acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “PVC membrane”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. PVC MEMBRANES PREPARED VIA NON-SOLVENT INDUCED PHASE SEPARATION PROCESS

    Liana F. Padilha e Cristiano P. BorgesBrazilian Journal of Chemical Engineering2019

    ABSTRACT Polyvinylchloride (PVC) based membranes are prepared via a phase inversion method using N,N-dimethylacetamide (DMAc) as solvent and water as precipitation bath. Polyvinylpyrrolidone (PVP) and lithium nitrate (LiNO3) are used as additives. Experimental cloud point data and solution viscosity measurements are…

  2. In situ Nanostructured PVC/Silica Electrospun Membranes for Oil/Water Separation

    Letícia Matos Machavelli e Sérgio H. PezzinMaterials Research2025

    This study focused on the preparation of electrospun poly(vinyl chloride)/silica membranes featuring the in situ formation of modified silica nanodomains during the electrospinning process, using organosilane precursors, with the purpose to develop new adsorbents for oil-spill cleanup. The membranes were fabricated…

  3. Zinc(II) PVC-based membrane sensor based on 5,6-benzo-4,7,13,16,21,24- hexaoxa-1,10-diazabicyclo[8,8,8]hexacos-5-ene

    Hassan Ali Zamani, Mohammad Reza Ganjali e Mohammad Jan PooyamaneshJournal of the Brazilian Chemical Society2006

    The 5,6-benzo-4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo[8,8,8]hexacos-5-ene (BHDE) was used as an excellent ionophore in construction of a Zn(II) PVC-based membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 64.5% nitrobenzen (NB), 2.5% BHDE and 3% sodium…

  4. Ion recognition: synthesis of 2-methyl-2,4-di (2-thienyl)-2,3-dihydro-1H-1,5-benzodiazepine and its application in construction of a highly selective and sensitive Ag+ membrane sensors

    Mohammad Reza Ganjali, Parviz Norouzi, Taher Alizadeh e mais 1Journal of the Brazilian Chemical Society2006

    A highly selective and sensitive plasticized membrane sensor for Ag+ ions based on 2-methyl-2,4-di(2-thienyl)-2,3-dihydro-1H-1,5-benzodiazepine (MTHB) as membrane carrier was prepared. The sensor shows a linear dynamic range of 1.0 × 10-6 -1.0 × 10-1 mol L-1, with a Nernstian slope of (58.5±0.3) mV…

  5. Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative

    Mohammad Reza Pourjavid, Mohammad Rezaee, Majid Haji Hosseini e mais 1Química Nova2012

    A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2×10-8 M. Its response is independent of pH of the solution in…

  6. A selective PVC matrix assisted potentiometric sensor for the determination of hydroxyzine hydrochloride (HDH)

    N. Rajendra Prasad e C. SiddarajuPortugaliae Electrochimica Acta2022

    Abstract A membrane sensor using an ion association complex of hydroxyzine hydrochloride (HDH) with Orange II (ORG-II) dye, in a polyvinyl chloride (PVC) matrix, has been developed and used as a selective electrode for HDH quantification in pharmaceuticals. The sensor is suitable to determine 2.2 × 10-5 - 1.1 × 10-3…

  7. Anion recognition: fabrication of a highly selective and sensitive HPO4(2-) PVC sensor based on a oxo-molybdenum methyl-salen

    Mohammad Reza Ganjali, Parviz Norouzi, Nader Hatambeygi e mais 1Journal of the Brazilian Chemical Society2006

    A highly selective and sensitive monohydrogen phosphate (MHP) sensor has been fabricated by constructing a poly vinyl chloride (PVC) matrix membrane containing a new oxo-molybdenum methyl-salen (MS) as a neutral carrier, hexadecyltrimethyl ammonium bromide (HTAB) as a cationic additive, benzylacetate (BA) as a…

  8. A new homatropine potentiometric membrane sensor as a useful device for homatropine hydrobromide analysis in pharmaceutical formulation and urine: a computational study

    Mohammad Reza Ganjali, Zahra Memari, Siavash Riahi e mais 3Journal of the Brazilian Chemical Society2009

    Homatropine (Equipin, Isopto Homatropine) is an anticholinergic medication that inhibits muscarinic acetylcholine receptors and thus the parasympathetic nervous system. It is available as the hydrobromide or methylbromide salt. In this study, a potentiometric liquid membrane sensor for simple and fast determination of…

  9. Highly selective and sensitive membrane salicylate electrode based on complex of (1,8-diamino-3,6-dioxaoctane) nickel(II)

    M. Mazloum-Ardakani, P. Pourhakkak, M. Salavati-Niasari e mais 2Journal of the Brazilian Chemical Society2011

    The potentiometric response of salicylate electrode based on complex of (1,8-diamino-3,6-dioxaoctane) nickel(II) was studied. The complex of 1,8-diamino-3,6-dioxaoctane nickel(II) [Ni(DADOO)] was used as carrier into plasticized polyvinyl chloride (PVC) membrane. The influence of several variables was investigated in…

