acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Hydrochloric acid”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. KINETIC STUDY OF 1020 CARBON STEEL CORROSION IN HYDROCHLORIC AND NITRIC ACID MEDIA

    Fernando C. Oliveira, Almir Silva Neto, Lucas Brites Fares e mais 2Química Nova2025

    This study investigates the corrosion mechanism of 1020 carbon steel in strong acid solutions, relevant for industrial applications, using simple and effective laboratory methods. Direct (weight loss) and indirect (pH, ionic conductivity, open circuit potential and polarization curves) negotiations were performed to…

  2. Schiff Bases of Triethylenetetramine as Corrosion Inhibitors of Zinc in Hydrochloric Acid

    M.D. Shah, A.S. Patel, G.V. Mudaliar e mais 1Portugaliae Electrochimica Acta2011

    The performance of triethylenetetramine-tribenzylidene (TTTB) and triethylenetetramine-trisalicylidene (TTTS) as corrosion inhibitors for zinc in hydrochloric acid is investigated. At lower concentrations, both inhibitors accelerate the attack but inhibit corrosion at higher concentrations, e.g., 96-100% with 1.0%…

  3. Corrosion Resistance of Mo3Si with Niobium Additions in Hydrochloric Acid

    C. Huicochea, I. Rosales, I.E. Castañeda e mais 1Portugaliae Electrochimica Acta2007

    In the present work, the electrochemical behavior of molybdenum-silica-niobium alloy produced by arc cast technique is presented, keeping silica constant (at 24 wt %), using different niobium concentrations (5, 10, 15 & 20 wt %) as alloying elements. These samples were immersed in an electrochemical solution of 10 %…

  4. Modeling of Corrosion Kinetics of Mild Steel in Hydrochloric Acid in the Presence and Absence of a Drug Inhibitor

    Salah H. AljbourPortugaliae Electrochimica Acta2016citado por 1 artigo

    Cefixime was investigated as a corrosion inhibitor for mild steel in an hydrochloric acid solution. The results revealed that the order of reaction is 0.427, with activation energy found to be 41.7 kJ/mol. Cefixime was effective in increasing the inhibition efficiency for all inhibition concentrations. The corrosion…

  5. Hydrochloric Acid Corrosion Inhibition of Zn-Al-Cu Alloy by Methyl-Substituted Piperidines

    S.S. MahmoudPortugaliae Electrochimica Acta2008

    The corrosion behavior of Zn-Al-Cu alloy was investigated in HCl solution in absence and in presence of different concentrations of inhibitors. The techniques of measurements were: weight loss, linear polarization and galvanic static polarization. It was found that the corrosion rate of this alloy was higher than that…

  6. Tailored Dealloying Products of Cu-based Metallic Glasses in Hydrochloric Acid Solutions

    Zhifeng Wang, Lijuan Wang, Chunling Qin e mais 3Materials Research2014

    Free dealloying of Cu-Hf-Al metallic glasses in HCl electrolytes are studied in this paper. The results show that the electrolyte concentration and dealloying time strongly influence the type of dealloying products. A superficial dealloying happens in diluted HCl electrolytes while a complete dealloying occurs in…

  7. Corrosion Inhibition of 304 SS in Hydrochloric Acid Solution by N - Furfuryl N'- Phenyl Thiourea

    R. Herle, P. Shetty, S.D. Shetty e mais 1Portugaliae Electrochimica Acta2011

    The inhibition of corrosion of 304 SS in 2 N HCl solutions by N - furfuryl - N' phenyl thiourea (FPTU) has been investigated using potentiodynamic polarization techniques. The results obtained reveal that FPTU performs excellently as anodic inhibitor (IE> 93%) for 304 SS in HCl solution. The inhibitor functions…

  8. Effect of beverages on bovine dental enamel subjected to erosive challenge with hydrochloric acid

    Dinah Ribeiro Amoras, Silmara Aparecida Milori Corona, Antonio Luiz Rodrigues Jr e mais 1Brazilian Dental Journal2012citado por 1 artigo

    This study evaluated by an in vitro model the effect of beverages on dental enamel previously subjected to erosive challenge with hydrochloric acid. The factor under study was the type of beverage, in five levels: Sprite® Zero Low-calorie Soda Lime (positive control), Parmalat® ultra high temperature (UHT) milk, Ades®…

  9. Experimental carcinogenesis on the oropharyngeal mucosa of rats with hydrochloric acid, sodium nitrate and pepsin

    André Del Negro, Marina Raquel Araújo, Alfio José Tincani e mais 3Acta Cirúrgica Brasileira2008citado por 1 artigo

    PURPOSE: To investigate the carcinogenic action of hydrochloric acid, pepsin and sodium nitrate on the oropharyngeal mucosa of rats, simulating the reflux of gastric contents. METHODS: Eighty-two Wistar rats were divided in seven groups and submitted to 2 or 3 weekly applications of hydrochloric acid, pepsin and…

  10. Effect of foods and drinks on primary tooth enamel after erosive challenge with hydrochloric acid

    Késsia Suênia Fidelis de MESQUITA-GUIMARÃES, Camila SCATENA, Maria Cristina BORSATTO e mais 2Brazilian Oral Research2015

    The aim of this study was to evaluate the effect of industrialised foods and drinks on primary tooth enamel previously eroded with hydrochloric acid (HCl). The crowns of one hundred two specimens were subjected to an erosive challenge with HCl and randomly divided into six groups (n = 17): Chocolate Milk (Toddynho® -…

  11. Fennel (Foeniculum Vulgare) Essential Oil as Green Corrosion Inhibitor of Carbon Steel in Hydrochloric Acid Solution

    N. Lahhit, A. Bouyanzer, J.-M. Desjobert e mais 6Portugaliae Electrochimica Acta2011citado por 2 artigos

    Essential oil from fennel (Foeniculum vulgare) (FM) was tested as corrosion inhibitor of carbon steel in 1 M HCl using electrochemical impedance spectroscopy (EIS), Tafel polarisation methods and weight loss measurements. The results show that the increase of the charge-transfer resistance (Rct) with the oil…

  12. Surface Roughness of Composite Resins Subjected to Hydrochloric Acid

    Ana Carolina Cabral Roque, Lauren Oliveira Lima Bohner, Ana Paula Terossi de Godoi e mais 3Brazilian Dental Journal2015

    The purpose of this study was to determine the influence of hydrochloric acid on surface roughness of composite resins subjected to brushing. Sixty samples measuring 2 mm thick x 6 mm diameter were prepared and used as experimental units. The study presented a 3x2 factorial design, in which the factors were composite…

  13. Corrosion Inhibition Efficiency of 3-Hydroxy-2-Methylquinazoline-4-one on Mild Steel in 1 M H2 SO4 and 1 M HCl Acid at Different Temperatures

    W.A. Siddiqi e V. M. ChaubeyPortugaliae Electrochimica Acta2008

    The influence of 3-hydroxy-2-methylquinazoline -4-one on the corrosion inhibition of mild steel in 1 M HCl and 1 M H2SO4 has been studied using weight loss, and galvanostatic polarization studies. Result obtained reveals that this organic compound is a very good inhibitor and its inhibition efficiency increases with…

  14. Etching on the edge: enamel loss under repeated and active HCl applications as a resin infiltration pretreatment

    Maria Paula Novaes Camargo MANNA, Talita Portela PEREIRA, Bruna de Oliveira IATAROLA e mais 4Journal of Applied Oral Science2025

    Abstract Considering that a single passive application of hydrochloric acid (HCl) as a resin infiltration pretreatment can remove between 20 and 45 µm of enamel and cause etching that extends up to 2 mm beyond the white spot lesions (WSLs), it is plausible that its repeated and active applications could result in a…

  15. Characterization of Polyamide 66 membranes prepared by phase inversion using formic acid and hydrochloric acid such as solvents

    Patrícia Poletto, Jocelei Duarte, Mônica Beatriz Thürmer e mais 2Materials Research2011citado por 4 artigos

    The membranes properties prepared from water/formic acid (FA)/ polyamide 66 (PA66) and water/hydrochloric acid (HCl)/polyamide 66 (PA 66) systems has been studied. The different solvents interact distinctly with the polymer, affecting the membrane morphology. The asymmetric structure of the membranes showed a dense…

  16. Effect of Conditioning Protocols and Ultrasonic Application of an Infiltrant Resin in White Spot Lesions

    Edgar Alexander López López, John Alexis Dominguez, Giovana Mongruel Gomes e mais 4Brazilian Dental Journal2019

    Abstract The aim of this study was to evaluate different conditioning protocols and sonic/ultrasonic application of an infiltrant resin (IR) in artificial white spot lesions (AWSL). the V/L surfaces of 48 molars were induced to an AWSL and divided in 6 groups, according to the conditioning protocols and application…

  17. Thermal decomposition of ethylenediaminetetraacetic acid in the presence of 1,2-phenylenediamine and hydrochloric acid

    Jingwen Chen, Jinhao Gao e Xiaoyong WangJournal of the Brazilian Chemical Society2006

    Based on the reaction products of ethylenediaminetetraacetic acid (EDTA) with 1,2-phenylenediamine (o-PDA), a novel thermal decomposition pathway of EDTA is proposed. The strong acidic medium and the presence of o-PDA facilitate the decomposition of EDTA as evidenced by the relatively lower reaction temperature. In…

  18. Pyrazole Derivatives as Corrosion Inhibitors for Steel in Hydrochloric Acid

    L. Herrag, A. Chetouani, S. Elkadiri e mais 2Portugaliae Electrochimica Acta2008

    The effect of 1-{[benzyl-(2-cyano-ethyl)-amino]-methyl}-5-methyl-1H-pyrazole-3-carboxylic acid methyl ester (P1) and 1-{[benzyl-(2-cyano-ethyl)-amino]-methyl}-5-methyl-1H-pyrazole-3-carboxylic acid ethyl ester (P2) was evaluated as corrosion inhibitors of steel in molar hydrochloric using weight loss measurements and…

  19. Thymus Sahraouian Essential Oil as Corrosion Eco-friendly Inhibitor for Mild Steel in a Molar Hydrochloric Acid Solution

    Z. Bensouda, M. Driouch, R. A. Belakhmima e mais 3Portugaliae Electrochimica Acta2018

    Thymus Sahraouian essential oil (TSEO), as a new corrosion eco-friendly inhibitor, has been used to protect mild steel in 1 M HCl. Weight loss, three potentiodynamic polarization methods (Tafel, Stern and Stern-Geary), and electrochemical impedance spectroscopy measurements were undertaken to evaluate corrosion…