acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Mechanical phenomena”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of high energy X-ray irradiation on the nano-mechanical properties of human enamel and dentine

    Xue LIANG, Jing Yang ZHANG, Iek Ka CHENG e mais 1Brazilian Oral Research2016citado por 4 artigos

    Abstract Radiotherapy for malignancies in the head and neck can cause common complications that can result in tooth damage that are also known as radiation caries. The aim of this study was to examine damage to the surface topography and calculate changes in friction behavior and the nano-mechanical properties…

  2. Erosive Potential of Cola-Type Soft Drinks on the Surface of Restorative Materials: In Vitro Study

    Marília Gabriela Corrêa Momesso, Kelly Maria Silva Moreira, Renata Cristiane da Silva e mais 2Pesquisa Brasileira em Odontopediatria e Clínica Integrada2025

    ABSTRACT Objective: To evaluate the Knoop hardness of two types of glass ionomer cement - VitroMolar (VM) and Riva Self Cure (RSC), as well as the composite resin Z350 (CR), when exposed to two Cola-type soft drinks. Materials and Methods: Forty specimens were prepared using a matrix. After placing a polyester strip…

  3. Effect of removal and reinsertion of force-closed stems on deformation of total hip arthroplasty

    Sandro Griza, Luiz Sérgio Marcelino Gomes, André Cervieri e mais 1Revista Brasileira de Ortopedia2016

    ABSTRACT OBJECTIVES: This study investigated removal of a force-closed stem, done in order to improve acetabular exposure during revision, with reinsertion afterwards. It is unknown how much this procedure modifies the stem/cement interface. METHODS: Three tapered stem models were implanted into composite femurs…

  4. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    Manoela Fávaro Francisconi, Guilherme Janson, José Fernando Castanha Henriques e mais 1Journal of Applied Oral Science2016citado por 3 artigos

    ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual…

  5. Analysis of resistance to fatigue between straight solid and anatomic abutments of Morse taper system

    Vanessa Tavares de GOIS-SANTOS, Cleverson Luciano TRENTO, Silvando Vieira dos SANTOS e mais 3Revista de Odontologia da UNESP2016

    Abstract Background The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method We used 37…

  6. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Rodrigo Hitoshi Higa, Nayara Thiago Semenara, José Fernando Castanha Henriques e mais 3Dental Press Journal of Orthodontics2016

    ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and…

  7. Migration and strains induced by different designs of force-closed stems for THA

    Sandro Griza, Luiz Sérgio Marcelino Gomes, André Cervieri e mais 1Revista Brasileira de Ortopedia2015

    ABSTRACT Objectives: Subtle differences in stem design can result in different mechanical responses of the total hip arthroplasty. Tests measuring migration of the stem relative to the femur, as well as the strains in the cement mantle and on the femur can detect different mechanical behavior between stems. Methods…

  8. Strain analysis of different diameter Morse taper implants under overloading compressive conditions

    Carolina Guimarães CASTRO, Karla ZANCOPÉ, Crisnicaw VERÍSSIMO e mais 2Brazilian Oral Research2015citado por 1 artigo

    The aim of this study was to evaluate the amount of deformation from compression caused by different diameters of Morse taper implants and the residual deformation after load removal. Thirty Morse taper implants lacking external threads were divided into 3 groups (n = 10) according to their diameter as follows: 3.5…

  9. Physicochemical Properties of a Methacrylate-Based Dental Adhesive Incorporated with Epigallocatechin-3-gallate

    Jiovanne Rabelo Neri, Monica Yamauti, Victor Pinheiro Feitosa e mais 3Brazilian Dental Journal2014citado por 2 artigos

    This study aimed to evaluate the influence of epigallocatechin-3-gallate (EGCG) incorporation on the physicochemical properties of a methacrylate-based dental adhesive. EGCG was added to Adper Easy One (3M-ESPE) except in control group, to obtain concentrations of 0.01% w/w and 0.1% w/w of EGCG-doped adhesives. For…

  10. Effect of light sources and curing mode techniques on sorption, solubility and biaxial flexural strength of a composite resin

    Andreia Assis Carvalho, Francine do Couto Lima Moreira, Rodrigo Borges Fonseca e mais 4Journal of Applied Oral Science2012citado por 3 artigos

    Adequate polymerization plays an important role on the longevity of the composite resin restorations. OBJECTIVES: The aim of this study was to evaluate the effect of light-curing units, curing mode techniques and storage media on sorption, solubility and biaxial flexural strength (BFS) of a composite resin. MATERIAL…

  11. An Investigation into Mechanisms of Loss of Safe Basins in a 2 D.O.F. Nonlinear Oscillator

    J. R. de Souza Junior e M. L. RodriguesJournal of the Brazilian Society of Mechanical Sciences2002

    In this work we consider the transient stability of coupled motions of a 2 D.O.F. nonlinear oscillator that can represent, for example, the motions of a sea vessel under the action of trains of regular lateral waves. Instability is studied as the escape of the system from a safe potential well. The set of initial…

  12. The Phenomena Involved in the Thermal-dependent Tensile Mechanical Tests of Premium Rail Steel

    João Vitor de Oliveira Cordeiro, Henrique Boschetti Pereira, Luiz Felipe Bauri e mais 8Materials Research2025

    This study investigates the microstructural phenomena involved in the temperature-dependent mechanical properties of the Premium rail steel through tensile tests at various temperatures. Dilatometry and scanning electron microscopy were used to characterize the materials before and after tensile tests at different…

  13. BASKETBALL COURSE OPTIMIZATION BASED ON MECHANICAL CHARACTERISTICS

    Yadong Ren e Lei FengRevista Brasileira de Medicina do Esporte2023

    ABSTRACT Introduction Currently, college basketball lacks evaluation criteria, making the teaching of many classes reduced to the study of superficial movements, preventing the optimization of the sport’s intrinsic mechanical characteristics. Objective Optimize the methodology of the basketball course by implementing…

  14. A methodology and computational system for the simulation of fluid-structure interaction problem

    A. R. E. Antunes, P. R. M. Lyra e R. B. WillmersdorfJournal of the Brazilian Society of Mechanical Sciences and Engineering2005

    In this paper a flexible finite element computational tool developed to investigate fluid-structure interaction applications in two dimensions is described. We consider problems which can be modelled as a viscous incompressible fluid flow and a rigid body-spring system interacting nonlinearly with each other. The…

  15. Monoaxial Mechanical Tests on Porcino Knee Ligaments

    Rodrigo Ribeiro Pinho Rodarte, João Antônio Matheus Guimarães, Brenno Tavares Duarte e mais 2Revista Brasileira de Ortopedia2023

    Abstract The failure of ligament reconstruction has different risk factors, among which we can highlight the period before its incorporation, which is a mechanically vulnerable period. Loss of resistance over time is a characteristic of living tissues. Dissection with bone insertions of the cruciate ligaments of…

  16. Cross-sectional Evaluation of the Mechanical Axis and Other Angular Parameters of the Lower Limbs in Male Professional Soccer Players

    Jean Klay Santos Machado, Eurineto Gomes do Nascimento e Erik Silva de MenezesRevista Brasileira de Ortopedia2026

    Abstract Objective To evaluate themechanical axis and angular parameters of the lower limbs in professional soccer players, relating themto age, limb dominance, and field position. Methods The present cross-sectional study included 102 male athletes from a Brazilian professional soccer team. Full-length radiographs in…

  17. Musculoskeletal computational analysis on muscle mechanical characteristics of drivers’ lumbar vertebras and legs in different sitting postures

    Fei Gao, Shi Zong, Zhi-Wu Han e mais 2Revista da Associação Médica Brasileira2020citado por 1 artigo

    SUMMARY Using computer-aided engineering (CAE) in the concept design stage of automobiles has become a hotspot in human factor engineering research. Based on human musculoskeletal biomechanical computational software, a seated human-body musculoskeletal model was built to describe the natural sitting posture of a…

  18. Impact of radiotherapy in chemical composition and mechanical properties of human cervical dentin: an in vitro study

    Renata Borges RODRIGUES, Allyne Jorcelino Daloia de CARVALHO, Bruna Vanessa FELIPE E SILVA e mais 2Journal of Applied Oral Science2025

    Abstract Ionizing radiation directly affects hard dental tissues, compromising the dental structure, which results in damage to dentin collagen fibers and impacts the integrity of the dentin-enamel junction (DEJ). Objective To evaluate the effects of radiotherapy on the chemical composition and mechanical properties…

  19. Mechanical analysis of femoral neck fracture fixation with dynamic condylar screw in synthetic bone

    Anderson Freitas, Rafael Almeida Maciel, Renato De Almeida Lima e mais 2Acta Ortopédica Brasileira2014

    Objective: To analyze statistically results in biomechanical testing of fixation of femoral neck Pauwels type III fractures, on synthetic bone, with dynamic condylar screw (DCS) and control group.Methods: Ten synthetic bones of a national brand were used. Test Group: fixation was performed after osteotomy at 70o tilt…

  20. Mechanical Study of the Properties of Sutures used in Orthopedics Surgeries

    Leandro Cardoso Gomide, Dagoberto de Oliveira Campos, Cleudmar Amaral Araújo e mais 3Revista Brasileira de Ortopedia2019citado por 1 artigo

    Abstract Objective To evaluate the mechanical properties of sutures commonly used in orthopedic surgeries, characterizing their behavior through tensile tests and determining which one has greater mechanical strength. Method Tensile tests of different sutures were performed in a mechanical testing machine BME 10 kN…