acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Lens, crystalline”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. The influence of storage method on the transparency of pig crystalline lens

    Cristina Artigas, Adriana Fandiño, Amparo Navea e mais 4Arquivos Brasileiros de Oftalmologia2019

    ABSTRACT Purpose: The porcine eye is frequently used as a research model. This paper analyzes the effect of different storage methods on the transparency of pig crystalline lens. Methods: A spectral transmission curve (from 220 to 780 nm) for the crystalline lens was determined experimentally after storage in…

  2. Oxidative stress of crystalline lens in rat menopausal model

    Semra Acer, Gökhan Pekel, Vural Küçükatay e mais 5Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Purpose: To evaluate lenticular oxidative stress in rat menopausal models. Methods: Forty Wistar female albino rats were included in this study. A total of thirty rats underwent oophorectomy to generate a menopausal model. Ten rats that did not undergo oophorectomy formed the control group (Group 1). From the…

  3. Bilateral ocular deposit of chlorpromazine

    Nayara Teixeira Flügel, Giulia Steuernagel Del Valle e Daniel WasilewskiRevista Brasileira de Oftalmologia2022

    ABSTRACT Chlorpromazine is a medication widely used in psychiatry for the treatment of psychoses, especially schizophrenia. Since 1964, published articles have been correlating this medication with the appearance of ocular alterations. In this paper, we report the case of a 65-year-old patient with ocular effects due…

  4. Intralenticular metal foreign body: case report

    Flavio Mac Cord Medina, Paulo de Tarso Ponte Pierre Filho, Álvaro Pedroso de Carvalho Lupinacci e mais 2Arquivos Brasileiros de Oftalmologia2006

    Intralenticular foreign bodies comprise about 5% to 10% of all intraocular foreign bodies and can result in serious complications. The management depends on some factors like size, location, material type and the risk of infection. We present a patient with an intralenticular metal foreign body in the left eye that…

  5. The influence of size and shape of Nd:YAG capsulotomy on visual acuity and refraction

    Servet Cetinkaya, Yasemin Fatma Cetinkaya, Halil Ibrahim Yener e mais 3Arquivos Brasileiros de Oftalmologia2015citado por 1 artigo

    ABSTRACTPurpose:To evaluate the influence of size and shape of neodymium:yttrium aluminum- Garnet (Nd:YAG) laser capsulotomy on visual acuity and refraction.Methods:We retrospectively evaluated 85 eyes of 67 patients treated with Nd:YAG laser posterior capsulotomy for posterior capsule opacification (PCO). The mean…

  6. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Teresa Ferrer-Blasco, Santiago García-Lázaro, César Albarrán-Diego e mais 2Arquivos Brasileiros de Oftalmologia2012citado por 1 artigo

    PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were…

  7. Refractive lens exchange using SN60T5 AcrySof Toric intraocular lens in stage 2 keratoconus

    Giuliano de Oliveira Freitas, Mário José Carvalho e Joel Edmur BoteonRevista Brasileira de Oftalmologia2011citado por 1 artigo

    This is a case report of a 45-year-old anisometropic woman with stage 2 keratoconus submitted to refractive lens exchange employing SN60T5 AcrySof Toric intraocluar lens on her left eye. Phacoemulsification followed by proper lens implantation was accomplished successfully. On postoperative period, favorable…

  8. Dysfunctional lens syndrome: a prospective review

    Jorge Selem Haddad, Karolinne Maia Rocha, George Oral Waring IV e mais 2Revista Brasileira de Oftalmologia2021

    ABSTRACT The term dysfunctional lens syndrome has gained acceptance in the field and encompasses natural changes due to aging of crystalline lens. The evolution of diagnostic devices has been a key factor in better staging, understanding and characterizing of these degenerative changes. Even with these technological…

  9. Bilateral isolated lens coloboma associated with bicuspid aortic valve

    Mustafa Dogan, Onur Polat, Onder Akcı e mais 2Arquivos Brasileiros de Oftalmologia2015

    ABSTRACT A 27-year-old woman presented with a history of long-standing poor vision in both eyes. Ophthalmologic examination after pupillary dilatation revealed bilateral lens coloboma situated in the inferotemporal quadrant. No associated ocular abnormalities were seen, except amblyopia. A bicuspid aortic valve was…

