acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Infusion pumps”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Implementing barcode medication administration and smart infusion pumps is just the beginning of the safety journey to prevent administration errors

    Christina Michalek e Stacy L CarsonFarmacia Hospitalaria2020citado por 1 artigo

    Abstract Introduction: Healthcare-related technology has been widely accepted as a key patient safety solution to reduce adverse drug events by decreasing the risk of human error. The introduction of technology can enhance safety and support workflow; however, it does not eliminate all error types and may create new…

  2. Hemolysis risk after packed red blood cells transfusion with infusion pumps

    Ana Maria Miranda Martins Wilson, Maria Angélica Sorgini Peterlini e Mavilde da Luz Gonçalves PedreiraRevista Latino-Americana de Enfermagem2018citado por 2 artigos

    ABSTRACT Objective: To evaluate the hemolysis biomarkers of packed red blood cells transfused by two different linear peristaltic infusion pumps at two infusion rates. Method: An experimental and randomized study was designed simulating the clinical practice of transfusion. Two linear peristaltic infusion pumps from…

  3. Usability of volumetric infusion pumps in pediatric intensive care

    Elizandra Cassia da Silva Oliveira, Roberto Carlos Lyra da Silva, Gustavo Aires de Arruda e mais 1Revista da Escola de Enfermagem da USP2021

    ABSTRACT Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to…

  4. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Ana Maria Miranda Martins Wilson, Maria Angélica Sorgini Peterlini e Mavilde da Luz Gonçalves PedreiraRevista Latino-Americana de Enfermagem2016citado por 1 artigo

    ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific…

  5. Start-up delay in syringe infusion pumps with different rates and priming techniques of intravenoust sets

    Natalie Marino Vieira, Maria Paula de Oliveira Pires, Gabriela Beltran Crespo e mais 3Revista Gaúcha de Enfermagem2022

    ABSTRACT Objective: To investigate infusion pumps start-up delay according to different brands of infusion pumps, flow rates and intravenous sets priming techniques. Method: The experimental study simulated clinical practice under controlled conditions, using a 50 mL syringe with NaCl 0.9% solution, two syringe…

  6. Cost-effectiveness of infusion pumps to reduce errors in a Pediatric ICU

    Roberto Carlos Lyra da Silva, Thiago QuinellatoLouro, Antônio Augusto de Freitas Peregrino e mais 3Revista Brasileira de Enfermagem2019

    ABSTRACT Objective: To analyze cost-effectiveness and to calculate incremental cost-effectiveness ratio of the use of infusion pumps with drug library to reduce errors in intravenous drug administration in pediatric and neonatal patients in Intensive Care Units. Methods: Mathematical modeling for economic analysis of…

  7. Cost-effectiveness of infusion pumps to reduce errors in a Pediatric ICU

    Roberto Carlos Lyra da Silva, Thiago QuinellatoLouro, Antônio Augusto de Freitas Peregrino e mais 3Revista Brasileira de Enfermagem2019

    ABSTRACT Objective: To analyze cost-effectiveness and to calculate incremental cost-effectiveness ratio of the use of infusion pumps with drug library to reduce errors in intravenous drug administration in pediatric and neonatal patients in Intensive Care Units. Methods: Mathematical modeling for economic analysis of…

  8. WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY

    Ricardo Guilherme VIEBIG, Janaina Tomiye Yamakata FRANCO, Sergio Viebig ARAUJO e mais 1Arquivos de Gastroenterologia2018

    ABSTRACT BACKGROUND: High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. OBJECTIVE: To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry…

  9. Multiple basal infusion rates in open-loop insulin delivery systems: is there a metabolic benefit?

    Juliana Marques Sá, Sara de Campos Lopes, Maria Joana Santos e mais 2Archives of Endocrinology and Metabolism2024

    ABSTRACT Objective: To evaluate glycemic control according to the number of daily basal rates (BRs) in type 1 diabetes patients using continuous subcutaneous insulin infusion (CSII). Subjects and methods: Cross-sectional study of patients treated with an open-loop CSII for at least 6 months and using a flash glucose…

  10. Use of technologies in intravenous therapy: contributions to a safer practice

    Ana Paula Amorim Moreira, Cristina Lavoyer Escudeiro, Bárbara Pompeu Christovam e mais 3Revista Brasileira de Enfermagem2017citado por 3 artigos

    ABSTRACT Objectives: To identify what are the difficulties of the nursing staff in the management of technologies during intravenous therapy (IVT) and discuss the difficulties identified under the perspective of patient's safety. Method: Descriptive study of qualitative approach with data collected by semi-structured…

  11. Handling errors in conventional and smart pump infusions: A systematic review with meta-analysis

    Ana Paula Amorim Moreira, Márglory Fraga de Carvalho, Roberto Carlos Lyra da Silva e mais 3Revista da Escola de Enfermagem da USP2020

    Abstract Objective: To identify the scientific evidence on the frequency of handling errors of conventional and smart pump infusions in intravenous insulin therapy in intensive care units. Method: A systematic review with meta-analysis conducted in the Virtual Health Library, MEDLINE via PubMed, Scopus and Web of…