  1. Evaluation of a PVC sensing phase for determination of chlorinated hydrocarbons in water by mid-infrared spectroscopy

    Andréa Monteiro S. Silva, Eduardo de Araujo Viana, Maria Fernanda Pimentel e mais 2Journal of the Brazilian Chemical Society2011

    In this work, mid-infrared spectroscopy has been employed to investigate the effect of amount (25 or 40%) and type of plasticiser (di-2-ethylhexyl sebacate (DOS), di-2-ethylhexyl phthalate (DOP) and 2-nitrophenyl octyl ether (NPOE)) on the analytical response of a poly(vinylchloride) (PVC) sensing phase for the…

  2. Sensores ópticos com detecção no infravermelho próximo e médio

    Kássio M. G. Lima, Ivo M. Raimundo Jr., Andréa Monteiro S. Silva e mais 1Química Nova2009

    Optical chemical sensors with detection in the near and mid infrared region are reviewed. Fundamental concepts of infrared spectroscopy and optical chemical sensors are briefly described, before presenting some aspects on optical chemical sensors, such as synthesis of NIR and IR reagents, preparation of new materials…

  3. Construção de uma cela de fluxo de longo caminho óptico para medidas espectrofotométricas

    Wanessa Roberto Melchert, Fábio R. P. Rocha, Ivo M. Raimundo Jr. e mais 1Química Nova2008

    A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL) comparable to that of a 1-cm conventional cell (80 µL). Despite the increase in optical path, the…

  4. Uso de membranas de Nafion para a construção de sensores ópticos para medidas de pH

    Silvia Cristina Lopes Pinheiro e Ivo M. Raimundo JrQuímica Nova2005

    The behaviour of Nafion® polymeric membranes containing acid-base dyes, bromothymol blue (BB) and methyl violet (MV), were studied aiming at constructing an optical sensor for pH measurement. BB revealed to be inadequate for developing sensing phases due to the electrostatic repulsion between negative groups of their…

  5. Gran method for end point anticipation in monosegmented flow titration

    Emerson V Aquino, Celio Pasquini, Jarbas J. R Rohwedder e mais 3Journal of the Brazilian Chemical Society2004

    An automatic potentiometric monosegmented flow titration procedure based on Gran linearisation approach has been developed. The controlling program can estimate the end point of the titration after the addition of three or four aliquots of titrant. Alternatively, the end point can be determined by the second…

  6. Monosegemented flow potentiometric titration for the determination of chloride in milk and wine

    Jonas A. Vieira, Ivo M. Raimundo Jr., Boaventura F. Reis e mais 2Journal of the Brazilian Chemical Society2003

    An automated flow potentiometric titration procedure for the determination of chloride in milk and wine exploiting the monosegmented flow approach is described. The flow network was designed based on a six-way solenoid valve, controlled by a microcomputer running software written in VisualBasic 3.0, allowing selection…