acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Light-curing units”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Abrasion resistance of composites polymerized by light-emitting diodes (LED) and halogen light-curing units

    Janisse Martinelli, Fernanda de Carvalho Panzeri Pires-de-Souza, Luciana Assirati Casemiro e mais 2Brazilian Dental Journal2006citado por 2 artigos

    This study compared the abrasion resistance of direct composite resins cured by light-emitting diodes (LED) and halogen light-curing units. Twenty specimens (12 mm in diameter; 1.0 mm thick) of each composite resin [TPH (Dentsply); Definite (Degussa); Charisma (Heraus Kulzer)] were prepared using a…

  2. Prototype of a new tip developed to be coupled to dental light-curing units for optimizing bonding of orthodontic brackets and accessories

    Sergio Luiz Mota Júnior, Márcio José da Silva Campos, Marco Abdo Gravina e mais 2Dental Press Journal of Orthodontics2013

    OBJECTIVE: development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories, and test its efficacy in an in vitro mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of…

  3. Effect of light-curing units, post-cured time and shade of resin cement on knoop hardness

    Rogério Vieira Reges, Ana Rosa Costa, Américo Bortolazzo Correr e mais 4Brazilian Dental Journal2009citado por 8 artigos

    The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the…

  4. Influence of Sealer and Light-Curing Units on Push-Out Bond Strength Of Composite Resin to Weakened Roots

    Adriana Corrêa de Lima, Fuad Jacob Rached-Junior, Natália Spadini de Faria e mais 5Brazilian Dental Journal2016citado por 1 artigo

    Abstract The aim of this study was to assess the influence of sealer and light-curing unit on regional bond strength of resin composite to the weakened roots. Ninety roots of incisors were experimentally weakened, subjected to biomechanical preparation and filled with either Endofill, AH Plus or MTA Fillapex The roots…

  5. An Evaluation of the Light Output from 22 Contemporary Light Curing Units

    Carlos José Soares, Monise de Paula Rodrigues, Laís Rani Sales Oliveira e mais 5Brazilian Dental Journal2017citado por 8 artigos

    Abstract This study measured the radiant power (mW), irradiance (mW/cm2) and emission spectra (mW/cm2/nm) of 22 new, or almost new, light curing units (LCUs): - Alt Lux II, BioLux Standard, Bluephase G2, Curing Light XL 3000, Demetron LC, DX Turbo LED 1200, EC450, EC500, Emitter C, Emitter D, KON-LUX, LED 3M ESPE, Led…

  6. Effect of light-activation with different light-curing units and time intervals on resin cement bond strength to intraradicular dentin

    Maria Eleonora Miguel-Almeida, Mario Lucio da Costa Azevedo, Fuad Abi Rached-Júnior e mais 3Brazilian Dental Journal2012citado por 5 artigos

    The aim of this study was to assess the bond strength of a resin cement to intraradicular dentin varying the light-curing unit and the moment at which the light was applied. Post spaces of endodontically treated canines were prepared. The roots were distributed into 6 groups (n=10) according to the light-curing unit…

  7. Effect of different light curing methods on mechanical and physical properties of resin-cements polymerized through ceramic discs

    Isil Cekic-nagas e Gulfem ErgunJournal of Applied Oral Science2011citado por 3 artigos

    OBJECTIVE: The aim of this study was to compare the polimerization ability of three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) and their exposure modes (high-intensity and soft-start) by determination of microhardness, water sorption and solubility, and diametral…

  8. Effect of light curing unit on resin-modified glass-ionomer cements: a microhardness assessment

    Daniela Francisca Gigo Cefaly, Liliam Lucia Carrara Paes de Mello, Linda Wang e mais 2Journal of Applied Oral Science2009citado por 3 artigos

    OBJECTIVE: To evaluate the microhardness of resin-modified glass-ionomer cements (RMGICs) photoactivated with a blue light-emitting diode (LED) curing light. MATERIAL AND METHODS: Thirty specimens were distributed in 3 groups: Fuji II LC Improved/GC (RM1), Vitremer/3M ESPE (RM2) and Filtek Z250/ 3M ESPE (RM3). Two…

  9. Evaluation of light output from light-curing units used in a public oral health service in Brazil

    Laryssa Silva da Cunha, Airin Karelys Avendaño Rondon, Maryuri del Carmen Macias Bautista e mais 5Brazilian Dental Journal2026

    Abstract This observational field study aimed to evaluate the radiant power (mW), emission spectra (mW/cm²/nm), irradiance (mW/cm²), and the light tip integrity of 40 light-curing units (LCUs) used in 16 public oral health service units in the city of Uberlândia, Minas Gerais, Brazil. The radiant power and emission…

  10. Wavelength-dependent cytokine modulation in metabolically stressed fibroblasts

    Samantha Bender, Sharanya Singh, Lauren Lamoutte e mais 4Journal of Applied Oral Science2026

    Abstract Objective To investigate the effects of blue- and red-light irradiation on MTT reduction and cytokine concentrations in metabolically stressed L929 fibroblast-like cells, as an in vitro model to explore wavelength-associated biological responses relevant to light exposure during restorative treatments…

  11. Effect of thickness and shade of CAD/CAM composite on the light transmission from different light-curing units

    Julia Dantas MAZÃO, Maria Tereza Hordones RIBEIRO, Stella Sueli Lourenço BRAGA e mais 3Brazilian Oral Research2023

    Abstract The thickness and shade of a restoration will affect the transmission of light from the light-curing unit (LCU). This study determined the power (mW), spectral radiant power (mW/nm), and beam profile of different LCUs through various thicknesses and shades of a CAD-CAM resin composite (BRAVA Block, FGM). Five…

  12. Accuracy of Irradiance and Power of Light-Curing Units Measured With Handheld or Laboratory Grade Radiometers

    Marcelo Giannini, Carolina Bosso André, Vanessa Cavalli Gobbo e mais 1Brazilian Dental Journal2019

    Abstract This study measured and compared exitance irradiance and power of 4 commercial dental light-curing units (LCU) (Elipar S10, Elipar DeepCure-S, Corded VALO and Bluephase Style) using different types of radiometers. The devices used to analyze the LCU were classified as either handheld analog (Henry Schein…

  13. Irradiance and Radiant Exposures Delivered by LED Light-Curing Units Used by a Left and Right-Handed Operator

    Carlos José Soares, Gabriel Felipe de Bragança, Renata Afonso da Silva Pereira e mais 5Brazilian Dental Journal2018citado por 2 artigos

    Abstract The combination of the restoration location, the hand preference of the operator using the light-curing unit (LCU), and the design of the LCU all can have an impact on the amount of the light delivered to the restoration. To evaluate the effect of left-handed or right-handed users, the position of the…

  14. Impact of different resin materials and light-curing units on adhesive performance of fiber posts

    Natália Spadini de Faria, Laís Lima Pelozo, Luciana Martins D’Elboux Guimarães-Elias e mais 4Brazilian Dental Journal2025

    Abstract This study evaluated the effect of different light-curing units on the conversion degree of resin materials used for luting glass fiber posts and the bond strength to root dentin. One hundred bovine roots received endodontic treatment and were randomly assigned to five groups (n = 10) according to the luting…

  15. Influence of composite restorative materials and light-curing units on diametrical tensile strength

    Maria Cecília Caldas Giorgi Tolosa, Luís Alexandre Maffei Sartini Paulillo, Marcelo Giannini e mais 2Brazilian Oral Research2005citado por 3 artigos

    The aim of this study was to evaluate the diametrical tensile strength (DTS) of three light-curing photo-activated composites with two different light curing units (LCU). Three types of dental restorative composites were used in this study: micro filled A110 (3M Espe); P60 (3M Espe) for posterior restorations, and…

  16. Effect of light-curing units in shear bond strength of metallic brackets: an in vitro study

    Luciana Borges Retamoso, Niége Michelle Lazzari Onofre, Luciane Hann e mais 1Journal of Applied Oral Science2010

    OBJECTIVES: To determine the influence of the light curing units on the shear bond strength of orthodontic brackets. MATERIAL AND METHODS: Seventy-two premolars were divided into six groups (n=12): Group I: brackets bonded with Transbond and polymerization with halogen light; Group II: Transbond and LED; Group III…

  17. Influence of different light-curing units on the surface roughness of restorative materials: in situ study

    Juliane Cristina Ciccone-Nogueira, Wanessa Christine de Souza-Zaroni, Michelle Alexandra Chinelatti e mais 1Materials Research2007

    The aim of this study was to evaluate the influence of different light sources (LED and Halogen lamp) on the roughness (superficial) of composite resin (Filtek Z250, Filtek P60, Charisma and Durafill) varying post-irradiation times, in an in situ experiment. For this purpose, 80 specimens were made in polyurethane…

  18. Effect of light-curing units and activation mode on polymerization shrinkage and shrinkage stress of composite resins

    Lawrence Gonzaga Lopes, Eduardo Batista Franco, José Carlos Pereira e mais 1Journal of Applied Oral Science2008citado por 6 artigos

    The aim of this study was to evaluate the polymerization shrinkage and shrinkage stress of composites polymerized with a LED and a quartz tungsten halogen (QTH) light sources. The LED was used in a conventional mode (CM) and the QTH was used in both conventional and pulse-delay modes (PD). The composite resins used…

  19. UV-Vis spectrophotometric analysis and light irradiance through hot-pressed and hot-pressed-veneered glass ceramics

    Myrna Carvalho Dias, Evandro Piva, Rafael Ratto de Moraes e mais 3Brazilian Dental Journal2008citado por 5 artigos

    This study evaluated the irradiance of curing units through core and veneered hot-pressed ceramics as well as the transmittance of these materials. Discs of 0.7, 1.4 and 2 mm in thickness of Empress (EMP) and Empress Esthetic (EST), and 0.8 (n=5) and 1.1 mm (n=5) thickness of Empress 2 (E2) were obtained. For E2, two…

  20. Light-Curing Units, Photoinitiators System, and Monomers on Physico-Mechanical Properties of Experimental Composite Resins

    Gustavo Furlan da Silva Prezotto, Weverteon Soares de Lima, Rafael Pino Vitti e mais 3Matéria (Rio de Janeiro)2020citado por 1 artigo

    ABSTRACT This study evaluated the physico-mechanical properties of experimental composite resins made with different resin matrix and light-curing units. Experimental composite groups were divided according to monomers (BisGMA + TEGDMA-BT and BisGMA + BisEMA + UDMA + TEGDMA-BBUT) and photoinitiator system…