  10. Coexistence of optic pit and coloboma of iris, lens, and choroid: a case report

    Ramazan Özelce, Vuslat Gürlü, Hande Güçlü e mais 1Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT A 42-year-old woman was admitted to our clinic with a complaint of glare in both eyes. Biomicroscopic examination of both the eyes revealed iris and lens colobomas in the inferior quadrant. Fundus examination of the right eye revealed an oval and gray inferotemporal optic pit and two choroid colobomas in the…

  11. Costs and outcomes of phacoemulsification for cataracts performed by residents

    Roberto Saad Filho, Renata Moreto, Ricardo Okada Nakaghi e mais 3Arquivos Brasileiros de Oftalmologia2020

    ABSTRACT Purpose: To describe costs and outcomes of phacoemulsification for cataracts performed by ophthalmology residents. Methods: We obtained medical records from patients operated on in 2011 by third year residents (R3) using phacoemulsification (n=576). Our expenses estimation included professionals’ and hospital…

  12. Biometric relationships of ocular components in esotropic amblyopia

    Iara Debert, Mariza Polati, Daniela Lima de Jesus e mais 2Arquivos Brasileiros de Oftalmologia2012

    PURPOSE: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients…

  13. New considerations on pupillary block mechanim

    Sebastião Cronemberger, Nassim Calixto, André Oliveirade Andrade e mais 1Arquivos Brasileiros de Oftalmologia2010

    PURPOSE: To study the mechanisms of pupillary block in eyes with occludable angle by ultrasound biomicroscopy. METHODS: Initially, a pilot study of 13 eyes with acute primary angle-closure without medication was executed. Ultrasound biomicroscopy measurements of the angle, posterior chamber depth and iris thickness…

  14. Study of ocular aberrations with age

    Helaine Vinche Zampar Athaide, Mauro Campos e Charles CostaArquivos Brasileiros de Oftalmologia2009citado por 1 artigo

    INTRODUCTION: Aging has various effects on visual system. Vision deteriorate, contrast sensitivity decreases and ocular aberrations apparently make the optical quality worse across the years. PURPOSE: To prospective evaluate ocular aberrations along the ages. METHODS: Three hundred and fifteen patients were examined…

  15. Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software

    Fernanda Pedreira Magalhães, Elaine Fiod Costa, Angelino Júlio Cariello e mais 2Arquivos Brasileiros de Oftalmologia2011citado por 3 artigos

    PURPOSE: To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS) III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. METHODS: One hundred and one eyes from 101 patients with age-related nuclear cataract were…

  16. Phacoemulsification in hard cataracts: the "chop, trip and free" technique

    José Marcos S. GonçalvesArquivos Brasileiros de Oftalmologia2004

    Very hard cataracts continue to be a challenge to phacoemulsification due to the difficulty in breaking the nucleus and also in separating the broken nucleus from the adjacent epinucleus. The present technique is the presentation of a surgical maneuver which uses the Nagahara chopper and the phaco tip to divide the…

  17. Anterior capsule staining using 0.025% trypan blue in cataracts without red reflex

    Eduardo Ferrari Marback, Lincoln Lemes de Freitas, Fernanda Pelegrino Fernandes e mais 2Arquivos Brasileiros de Oftalmologia2001citado por 3 artigos

    Purpose: To describe the use of anterior capsule staining in cataracts without red reflex using a 0.025% trypan blue solution. Methods: Six eyes of 6 patients with cataracts without red reflex were submitted to phacoemulsification using a direct injection of 0.2 to 0.5 ml of 0.025% trypan blue in the anterior chamber…

  18. Oxidative Modifications in Crystallin Proteins and Lens Epithelial Cells Associated with Photosensitized Reactions Mediated by the Major Chromophore Arising from Glucose Degradation

    Francisco Vargas, María Inés Becker, Bertrand Friguet e mais 2Journal of the Brazilian Chemical Society2016

    Deleterious effect mediated by glucose degradation, as a parallel pathway to Maillard reaction, was analyzed in terms of the feasibility of inducing photo-crosslinking in isolated bovine crystalline proteins when exposed to ultraviolet A (UVA)-visible light. These experiments showed evidence supporting the generation…