitreomacular…

  10. Nonarteritic anterior ischemic optic neuropathy following pars plana vitrectomy for macular hole treatment: case report

    Leonardo Provetti Cunha, Luciana Virgínia Ferreira Costa Cunha, Carolina Ferreira Costa e mais 1Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Herein, we report a case of nonarteritic anterior ischemic optic neuropathy (NAION) following uneventful pars plana vitrectomy for macular hole treatment. A 56-year-old previously healthy woman presented with a full-thickness macular hole in right eye (OD) and small cup-to-disc ratios in both eyes. Five days…

  11. Spontaneous closure of pediatric traumatic macular hole: case report and spectral-domain OCT follow-up

    Juliana de Filippi Sartori, Francisco Stefanini e Nilva Simeren Bueno de MoraesArquivos Brasileiros de Oftalmologia2012

    Spontaneous closure of a traumatic macular hole (TMH) is an unusual outcome. Optical coherence tomography (OCT) and clinical follow-up enabled monitoring of this resolution during a period of a few weeks. We describe a case of spontaneous closure of a TMH with complete visual recovery in a 15 year-old boy and show the…

  12. Macular hole: 10 and 20-MHz ultrasound and spectral-domain optical coherence tomography

    Juliana Mantovani Bottós, Virginia Laura Lucas Torres, Liliane Andrade Almeida Kanecadan e mais 4Arquivos Brasileiros de Oftalmologia2012citado por 1 artigo

    PURPOSE: Optical coherence tomography (OCT) is valuable for macula evaluation. However, as this technique relies on light energy it cannot be performed in the presence of opaque media. In such cases, the ultrasound (US) may predict some macular features. The aim of this study was to characterize images obtained by…