acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Prosthesis design”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform

    José Ricardo Pécora e Valéria RomeroRevista Brasileira de Ortopedia2021citado por 1 artigo

    Abstract Objective To evaluate the wear of polyethylene in a Brazilian ultracongruent knee prosthesis with a rotating platform (Rotaflex, Víncula, Rio Claro, SP, Brasil). Methods We used the test method with the loading and preparation parameters mentioned in the standards regulation ISO 14243-1:2009, and the…

  2. Screwed and cement implant prosthesis: current clinical considerations

    Bruna Palmeira COSTA, Julliana Cariry Palhano FREIRE, Waleska Ohana de Souza MELO e mais 3RGO - Revista Gaúcha de Odontologia2021

    ABSTRACT Introduction: There is no consensus as to which cemented or screwed retention system is best to avoid bone loss around the implant from a fixed implant-supported restoration. Objective: To evaluate the prosthesis retention systems on screw and cemented implants, regarding: bone loss, survival and failure…

  3. Mobile-Bearing versus Fixed-Bearing Total Knee Arthroplasty: A Comparative Analysis of Long-Term Clinical and Implant Survival Outcomes

    Pablo Agustín Ramos Guarderas, Pablo David Ramos Murillo, Carlos Patricio Peñaherrera Carrillo e mais 3Revista Brasileira de Ortopedia2025

    Abstract Objective The present study compared clinical outcomes, implant survival, and axial mobility between mobile-bearing (MB) and fixed-bearing (FB) prostheses in patients with medial knee osteoarthritis. Methods A retrospective cohort study of 1,289 patients who underwent primary cemented total knee arthroplasty…

  4. A Retrospective Cohort Study of the Effects of Canal Filling Ratio and Femoral Bone Density Change on the Outcomes of Anatomical and Double-tapered Wedge Stems

    Thakrit Chompoosang e Patcharavit PloynumponRevista Brasileira de Ortopedia2024

    Abstract Objective This study aims to compare the proximal femoral bone density changes in follow-up X-ray imaging and the proximal filling ratios of stems between anatomical and double-tapered wedge stem designs. Methods Patients aged between 18 and 80 years who received primary total hip arthroplasty using both…

  5. Effect of clinical and laboratory techniques of cementation on the assessment of marginal and internal fit of prosthetic elements

    Carolina Chaves Pinto, Leonardo André Lins da Silva, Cristiana Almeida de Assis Licurci e mais 1Brazilian Journal of Oral Sciences2024

    Aim The aim of this in vitro study was to compare machine and manual cementation of prosthetic elements by measuring internal and marginal fits. Methods Eighteen anatomic prefabricated abutments were used to manufacture zirconia copings in the Ceramill (n=9) and Lava systems (n=9). The copings were cemented with a…

  6. Total removal of the buccal flange in maxillary prosthetic preparation: a necessity?: case report

    Stephanie Gomes Assunção Alves, Lorena Gonçalves Alexandrino, Gustavo Eduardo Casagrande e mais 2RGO - Revista Gaúcha de Odontologia2024

    ABSTRACT Fixed implant-supported complete maxillary dentures aim to rehabilitate aesthetic, phonetic, and functional aspects of edentulous arches. A previous prosthetic preparation without a flange in the anterior sector makes it possible to evaluate the labial support and the existing space for the future prosthesis…

  7. Correlation Between Implant Positioning and Functional Outcomes in Partial Shoulder Resurfacing

    Gilberto Daniel Luz, Amanda S. Cavalcanti, Júlio Ferreira e mais 3Revista Brasileira de Ortopedia2022citado por 1 artigo

    Abstract Objective The present study aimed to correlate functional outcomes and implant positioning in a case series of partial shoulder resurfacing arthroplasties. Methods A total of 25 patients were assessed for range of motion, functional outcome per the University of California at Los Angeles (UCLA) score and…

  8. Is The Size of the Currently Available Implants for Total Hip Arthroplasty Adequate for Our Population?

    Thiago Sampaio Busato, Gabriella Maira Rodrigues Barbosa, Anderson Emanuel Kumandala Velho e mais 3Revista Brasileira de Ortopedia2019

    Abstract Objective To determine if the dimensions of selected national and imported implants used in total hip arthroplasty surgeries are adequate regarding the anthropometric profile of the Brazilian population. Methods A retrospective study of patients submitted to primary total hip arthroplasty. Patients with…

  9. Patient-specific instrumentation in total knee arthroplasty. Should we adopt it?

    Ana Sofia Teles Rodrigues e Manuel António Pereira GutierresRevista Brasileira de Ortopedia2017

    ABSTRACT Total knee arthroplasty (TKA) is a surgical procedure of paramount relevance that restores a substantial degree of function in arthritic knees. Increased consideration has been given to the influence of limb alignment on longevity after TKA, as errors in component placement can be associated with inferior…

