acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Micro-beam”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Study Neo-Hookean and Yeoh Hyper-Elastic Models in Dielectric Elastomer-Based Micro-Beam Resonators

    Saeed Danaee Barforooshi e Ardeshir Karami MohammadiLatin American Journal of Solids and Structures2016citado por 2 artigos

    Abstract Micro-bridge resonator with dielectric elastomer that is sandwiched between two electrodes is studied here with geometric and material nonlinearity. Geometric nonlinearity is introduced with Von-Karman strain-displacement relationship. For material nonlinearity that is modeled rarely in articles, two…

  2. Nonlinear Forced Vibration Analysis of Dielectric-Elastomer Based Micro-Beam with Considering Yeoh Hyper-Elastic Model

    Ardeshir Karami Mohammadi e Saeed Danaee BarforooshiLatin American Journal of Solids and Structures2017

    Abstract The present study investigates nonlinear forced vibration of dielectric elastomer-based micro-beam. The nonlinear terms in beam equation are geometric and material one. Geometric nonlinearity is considered by von-Karman strain displacement relationship and the material nonlinearity is modeled with Yeoh…

  3. Study of squeeze film damping in a micro-beam resonator based on micro-polar theory

    Mina Ghanbari, Siamak Hossainpour e Ghader RezazadehLatin American Journal of Solids and Structures2015citado por 1 artigo

    In this paper, squeeze film damping in a micro-beam resonator based on micro-polar theory has been investigated. The proposed model for this study consists of a clamped-clamped micro-beam bounded between two fixed layers. The gap between the micro-beam and layers is filled with air. As fluid behaves differently in…

  4. Comparative evaluation of cone-beam CT equipment with micro-CT in the visualization of root canal system

    Bence Tamas Szabo, Levente Pataky, Regina Mikusi e mais 2Annali dell'Istituto Superiore di Sanità2012citado por 1 artigo

    The aim of this study was to compare three different cone-beam CT (CBCT) instruments used in dental clinical practice with micro-CT as gold standard. Three female monkeys’ (Macaca fascicularis) skulls were selected and scanned by the tested CBCT-s. The most apical visible root canal level on the CBCT images was used…

  5. Cone-beam and micro-computed tomography for the assessment of root canal morphology: a systematic review

    Caroline Cristina BORGES, Carlos ESTRELA, Daniel de Almeida DECURCIO e mais 3Brazilian Oral Research2020citado por 4 artigos

    Abstract This study presents an overview of the accuracy of cone beam computed tomography (CBCT) compared with micro-computed tomography (μCT) in the assessment of root canal morphology of extracted human permanent teeth. A database search in PubMed, PubMed Central, Embase, Scopus, Opengrey, Scielo and Virtual Health…

  6. Optimization of Planar Antenna Arrays Using the Firefly Algorithm

    Eduardo Yoshimoto e Marcos V. T. HecklerJournal of Microwaves, Optoelectronics and Electromagnetic Applications2019

    Abstract This paper describes the application of the Firefly Algorithm for the optimization of linear and planar antenna arrays. In order to demonstrate the potential of this technique, three applications are reported. The first one is the synthesis of a radiation pattern with isoflux distribution with a non-uniformly…

  7. Morphological investigation of Toxoplasma gondii in vivo by a multiple beam interference microscope

    H Medina, JM Barboza, H Urdaneta e mais 2Memórias do Instituto Oswaldo Cruz2001

    A recently developed technique, namely multiple beam interference microscopy, has been applied to investigate the morphology of the parasite Toxoplasma gondii for the first time. The interference pattern obtained from the multiple internal reflection of a T. gondii, sandwiched between a glass plate and a cover plate…

  8. Application of Iteration Perturbation Method in studying dynamic pull-in instability of micro-beams

    Hamid M. Sedighi, Farhang Daneshmand e Amin YaghootianLatin American Journal of Solids and Structures2014citado por 1 artigo

    In the present study, dynamic pull-in instability of electrostatically-actuated micro-beams is investigated through proposing the nonlinear frequency amplitude relationship. An approximate analytical expression of the fundamental natural frequency is presented by modern asymptotic approach namely Iteration…

  9. Dynamic pull-in instability of geometrically nonlinear actuated micro-beams based on the modified couple stress theory

    Hamid M. Sedighi, Maziar Chan-Gizian e Aminreza Noghreha-BadiLatin American Journal of Solids and Structures2014citado por 3 artigos

    This paper investigates the dynamic pull-in instability of vibrating micro-beams undergoing large deflection under electrosatically actuation. The governing equation of motion is derived based on the modified couple stress theory. Homotopy Perturbation Method is employed to produce the high accuracy approximate…

  10. Effect of the Blooming Artifact Reduction filter on the detection of voids in root canal fillings using cone-beam computed tomography images

    Airton Oliveira Santos-Junior, Rocharles Cavalcante Fontenele, Jáder Camilo Pinto e mais 6Brazilian Dental Journal2025

