acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Presbyopia”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction

    Santiago García-Lázaro, Teresa Ferrer-Blasco, Hema Radhakrishnan e mais 2Arquivos Brasileiros de Oftalmologia2014

    Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an…

  2. Visual magnification through a smartphone application designed to assist presbyopia

    Allan Victor Gonçalves, Daniel Montenegro, Edgar Marçal e mais 1Revista Brasileira de Oftalmologia2026

    ABSTRACT Objective: To develop and validate a smartphone application capable of magnifying near images and, through educational videos, informing users about presbyopia. Methods: This was a cross-sectional, quantitative study conducted by a multidisciplinary team of ophthalmologists and software engineers. The…

  3. Short-term visual performance of soft multifocal contact lenses for presbyopia

    Jennifer Sha, Ravi C. Bakaraju, Daniel Tilia e mais 6Arquivos Brasileiros de Oftalmologia2016citado por 1 artigo

    ABSTRACT Purpose: To compare visual acuity (VA), contrast sensitivity, stereopsis, and subjective visual performance of Acuvue® Oasys® for Presbyopia (AOP), Air Optix® Aqua Multifocal (AOMF), and Air Optix® Aqua Single Vision (AOSV) lenses in patients with presbyopia. Methods: A single-blinded crossover trial was…

  4. New concepts in accommodation and presbyopia

    Edson dos Santos-Neto e Milton Ruiz AlvesRevista Brasileira de Oftalmologia2011citado por 2 artigos

    The authors conducted a review of classical and conflicting theories of accommodation and presbyopia. They make a critical comparison with the findings of magnetic resonance imaging (MRI) that have been developed in recent decades. Based on these studies, formulates a new approach on the subject, shifting the focus of…

  5. Evaluating peripheral retina: a cautionary note on miotics

    Rogil José de Almeida Torres, Andréa Luchini, Rogério João de Almeida Torres e mais 4Revista Brasileira de Oftalmologia2026

    ABSTRACT Objective: To underscore the critical importance of assessing the peripheral retina in all patients, especially those planning to use miotics. Methods: A retrospective and observational study was conducted at a single ophthalmological medical center, using records from the International Classification of…

  6. Objective and subjective visual outcome comparison analysis of two diffractive presbyopic correcting intraocular lenses

    Maria Carolina Zanata, César Vilar, Bernardo Kaplan Moscovici e mais 10Revista Brasileira de Oftalmologia2025

    ABSTRACT This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance…

  7. Dysfunctional lens syndrome: a prospective review

    Jorge Selem Haddad, Karolinne Maia Rocha, George Oral Waring IV e mais 2Revista Brasileira de Oftalmologia2021

    ABSTRACT The term dysfunctional lens syndrome has gained acceptance in the field and encompasses natural changes due to aging of crystalline lens. The evolution of diagnostic devices has been a key factor in better staging, understanding and characterizing of these degenerative changes. Even with these technological…

  8. Clinical experience after tetrafocal intraocular lens implantation “PANOPTIX”

    Miguel Ángel Ibáñez-Hernández, Ricardo Acosta-González, Mariana Mayorquín-Ruiz e mais 2Revista Brasileira de Oftalmologia2020

    Abstract Purpose: To assess long, intermediate and near uncorrected visual acuity after a tetrafocal diffractive intraocular lens implantation, presence of dystopic phenomenon and patient satisfaction after surgery. Methods: Retrospective, observational study performed in Puerta de Hierro Specialties Hospital, in…

  9. Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

    Daniel Monsálvez-Romín, Alberto Domínguez-Vicent, José. J. Esteve-Taboada e mais 2Arquivos Brasileiros de Oftalmologia2019

    ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean…

  10. Complete depigmentation of a small aperture corneal inlay implanted for compensation of presbyopia

    Mauro Campos, Sandra Beer, Eliane Mayumi Nakano e mais 3Arquivos Brasileiros de Oftalmologia2017

    ABSTRACT We describe a case of late-onset remarkable depigmentation of a small aperture corneal inlay implanted for presbyopia compensation. The patient was a participant in a clinical trial designed to evaluate the safety and efficacy of the AcuFocusTM ACU-10R160, which is a 10 µm-thick polyimide film tinted with an…

  11. An evaluation of estimation methods for determining addition in presbyopes

    Leonardo Catunda Bittencourt, Milton Ruiz Alves, Daniel Oliveira Dantas e mais 2Arquivos Brasileiros de Oftalmologia2013

    PURPOSE: The optical correction of presbyopia must be handled individually. Our aim was to compare the methods used in addition to the refractive near vision, with the final addition used in presbyopic patients. METHODS: Eighty healthy subjects with a mean age of 49.7 years (range 40 to 60 years) were studied…

  12. Comparative study of the blinking time between young adult and adult video display terminal users in indoor environment

    Tânia Mara Cunha Schaefer, Arthur Rubens Cunha Schaefer, Fernando Cesar Abib e mais 1Arquivos Brasileiros de Oftalmologia2009

    OBJECTIVE: Investigate the average blinking time in conversation and in Video Display Terminal use of young adults and adults in the presbyopic age group. METHODS: A transversal analytical study in a readily accessible sample consisting of Volkswagen do Brasil - Curitiba, Paraná employees was performed. The cohort…