  1. Effect of temperature on the activity of efflux pumps in selected species of human opportunistic bacterial pathogens

    Dusan Hurton, Lukás Hleba, Jana Petrová e mais 3Memórias do Instituto Oswaldo Cruz2025

    BACKGROUND Efflux pumps represents one of the most important mechanisms of antibiotic resistance. They allow bacteria to expel antibiotics from their cells before they reach the target site. OBJECTIVES The main objective of this work was to examine how cultivation temperature and its variations affect the activity of…

  2. Start-up delay in syringe infusion pumps with different rates and priming techniques of intravenoust sets

    Natalie Marino Vieira, Maria Paula de Oliveira Pires, Gabriela Beltran Crespo e mais 3Revista Gaúcha de Enfermagem2022

    ABSTRACT Objective: To investigate infusion pumps start-up delay according to different brands of infusion pumps, flow rates and intravenous sets priming techniques. Method: The experimental study simulated clinical practice under controlled conditions, using a 50 mL syringe with NaCl 0.9% solution, two syringe…

  3. Usability of volumetric infusion pumps in pediatric intensive care

    Elizandra Cassia da Silva Oliveira, Roberto Carlos Lyra da Silva, Gustavo Aires de Arruda e mais 1Revista da Escola de Enfermagem da USP2021

    ABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to…

  4. Implementing barcode medication administration and smart infusion pumps is just the beginning of the safety journey to prevent administration errors

    Christina Michalek e Stacy L CarsonFarmacia Hospitalaria2020citado por 1 artigo

    Abstract Introduction: Healthcare-related technology has been widely accepted as a key patient safety solution to reduce adverse drug events by decreasing the risk of human error. The introduction of technology can enhance safety and support workflow; however, it does not eliminate all error types and may create new…

  5. Is the efflux pump inhibitor Verapamil a potential booster for isoniazid against Mycobacterium tuberculosis?

    Renata Claro Ribeiro do Amaral, Katiany Rizzieri Caleffi-Ferracioli, Fernanda de Oliveira Demitto e mais 6Brazilian Journal of Pharmaceutical Sciences2020

    The membrane-based efflux pump systems are recognized to have an important role in pathogenicity and drug resistance in Mycobacterium tuberculosis by the extrusion of toxic substrates and drugs from the inner bacillus. This study aimed to investigate the in vitro interaction of Verapamil (VP), an efflux pump…

  6. Hemolysis risk after packed red blood cells transfusion with infusion pumps

    Ana Maria Miranda Martins Wilson, Maria Angélica Sorgini Peterlini e Mavilde da Luz Gonçalves PedreiraRevista Latino-Americana de Enfermagem2018citado por 2 artigos

    ABSTRACT Objective: To evaluate the hemolysis biomarkers of packed red blood cells transfused by two different linear peristaltic infusion pumps at two infusion rates. Method: An experimental and randomized study was designed simulating the clinical practice of transfusion. Two linear peristaltic infusion pumps from…

  7. New formula proposal for the determination of variable speed pumps efficiency

    José Nilton de Abreu Costa, Marco Aurélio Holanda de Castro, Luís Henrique Magalhães Costa e mais 1RBRH2018

    ABSTRACT The use of pumps which work with variable rotation speed consists of an appropriate tactics for reduction of energy costs in the pump systems. In case of change in speed, the pump starts to work in a new flow pattern, head and efficiency values. Two empirical formulas can be found in the literature in order…

  8. Dimensionless curves of centrifugal pumps for water supply systems: development and case study

    Jóice Cristini Kuritza, Giovani Camponogara, Marcelo Giulian Marques e mais 2RBRH2017

    ABSTRACT Centrifugal pumps are widely used in water supply systems and account for more than 90% of the electricity consumption of water pumping stations. Studies that seek to generalize the characterization of performance curves of centrifugal pumps are extremely useful. A study was carried out on the dimensionless…

  9. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Ana Maria Miranda Martins Wilson, Maria Angélica Sorgini Peterlini e Mavilde da Luz Gonçalves PedreiraRevista Latino-Americana de Enfermagem2016citado por 1 artigo

    ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific…

  10. Clinical evaluation of the Spiral Pump® after improvements to the original project in patients submitted to cardiac surgeries with cardiopulmonary bypass

    Jarbas Jakson Dinkhuysen, Aron Jose Pazin de Andrade, Juliana Leme e mais 4Brazilian Journal of Cardiovascular Surgery2014citado por 1 artigo

    Objective: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. Methods: This…

  11. Identification of Exiguobacterium artemiae Strains Tolerant to Xenobiotics in Wastewater from the Bogota River, Colombia