    Abstract This study evaluated the effectiveness of the blooming artifact reduction (BAR) filter (e-Vol DX Software, CDT, Bauru, SP, Brazil) for detecting voids in root canals filled with various sealers, using two CBCT devices and micro-CT as a reference. Twenty mandibular incisors with long-oval root canals were…

  11. Comparative evaluation of the accuracy of linear measurements between cone beam computed tomography and 3D microtomography

    Francesca Mangione, Deborah Meleo, Marco Talocco e mais 3Annali dell'Istituto Superiore di Sanità2013citado por 1 artigo

    OBJECTIVE: The aim of this study was to evaluate the influence of artifacts on the accuracy of linear measurements estimated with a common cone beam computed tomography (CBCT) system used in dental clinical practice, by comparing it with microCT system as standard reference. MATERIALS AND METHODS: Ten bovine bone…

  12. Design of Microstrip Antenna Array with Suppressed Back Lobe

    Eduardo S. Silveira, Daniel C. Nascimento, Alexis F. Tinoco-S. e mais 1Journal of Microwaves, Optoelectronics and Electromagnetic Applications2017

    Abstract A practical procedure to reduce the back lobe level of linear microstrip antenna arrays is presented in this paper. The novel concept consists in the design of the radiators asymmetrically positioned with respect to the ground plane. In order to validate this technique, a four-element linearly-polarized array…

  13. Application of Higher Order Hamiltonian Approach to the Nonlinear Vibration of Micro Electro Mechanical Systems

    S. Sadeghzadeh e A. KabiriLatin American Journal of Solids and Structures2016

    Abstract This paper implements the higher order Hamiltonian method to analyze an electrostatically actuated nonlinear micro beam-based micro electro mechanical oscillator. First, second and third approximate solutions are obtained, and the frequency responses of the system are compared with energy balance method…

  14. Large amplitude free vibration of micro/nano beams based on nonlocal thermal elasticity theory

    Yong-Gang Wang, Hui-Fang Song, Wen-Hui Lin e mais 1Latin American Journal of Solids and Structures2015

    Abstract This paper is concerned with the nonlinear free vibration of a heated micro/nano beam modeled after the nonlocal continuum elasticity theory and Euler-Bernoulli beam theory. The governing partial differential equations are derived from the Hamilton variational principle and von Kármán geometric nonlinearity…

  15. Effect of Weather Condition on QoCS Beam of Downlink Microwave Radio Signals for High-Definition Digital Terrestrial Link over Abuja, Nigeria

    Joseph S. Ojo, Akeem B. Rabiu e Sarki. John-MarcusJournal of Microwaves, Optoelectronics and Electromagnetic Applications2025

    Abstract High-Definition Digital Terrestrial Television (HDDTT) replaces analogue, requiring further research on propagation links due to atmospheric variables potentially disrupting signals during uplink and downlink reception. This study examines the impact of surface meteorological parameters on the downlink…

  16. Tomographic, microbiological and histological characterization of secondary apical periodontitis: case series

    Marla Mora-Carabalí, Adolfo Contreras, Patricia Rodríguez e mais 2Brazilian Dental Journal2023

    Abstract This case series included a tomographic, microbiological, and histopathological description of 15 secondary apical periodontitis (SAP) lesions obtained by apical microsurgery performed in 10 patients to better understand the etiology and pathogenesis of SAP. Preoperative tomographic analyses were performed…

  17. Nucleation and growth microstructural study of ti films on 304 SS substrates

    Rogério de Almeida Vieira e Maria do Carmo de Andrade NonoMaterials Research2004

    Coating of steel surfaces with titanium films has been studied with the objective to protect them against corrosion, and to create an intermediate film for CVD diamond and TiN film deposition. In this work, the nucleation, growth mechanisms and microstructural formation of the titanium films deposited on 304 stainless…

  18. Adaptive Wideband Beamforming Based on Digital Delay Filter

    Zeeshan Ahmad, Song Yaoliang e Qiang DuJournal of Microwaves, Optoelectronics and Electromagnetic Applications2016

    Abstract A novel adaptive wideband beamforming method is proposed, where beamforming is achieved by LMS based space-time adaptive filtering algorithm. Conventional broadband beamforming requires desired signal to be incident from the broadside i.e. direction normal to the array. The new method overcome this constraint…

  19. Development of high performance fiber reinforced cement composites (HPFRCC) for application as a transition layer of reinforced beams

    V. J. Ferrari, A. P. Arquez, J. B. de Hanai e mais 1Revista IBRACON de Estruturas e Materiais2014

    This study presents the development and behavior analysis of high performance fiber reinforced cement composites (HPFRCC). The describedmaterials were specifically developed for application as a transition layer: a repair layer that constitutes the stressed chord of reinforcedconcrete beams strengthened in flexure…