acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Micro analysis”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. A Brazilian cost-utility analysis of trabecular micro-bypass with iStent inject® for the treatment of open-angle glaucoma

    Ricardo Augusto Paletta Guedes, Camila Pepe Souza, Leticia Lucia dos Santos Dias e mais 3Revista Brasileira de Oftalmologia2022citado por 4 artigos

    ABSTRACT Purpose To evaluate the cost-utility of the iStent inject® for the treatment of mild-to-moderate open-angle glaucoma (OAG) within the Brazilian Unified Health System (SUS). Methods A Markov model was developed, in which the effectiveness outcome measure was the incremental cost-effectiveness ratio (ICER: R$ /…

  2. Thermal Analysis on the Milled Al+B2O3+Si+WO3 System to Synthesize Al2O3-WxSiy-WxBy Powders

    Afshin Amiri Moghaddam e Mahdi KalantarMaterials Research2020

    Composites including silicide of tungsten and boride of tungsten intermetallic compound as reinforced agents in alumina matrix have a good mechanical properties in low and high temperature (high friction resistance, strength, resin stance to creep and relatively high thermal shock resistance), moreover, they have…

  3. Characterization of iron ore pellets by multimodal microscopy and image analysis

    Reynel Martinez Castellanos, Julio César Álvarez Iglesias, Otávio da Fonseca Martins Gomes e mais 2REM - International Engineering Journal2018citado por 1 artigo

    Abstract A correlative approach employing optical microscopy and scanning electron microscopy is proposed for the quantification of phases and pores in iron ore pellets. Combining mosaic images covering the full cross-sections of pellets, obtained with both techniques, it is possible to improve the discrimination of…

  4. Navier Solution for Buckling Analysis of Size-Dependent Functionally Graded Micro-Plates

    H. Farahmand, S. S. Naseralavi, A. Iranmanesh e mais 1Latin American Journal of Solids and Structures2016

    Abstract In the present paper, buckling analysis of functionally graded rectangular micro-plates, on the basis of strain gradient theory with one length scale parameter is studied. Considering the Kirchhoff plate theory and the principle of minimum total potential energy, governing equations of micro-plate subjected…

  5. Thermal, Mechanical and Microstructural Analysis of Metakaolin Based Geopolymers

    Liuski Roger Caballero, Maria das Dores Macedo Paiva, Eduardo de Moraes Rego Fairbairn e mais 1Materials Research2019citado por 2 artigos

    In the present work, geopolymer matrices were developed by alkali activation of metakaolin, using NaOH and sodium silicate as activators. The samples of metakaolin and matrices were studied by thermal analysis (TGA/DTA) at temperatures between 22°C and 1000°C in a nitrogen atmosphere with a heating rate of 10°C/min…

  6. Rapid identification of microbial contaminants in pharmaceutical products using a PCA/LDA-based FTIR-ATR method

    Natália Monte Rubio de Brito e Felipe Rebello LourençoBrazilian Journal of Pharmaceutical Sciences2021

    Microbiological quality of pharmaceuticals is fundamental in ensuring efficacy and safety of medicines. Conventional methods for microbial identification in non-sterile drugs are widely used; however they can be time-consuming and laborious. The aim of this paper was to develop a chemometric-based rapid…

  7. A novel disposable electrochemical microcell: construction and characterization

    Humberto E. A. Ferreira, Daniela Daniel, Mauro Bertotti e mais 1Journal of the Brazilian Chemical Society2008

    An alternative technique for the fabrication of disposable electrochemical microcells containing working, reference and auxiliary electrodes on a single device is reported. The procedure is based on thermal-transfer of toner masks onto CD-R (recordable compact discs) gold surfaces to define the layout of the…

  8. Methods validation and analysis of Spirulina (Arthrospira platensis) microcystin contaminants by Enzyme-Linked Immunosorbent Assay (ELISA)

    Hana Aulia Sativa, Didah Nur Faridah e Nuri AndarwulanBrazilian Journal of Food Technology2024

    Abstract Spirulina (Arthrospira platensis) production dominates the global microalgae market due to its high nutritional value. Spirulina can be cultivated in ponds with quality control due to the possible growth of cyanotoxins like Microcystis sp. that produce microcystins. The Enzyme-Linked Immunosorbent Assay…

  9. Comprehensive Growth Analysis to Detect Optimal Time Point for Carotenoid Production: A Comparative Study in Spirulina subsalsa and Chlorella pyrenoidosa

    Sruthi Padmakumar Pillai, Sangeeta Atul Godbole, Rutwik Ravindra Manda Thengodkar e mais 1Brazilian Archives of Biology and Technology2025

