Adaptive Control Based on Virtual Plant Applied to Synchronous Buck Converter using LCL Filter for Charging Lithium-Ion Batteries
Vinícius D. Rodrigues, Maicon de Miranda, Wagner B. da Silveira e mais 3Eletrônica de Potência2026
ABSTRACT This paper introduces a virtual plant method as the main contribution, applied independently to two discrete-time adaptive control strategies for a synchronous buck converter used in battery charging: an Adaptive PI Controller (API) and a Model Reference Adaptive Controller (MRAC). The system employs an LCL…