acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Mario Cesar U. Araujo”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. A micro-flow-batch analyzer using webcam for spectrophotometric determination of Ortho-phosphate and aluminium(III) in tap water

    Marcelo B. Lima, Stéfani I. E. Andrade, Maria S. Silva Neta e mais 3Journal of the Brazilian Chemical Society2014

    In this work, a micro-flow-batch analyzer (µFBA) using webcam for spectrophotometric determination of ortho-phosphate and aluminium(III) in tap water is proposed. PO4(3-) and Al3+ determinations were performed by employing molybdenum blue and quecertin methods, respectively. In order to build linear analytical curves…

  2. Using webcam, CdTe quantum dots and flow-batch system for automatic spectrofluorimetric determination of N-Acetyl-L-cysteine in pharmaceutical formulations

    Marcelo B. Lima, Inakã S. Barreto, Stéfani Iury E. Andrade e mais 2Journal of the Brazilian Chemical Society2014

    The combination of a flow-batch system, quantum dots (QDs) and webcam as detector for the automatic spectrofluorimetric determination of N-acetyl-L-cysteine (NAC) in pharmaceutical formulations is proposed. NAC generates surface interactions that result in enhanced QD fluorescence intensity, which is proportional to…

  3. Um sistema microcontrolado para o monitoramento on-line, in situ e remoto de pH, condutividade e temperatura de águas

    Renato Sousa Lima, Vagner Bezerra dos Santos, Thiago Brito Guerreiro e mais 2Química Nova2011

    A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water…

  4. Influence of wavelet transform settings on NIR and MIR spectrometric analyses of diesel, gasoline, corn and wheat

    Luiz Alberto Pinto, Roberto K. H. Galvão e Mário César U. AraújoJournal of the Brazilian Chemical Society2011

    This paper investigates the influence of wavelet family, length and number of resolution levels on the performance of multivariate calibration models obtained in the wavelet domain. Twenty-one physical and chemical properties of diesel, gasoline, corn and wheat were determined by near/mid infrared spectrometry…

  5. Effect of the subsampling ratio in the application of subagging for multivariate calibration with the successive projections algorithm

    Arlindo R. Galvão Filho, Roberto K. H. Galvão e Mário César U. AraújoJournal of the Brazilian Chemical Society2011

    This paper concerns the effect of the subsampling ratio on the subagging approach for multiple linear regression with variable selection by the successive projections algorithm. Investigations involving simulated data, as well as near-infrared spectrometric determination of moisture and protein in wheat and…

  6. Análise screening de vinhos empregando um analisador fluxo-batelada, espectroscopia UV-VIS e quimiometria

    Jaqueline Azevedo Nascimento, Amália Geíza Gama Dionísio, Elaine Cristina Lima do Nascimento e mais 2Química Nova2010

    A simple, robust, versatile, high analytical frequency method was proposed to check if a sample of wine is within the range of standards set by the manufacturer, using the UV-VIS spectroscopy, multivariate analysis and a flow-batch analyzer. Two hundred and fifty-two samples of wines were analyzed. The results from…

  7. Classificação periódica: um exemplo didático para ensinar análise de componentes principais

    Wellington da Silva Lyra, Edvan Cirino da Silva, Mario Cesar Ugulino de Araújo e mais 2Química Nova2010citado por 11 artigos

    A dataset of chemical properties of the elements is used herein to introduce principal components analysis (PCA). The focus in this article is to verify the classification of the elements within the periodic table. The reclassification of the semimetals as metals or nonmetals emerges naturally from PCA and agrees with…

  8. Improving the computational efficiency of the successive projections algorithm by using a sequential regression implementation: a case study involving nir spectrometric analysis of wheat samples

    Anderson S. Soares, Arlindo R. Galvão Filho, Roberto K. H. Galvão e mais 1Journal of the Brazilian Chemical Society2010

    This short report proposes a sequential regression implementation for the successive projections algorithm (SPA), which is a variable selection technique for multiple linear regression. An example involving the near-infrared determination of protein in wheat is presented for illustration. The resulting model…

  9. Multi-core computation in chemometrics: case studies of voltammetric and NIR spectrometric analyses

    Anderson da Silva Soares, Roberto K. H Galvão, Mário César U Araújo e mais 2Journal of the Brazilian Chemical Society2010

    The application of sophisticated chemometrics techniques to large datasets has been made possible by continuing technological improvements in off-the-shelf computers. Recently, such improvements have been mainly achieved by the introduction of multi-core processors. However, the efficient use of multi-core hardware…

  10. Wavelet-Based determination of Cu and Pb in water samples using potentiometric stripping analysis with a Lab-Made potentiostat

    Valdomiro L. Martins, Roberto K. Harrop Galvão, Mário César U. de Araújo e mais 1Journal of the Brazilian Chemical Society2009citado por 1 artigo

    This paper demonstrates the possibility of simultaneously determining lead and copper in mineral, river and tap water by potentiometric stripping analysis using a low-cost lab-made potentiostat and a wavelet-based signal processing method. Pb(II) and Cu(II) concentrations were found to be in the range 3-7 µg L-1…

  11. Recomendações para calibração em Química Analítica parte 2: calibração multianalito

    Maria Fernanda Pimentel, Roberto Kawakami Harrop Galvão e Mário César Ugulino de AraújoQuímica Nova2008

    This paper is a translation of an IUPAC document by K. Danzer, M. Otto and L. A. Currie (Pure Appl. Chem., 2004, 76(6), 1215-1225). Its goal is to establish a uniform and meaningful standard for terminology (in Portuguese), notation, and formulation concerning multispecies calibration in analytical chemistry…

  12. Cross-validation for the selection of spectral variables using the successive projections algorithm

    Roberto Kawakami Harrop Galvão, Mário César Ugulino Araújo, Edvan Cirino Silva e mais 3Journal of the Brazilian Chemical Society2007

    This work compares the use of a separate validation set and leave-one-out cross-validation to guide the selection of variables in the Successive Projections Algorithm (SPA) for multivariate calibration. Two case studies involving diesel and corn analysis by NIR spectrometry are presented. A graphical interface for SPA…

  13. Um fotômetro multi-led microcontrolado, portátil e de baixo custo

    Edvaldo da Nóbrega Gaião, Everaldo Paulo de Medeiros, Wellington da Silva Lyra e mais 4Química Nova2005

    A microcontrolled, portable and inexpensive photometer is described. It uses six light-emitting diodes (LEDs) as radiation sources and a phototransistor as detector, as well as a microcontroller (PIC - Programmable Controller of Interruption). This device provided total autonomy to the proposed photometer, which was…

  14. Uma interface lab-made para aquisição de sinais analógicos instrumentais via porta paralela do microcomputador

    Edvaldo da Nóbrega Gaião, Everaldo Paulo de Medeiros, Wellington da Silva Lyra e mais 3Química Nova2004

    A lab-made interface for acquisition of instrumental analog signals between 0 and 5 V at a frequency up to 670 kHz at the parallel port of a microcomputer is described. Since it uses few and small components, it was built into the connector of a printer parallel cable. Its performance was evaluated by monitoring the…

  15. An automatic flow-batch standard-addition method for sodium determination in alcohol fuel by flame photometry

    Luciano F. de Almeida, Valdomiro L. Martins, Edvan C. da Silva e mais 2Journal of the Brazilian Chemical Society2003

    The Brazilian Regulatory Agency for fuel production and commercialization requires that the sodium concentration in alcohol fuel should be determined by flame photometry and that the analytical curves should be obtained with matrix-matched standards. Notwithstanding, this methodology can produce inexact results…

  16. Recomendações para calibração em química analítica: parte I. Fundamentos e calibração com um componente (calibração univariada)

    Benício de Barros Neto, Maria Fernanda Pimentel e Mário César Ugulino AraújoQuímica Nova2002citado por 4 artigos

    This paper is a translation from IUPAC nomenclature document by K. Danzer and L. A. Currie (Pure Appl. Chem., 1998, 70(4), 993-1014). Its goal is to establish an uniform and meaningful approach to terminology (in Portuguese), notation, and formulation for calibation in analytical chemistry. In this first part, general…

  17. Estudo comparativo sobre filtragem de sinais instrumentais usando transformadas de Fourier e Wavelet

    Roberto Kawakami Harrop Galvão, Mário César Ugulino de Araújo, Teresa Cristina Bezerra Saldanha e mais 2Química Nova2001

    A comparative study of the Fourier (FT) and the wavelet transforms (WT) for instrumental signal denoising is presented. The basic principles of wavelet theory are described in a succinct and simplified manner. For illustration, FT and WT are used to filter UV-VIS and plasma emission spectra using MATLAB software for…

  18. Análise multicomponente simultânea por espectrofotometria de absorção molecular UV-VIS

    Teresa Cristina B. Saldanha, Mário César U. de Araújo e Benício de Barros NetoQuímica Nova1999

    This review presents the evolution of simultaneous multicomponent analysis by absorption spectrophotometry in the ultraviolet and visual regions in terms of some qualitative and quantitative analysis techniques, otimization methods, as well as applications and modern trends.

  19. Escassez de engenheiros no Brasil? uma proposta de sistematização do debate

    Leonardo Melo Lins, Mario Sergio Salerno, Bruno César Araújo e mais 3Novos estudos CEBRAP2014

    Buscamos ordenar e qualificar uma discussão contemporânea, relativa a uma possível escassez de engenheiros na sociedade brasileira. Com base na literatura, elencamos as hipóteses que levariam à caracterização de escassez e procuramos argumentos baseados em dados para discutir tais hipóteses. Os dados não corroboram a…

  20. Emprego do carvão ativado para remoção de cobre em cachaça

    Annete de J. Boari Lima, Maria das Graças Cardoso, Mário César Guerreiro e mais 1Química Nova2006citado por 9 artigos

    Copper content is of great concern among sugarcane-spirit producers. It is released from copper-made distillers, during the distillation process. Activated carbon has been used to remove copper. However, depending on the amount of carbon and the duration of reaction, it can also remove higher alcohols and esters…