  10. Femoral Stem Subsidence in Total Hip Arthroplasty: Comparison between Fixation Principles

    André N. B. M. de Macedo, Lourenço P. Peixoto, João A. M. Guimarães e mais 1Revista Brasileira de Ortopedia2026

    Abstract Objective To compare the magnitude of subsidence between single- (SW) and double-wedge (DW) femoral stems in primary total hip arthroplasties (THAs), and to identify factors associated with clinically relevant subsidence. Methods Retrospective cohort study with 82 patients (164 hips) undergoing bilateral THA…

  11. Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis

    Álvaro Machado Rösler, Fernando Antonio Lucchese, Pablo Maria Alberto Pomerantzeff e mais 1Brazilian Journal of Cardiovascular Surgery2023citado por 1 artigo

    ABSTRACT Objective: To assess actual data on the safety, effectiveness, and hemodynamic performance of Bovine Pericardium Organic Valvular Bioprosthesis (BVP). Methods: The BIOPRO Trial is an observational, retrospective, non-comparative, non-randomized, and multicenter study. We collected data from 903 patients with…

  12. Traumatic dissociation of the tibial insert with patellar tendon rupture after high-flex posterior-stabilized Genesis II total knee arthroplasty

    Sanjay Agarwala e Mayank VijayvargiyaRevista Brasileira de Ortopedia2018

    ABSTRACT The authors report the first case of traumatic late dissociation of the polyethylene insert with patellar tendon rupture after total knee arthroplasty using a high-flex posterior-stabilized Genesis II prosthesis in a 60-year-old Parkinson's disease patient. Insert dislodgement has been described most commonly…

  13. Connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy

    Piero Rocha Zanardi, Bruno Costa, Roberto Chaib Stegun e mais 3Brazilian Dental Journal2012citado por 2 artigos

    The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments…

  14. Failure of prosthetic screws on 971 implants

    Carolina Schäffer Morsch, Caroline Freitas Rafael, Juan Felipe Montero Dumes e mais 3Brazilian Journal of Oral Sciences2015

    Abstract Aim: To evaluate the presence of failures in prosthetic screws and whether these failures are related to the type of prosthesis, abutment angulation and presence or not of intermediate. Methods: Two-hundred and sixty-seven patients were evaluated at the Federal University of Santa Catarina, totaling 971…

  15. Effect of veneering material on the deformation suffered by implant-supported fixed prosthesis framework

    Antônio Francisco GRANDO, Carlos Eduardo Edwards REZENDE, Edson Antônio Capello SOUSA e mais 1Journal of Applied Oral Science2014

    Knowing how stresses are dissipated on the fixed implant-supported complex allows adequate treatment planning and better choice of the materials used for prosthesis fabrication. Objectives: The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast…

  16. Success and survival rates of mandibular overdentures supported by two or four implants: a systematic review

    Isabelle de Sousa Dantas, Mariana Barbosa Câmara de Souza, Maria Helena de Siqueira Torres Morais e mais 2Brazilian Oral Research2014citado por 3 artigos

    This systematic review evaluated the influence played by the number of implants on the results of rehabilitation treatment with mandibular overdentures on 2 or 4 implants. The literature search was conducted using PubMed, Embase and Cochrane databases. Specific terms were used in performing a search from January 1980…

  17. Combined transscleral fixation of an artificial iris prosthesis with an intraocular lens

    Uzeyır Gunenc, Taylan Ozturk, Gul Arikan e mais 1Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a…

  18. Range of motion predictability after total knee arthroplasty with medial pivot prosthesis

    Lúcio Honório de Carvalho Júnior, Bruno Presses Teixeira, Cláudio Otávio da Silva Bernardes e mais 3Revista Brasileira de Ortopedia2017

    ABSTRACT OBJECTIVE: To assess whether there the final range of motion (ROM) results achieved by patients undergoing total knee arthroplasty (TKA) with prosthesis using Medial Pivot design are predictable. METHODS: Between January and August of 2014, 155 patients with primary osteoarthritis of knee who underwent TKA…

  19. Developing solutions for complex oral rehabilitation: the potential of subtractive manufacturing

    Tatiana Cursino PEREIRA, Ana Paula de ALMEIDA GOMES, Bruna Oliveira CAMPOS e mais 4Brazilian Dental Science2026

    ABSTRACT Background The use of digital technologies expands the possibilities for manufacturing complete dentures, allowing for greater standardization of procedures and a reduction in laboratory steps. Among these approaches, subtractive manufacturing enables the fabrication of dentures from pre-polymerized discs…

  20. Clinical outcomes of quad-loop intraocular lenses: trifocal, bifocal and toric types

    Camila Mendes Costa Campelo, Fabricio Afonso Borges Silva, Paula Marques Marinho e mais 5Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: The purpose of this study was to assess visual outcomes and patient satisfaction following cataract surgery involving the implantation of quad-loop intraocular lenses, including trifocal, bifocal, and toric variants. Methods: Information was obtained from both physical and electronic medical records…