    Abstract This study investigated the growth dynamics of Spirulina subsalsa and Chlorella pyrenoidosa under standardized phototrophic cultivation conditions to determine the optimal harvest time for maximum carotenoid yield. Both species were maintained at temperature (28℃-35℃), relative humidity (52%-55%), light…

  10. Influence of Root Canal Preparation on Formation of Dentinal Microcracks: A Systematic Review

    Alânia Dalla Valle, Lara Dotto, Renata Dornelles Morgental e mais 3Brazilian Dental Journal2020

    Abstract The effect of root canal preparation technique on microcrack initiation is a controversial issue. This systematic review aimed to assess the role of root canal preparation techniques with different kinematics (manual, rotary, reciprocating, adaptive, self-adjusting file) on microcrack initiation. In vitro and…

  11. Fixture-abutment connection surface and micro-gap measurements by 3D micro-tomographic technique analysis

    Deborah Meleo, Luigi Baggi, Michele Di Girolamo e mais 3Annali dell'Istituto Superiore di Sanità2012

    X-ray micro-tomography (micro-CT) is a miniaturized form of conventional computed axial tomography (CAT) able to investigate small radio-opaque objects at a-few-microns high resolution, in a nondestructive, non-invasive, and tri-dimensional way. Compared to traditional optical and electron microscopy techniques, which…

  12. Topography of Primary Molar Pulp Chamber Floor: A Scanning Electron Microscopy and Micro-Computed Tomography Analysis

    Ana Victória Lopes Bandeira, Marina de Deus Moura de Lima, Cacilda Castelo Branco Lima e mais 3Pesquisa Brasileira em Odontopediatria e Clínica Integrada2021citado por 1 artigo

    ABSTRACT Objective: To determine in vitro the frequency, shape, type, diameter, and patency of accessory canals in the primary molars pulp chamber floor. Material and Methods: Sixteen healthy primary molars were evaluated by micro-computed tomography and scanning electron microscopy. Descriptive analyses of the…

  13. Performance analysis of bacterial self-compacting concrete – workability, mechanical, durability and micro analysis

    Priyadharshini Vadamalai e Suresh Kumar ParamasivamMatéria (Rio de Janeiro)2024citado por 4 artigos

    ABSTRACT Concrete may develop micro cracks and contains pores, both of which are extremely undesirable since they allow water and other harmful chemicals to enter the material easily. The Bacterial Self Compacting (BSCC), which continually deposits calcite in concrete, is one efficient method for sealing fissures…

  14. Odontogenic gene expression profile of human dental pulp-derived cells under high glucose influence: a microarray analysis

    Sivaporn HORSOPHONPHONG, Hathaitip SRITANAUDOMCHAI, Siriruk NAKORNCHAI e mais 2Journal of Applied Oral Science2021

    Abstract Hyperglycemia, a major characteristic of diabetes, is considered to play a vital role in diabetic complications. High glucose levels have been found to inhibit the mineralization of dental pulp cells. However, gene expression associated with this phenomenon has not yet been reported. This is important for…

  15. Fast method of multi-elemental analysis of stream sediment samples by inductively coupled plasma-mass spectrometry (ICP-MS) with prior single-step microwave-assisted digestion

    Vibor RojeJournal of the Brazilian Chemical Society2011

    One-step microwave-assisted digestion procedures were investigated with the scope to obtain fast method for multi-elemental analysis of stream sediment samples by sector field inductively coupled plasma-mass spectrometry (SF-ICP-MS). As a model, certified reference material stream sediment (NCS DC 73309), produced by…

  16. Prophylactic central neck dissection and local recurrence in papillary thyroid microcarcinoma: a meta-analysis,

    Hui Su e Yujie LiBrazilian Journal of Otorhinolaryngology2019citado por 1 artigo

    Abstract Introduction: For papillary thyroid microcarcinoma patients, the reported incidence of lymph node metastasis is as high as 40%, and these occur mainly in the central compartment of the neck. Because these metastases are difficult to detect using ultrasonography preoperatively, some authors advocate routine…

  17. Thermal stability and microstructure characterization of MgAl2O4 nanoparticles synthesized by reverse microemulsion method

    Ping Fu, Wenzhong Lu, Wen Lei e mais 3Materials Research2013citado por 1 artigo

    Magnesium aluminate (MgAl2O4) spinel nanoparticles were synthesized by reverse microemulsion process in cyclohexane by using two kinds of surfactants, n-amyl alcohol as cosurfactant and mixture of aluminic/magnesic salt aqueous solution as basic reagents. The effects of surfactant types and titration methods on the…