  10. Application of Membrane-Selective Electrodes for the Determination of Naftidrofuryl Oxalate in the Presence of Its Alkaline Degradant in Tablets and Plasma

    Samah S. Abbas, Hala E. Zaazaa, Mohamed R. El-Ghobashy e mais 2Portugaliae Electrochimica Acta2012

    Membrane selective electrodes were used to determine Naftidrofuryl Oxalate (NFL) in presence of its alkaline degradate (I). The membrane selective electrodes include construction of water insoluble ion-association complexes. These are NFL-tetraphenyl borate (NFL-TPB), NFL-reinikate (NFL-R). These complexes are used as…

  11. Development of Membrane Electrodes for the Specific Determination of Moexipril Hydrochloride in Dosage Forms and Biological Fluids

    F. Belal, F. H. Metwaly, K. M. Younes e mais 1Portugaliae Electrochimica Acta2009

    Three polyvinylchloride (PVC) membrane sensors for the determination of moexipril hydrochloride were prepared and characterized. The sensors are based on the use of the ion association complexes of moexipril cation with either ammonium reineckate (sensor 1) or tetraphenyl borate (sensor 2) or phosphotungistic acid…

  12. Fabrication of a new samarium(III) ion-selective electrode based on 3-{[2-oxo-1(2h)-acenaphthylenyliden]amino}-2-thioxo -1,3-thiazolidin-4-one

    Hassan Ali Zamani, Mohammad Reza Ganjali e Mehdi AdibJournal of the Brazilian Chemical Society2007

    This paper introduces the development of an original PVC membrane electrode, based on 3-{[2-oxo-1(2H)-acenaphthylenyliden]amino}-2-thioxo-1,3-thiazolidin-4-one (ATTO) which has revealed to be a suitable carrier for Sm3+ ions. The resulting data illustrated that the electrode shows a Nernstian slope of 19.3 &plusmn…

  13. A Novel Potentiometric Sensor for the Determination of Nimesulide

    K.G. Kumar, P. Augustine e S. JohnPortugaliae Electrochimica Acta2007

    A novel electrochemical sensor has been developed for the determination of nimesulide. The sensor is based on the NIM- molybdophosphoric acid (MPA) as the electroactive material in PVC matrix in presence of bis(2-ethyl hexyl) phthalate (BEP) as a plasticizer. The sensor showed a fast, stable, near Nernstian response…

  14. Synthesis of 4-amino-6-methyl-1,2,4-triazin-5-one-3-thione and its application in construction of a highly copper(II) ion-selective electrochemical sensor

    Hassan Ali Zamani, Ghadier Rajabzadeh, Ali Firouz e mais 1Journal of the Brazilian Chemical Society2005

    A highly Cu(II) ion-selective PVC membrane sensor based on 4-Amino-6-methyl-1,2,4-triazin-5-one-3-thione (AMTOT) as an excellent sensing material was developed. The electrode exhibits a linear dynamic range between 1.0×10-1 and 1.0×10-6 mol L-1, with a near Nernstian slope of 29.3 ± 0.6 mV per…

  15. PREPARATION AND CHARACTERIZATION OF THIN-FILM COMPOSITE REVERSE OSMOSIS MEMBRANE ON A NOVEL AMINOSILANE-MODIFIED POLYVINYL CHLORIDE SUPPORT

    Shahram T. Iranizadeh, M. Pourafshari Chenar, Mahdieh N. Mahboub e mais 1Brazilian Journal of Chemical Engineering2019

    ABSTRACT Herein, the influence of pure and modified polyvinyl chloride (PVC) support layers on the performance of thin-film composite (TFC) membranes was investigated in water desalination. Accordingly, the PVC support was modified using (3-Aminopropyl) triethoxysilane (APTES) through bulk modification. The supports…

  16. High Sensitive and Selective Hydrogen Phosphate ISFET Based on Polyvinyl Chloride Membrane

    S. Hidouri, Z. M. Baccar, A. Errachid e mais 1Portugaliae Electrochimica Acta2015

    The present work describes the preparation and characterization of polyvinyl chloride membrane doped with methyl-salin ionophore. This electrode was successfully used for selectivity and high sensibility of monohydroxiphosphate in aqueous solution. 1 μM detection limit of mono-hydrogen phosphate was obtained by using…

  17. Novel neodymium(III) membrane sensor based on N-(2-Furylmethylene)pyridine-2,6-diamine

    Parviz Norouzi, Mohammad Reza Ganjali, Asieh Ahmadalinezhad e mais 1Journal of the Brazilian Chemical Society2006

    We found that N-(2-furylmethylene) pyridine-2,6-diamine (FPD) can be used as an excellent ionophore in the construction of a novel neodymium(III) poly(vinyl chloride) (PVC)-based membrane sensor. A membrane composition of 33% poly (vinyl chloride), 59% nitrobenzene (NB), 6% FPD, and 2% potassium tetrakis…