    Camilo Torres-Trujillo, Nelson Enrique Arenas, Magdalena Wiesner e mais 7Brazilian Archives of Biology and Technology2026

    Abstract The Bogotá River receives a large amount of domestic and industrial wastewater, which has significant ecological impacts. Although these effluents charge several bacteria that represent a risk to human, animal, and vegetable health, some species can also resist high concentrations of contaminants. This study…

  12. Multiple basal infusion rates in open-loop insulin delivery systems: is there a metabolic benefit?

    Juliana Marques Sá, Sara de Campos Lopes, Maria Joana Santos e mais 2Archives of Endocrinology and Metabolism2024

    ABSTRACT Objective: To evaluate glycemic control according to the number of daily basal rates (BRs) in type 1 diabetes patients using continuous subcutaneous insulin infusion (CSII). Subjects and methods: Cross-sectional study of patients treated with an open-loop CSII for at least 6 months and using a flash glucose…

  13. Risk management and safety in the use of patient-controlled analgesia pumps: a scoping review

    Thamires Ribeiro da Silva, Erica Brandão de Moraes, Juliana Gomes Poubel e mais 2BrJP2023

    ABSTRACT BACKGROUND AND OBJECTIVES: Patient-controlled analgesia (PCA) is effective in controlling pain, but has numerous associated risks, such as: hypotension, respiratory depression, seizures and excessive sedation. The promotion of patient safety aims to reduce the risk of unnecessary health injuries and…

  14. Proton pumps inhibitors in gastroesophageal reflux disease: what is the best regimen? An evidence-based review.

    Rui Silva e Nuno Teles PintoRevista Portuguesa de Medicina Geral e Familiar2021

    Abstract Objectives: Gastroesophageal reflux disease is one of the most common gastrointestinal diagnoses. This disorder causes many symptoms and may induce the development of Barret’s esophagus and esophageal adenocarcinoma. Proton pump inhibitors are the most used treatment and, usually, are prescribed for…

  15. Air entrainment and pressure drop in low-cost ejectors

    DANIEL D. LIMA e IRAN E. LIMA NETOAnais da Academia Brasileira de Ciências2020

    Abstract This study investigated experimentally the air entrainment and pressure drop in low-cost ejectors composed of two pieces shaped from PVC bars inserted in a 25 mm T-junction of the same material. The hydraulic behavior was very similar for the different ejector designs, and linear relationships between the…

  16. Tetracycline resistance mediated by tet efflux pumps in clinical isolates of Acinetobacter baumannii

    Maryam Beheshti, Abdollah Ardebili, Fatemeh Beheshti e mais 6Revista do Instituto de Medicina Tropical de São Paulo2020

    ABSTRACT Acinetobacter baumannii is one of the most frequent nosocomial pathogen capable of acquiring resistance to different antimicrobials. The aim of this study was to investigate the activity of tetracycline, doxycycline and minocycline, the prevalence of tet(A) and tet(B) determinants, and the role of efflux pump…

  17. Handling errors in conventional and smart pump infusions: A systematic review with meta-analysis

    Ana Paula Amorim Moreira, Márglory Fraga de Carvalho, Roberto Carlos Lyra da Silva e mais 3Revista da Escola de Enfermagem da USP2020

    Abstract Objective: To identify the scientific evidence on the frequency of handling errors of conventional and smart pump infusions in intravenous insulin therapy in intensive care units. Method: A systematic review with meta-analysis conducted in the Virtual Health Library, MEDLINE via PubMed, Scopus and Web of…

  18. Optimal pump selection for variable speed operation in water distribution network

    Débora Salomé Móller, Gustavo Meirelles Lima, Bruno Melo Brentan e mais 1RBRH2020citado por 1 artigo

    ABSTRACT The optimization of pumping stations operation in water distribution networks has been largely studied, especially with the development of speed drivers, which allowed the machines to adjust the hydraulic power inserted to the system according to the demand requirements. Although this approach results in high…

  19. Cost-effectiveness of infusion pumps to reduce errors in a Pediatric ICU

    Roberto Carlos Lyra da Silva, Thiago QuinellatoLouro, Antônio Augusto de Freitas Peregrino e mais 3Revista Brasileira de Enfermagem2019

    ABSTRACT Objective: To analyze cost-effectiveness and to calculate incremental cost-effectiveness ratio of the use of infusion pumps with drug library to reduce errors in intravenous drug administration in pediatric and neonatal patients in Intensive Care Units. Methods: Mathematical modeling for economic analysis of…