Method validation and stability study of quercetin in topical emulsions
Rúbia Casagrande, Marcela M. Baracat, Sandra R. Georgetti e mais 5Química Nova2009
This study validated a high performance liquid chromatography (HPLC) method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation…