acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Heart Valve Prosthesis Implantation”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Early Clinical Results of Perceval Sutureless Aortic Valve in 139 Patients: Freeman Experience

    Syed Saleem Mujtaba, Simon Ledingham, Asif Raza Shah e mais 3Brazilian Journal of Cardiovascular Surgery2018

    Abstract Objective: The aim of this retrospective study is to evaluate the safety and performance of the Perceval sutureless valve in patients undergoing aortic valve replacement. We report the 30-day clinical outcomes of 139 patients. Methods: From January 2014 to December 2016, 139 patients underwent sutureless…

  2. Combined Mitral and Aortic Valvar Bioprosthesis Transcatheter Transapical Implant: First Description in Brazil

    Roney Orismar Sampaio, Milena Ribeiro Paixão, Thais Taveira Miranda e mais 3Arquivos Brasileiros de Cardiologia2017

    Introducao Desde os primordios da cirurgia cardiaca, as valvas, quando nao era possivel a reparacao, eram substituidas por proteses utilizando a circulacao extracorporea. Os bons resultados destes procedimentos sao bem conhecidos. Nos ultimos anos, alternativas minimamente invasivas tem sido desenvolvidas com o…

  3. Aortic Valve Reconstruction with Ozaki Technique

    Gabriella Ricciardi, Raoul Biondi, Gabriele Tamagnini e mais 1Brazilian Journal of Cardiovascular Surgery2022citado por 1 artigo

    Abstract Modern bioprostheses offer a complete and definitive solution to elderly patients who need aortic valve surgery. Nonetheless, the scenario is more demanding when dealing with younger and less fragile patients. In this setting, any prosthetic aortic valve replacement can provide only a suboptimal solution and…

  4. Thrombocytopenia After Transcatheter Valve-in-Valve Implantation: Prognostic Marker or Mere Finding?

    Renato C. de Souza, Leonardo Paim, Guilherme Viotto e mais 8Brazilian Journal of Cardiovascular Surgery2018citado por 1 artigo

    Abstract Objective: To analyze the behavior of platelets after transcatheter valve-in-valve implantation for the treatment of degenerated bioprosthesis and how they correlate with adverse events upon follow-up. Methods: Retrospective analysis of 28 patients who received a valve-in-valve implant, 5 in aortic, 18 in…

  5. Aortic Valve Replacement with a Conventional Stented Bioprosthesis versus Sutureless Bioprosthesis: a Study of 763 Patients

    Syed Saleem Mujtaba, Simon M. Ledingham, Asif Raza Shah e mais 3Brazilian Journal of Cardiovascular Surgery2018citado por 1 artigo

    Abstract Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. Methods: From January 2011 to December 2016, 763 patients underwent aortic…

  6. Comparison of Biological and Mechanical Prostheses for Heart Valve Surgery: A Systematic Review of Randomized Controlled Trials

    Alberto Takeshi Kiyose, Erica Aranha Suzumura, Lígia Laranjeira e mais 7Arquivos Brasileiros de Cardiologia2019citado por 1 artigo

    Abstract Background: The choice of a mechanical (MP) or biological prosthesis (BP) for patients with valvular heart disease undergoing replacement is still not a consensus. Objective: We aimed to determine the clinical outcomes of MP or BP placement in those patients. Methods: We conducted a systematic review and…

  7. Percutaneous Treatment of Mitral Paraprosthetic Regurgitation: an Alternative to Surgery

    Roney Orismar Sampaio, Alessandra Gomes de Oliveira, George Barreto Miranda e mais 3Arquivos Brasileiros de Cardiologia2015

    Paraprosthetic regurgitation occurs in approximately 7%–17% of patients undergoing mitral valve replacement and 2%–10% of patients undergoing aortic valve replacement1,2. Typically, this regurgitation is discrete and does imply major clinical complications; however, when it is moderate or severe, the consequences can…

  8. Quadruple Valve Replacement for Carcinoid Heart Disease

    Syed Saleem Mujtaba e Stephen ClarkBrazilian Journal of Cardiovascular Surgery2018

    Abstract Introduction: Carcinoid heart disease most frequently involves the tricuspid or, more rarely, the pulmonary valve and presents with right heart failure as 5-HT is metabolized by the lung. Left-sided valve involvement is quite rare. We describe our experience of 3 patients presenting with heart failure…

  9. The transvalvar gradient after the aortic porcine stented valve replacement can be predicted?

    Eduardo Augusto Victor Rocha, Renato Rocha Rabello, Sérgio Caporali de Oliveira e mais 3Brazilian Journal of Cardiovascular Surgery2003

    OBJECTIVE: This work aimed at establishing scientific criteria using the valve size mismatch to predict the transvalvar gradient resultant of aortic valve replacement. METHOD: Thirty-one consecutive patients who survived aortic valve replacement surgeries using Labcor porcine stented prosthesis, in the period from…

  10. The Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation

    Yosuke Miyazaki, Rodrigo Modolo, Mohammad Abdelghani e mais 14Arquivos Brasileiros de Cardiologia2018

    Abstract Background: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is…

  11. Mortality Predictors in the Surgical Treatment of Active Infective Endocarditis

    Jenny Lourdes Rivas de Oliveira, Magaly Arrais dos Santos, Renato Tambellini Arnoni e mais 5Brazilian Journal of Cardiovascular Surgery2018citado por 3 artigos

    Abstract Introduction: Active infective endocarditis is associated with high morbidity and mortality. Surgery is indicated in high-risk conditions, and the main determinants of mortality in surgical treatment should be evaluated. Objective: To identify mortality predictors in the surgical treatment of active infective…

  12. Transcatheter Aortic Valve Replacement: The Experience of One Brazilian Health Care Center

    Fabiula Schwartz Azevedo, Marcelo Goulart Correa, Débora Holanda Gonçalves Paula e mais 9Brazilian Journal of Cardiovascular Surgery2018citado por 1 artigo

    Abstract Objective: Transcatheter aortic valve replacement has been an alternative to invasive treatment for symptomatic severe aortic stenosis in high risk patients. The primary endpoint was 30-day and 1-year mortality from any cause. Secondary endpoints were to compare the clinical and echocardiographic variation…

  13. Mitral valve replacement with the preservation of the entire valve apparatus

    Ahmed A. AlsaddiqueBrazilian Journal of Cardiovascular Surgery2007citado por 2 artigos

    OBJECTIVE: The papillary muscles and the chordae tendineae of both mitral leaflets contribute to the preservation of the left ventricular function. Most surgeons, however, routinely excise the anterior mitral leaflet. METHODS: In a group of nine patients, six of them underwent mitral valve replacement alone and three…

  14. Transcatheter Valve-in-Valve Repositioning of CoreValve® Evolut™ Rin Aortic Prosthesis

    Ana Isabel Azevedo, Ricardo Ladeiras-Lopes, Alberto Rodrigues e mais 2Arquivos Brasileiros de Cardiologia2016

    A 41-year-old man with history of surgical replacement of the aortic valve with a 21mm-Mitroflow bioprosthesis (1A), presented with functional class IV heart failure. Transesophageal echocardiography confirmed severe bioprosthesis obstruction (1B). We implanted a 23mm-CoreValve® Evolut™ R (Medtronic, Minneapolis, USA)…

  15. The cost of transcatheter aortic valve implantation according to different access routes

    Eliana Bittar e Valéria CastilhoRevista da Escola de Enfermagem da USP2017citado por 1 artigo

    Abstract OBJECTIVE Identifying the average direct cost of TAVI (Transcatheter Aortic Valve Implantation) for the different access routes. METHOD This is a research with a quantitative, exploratory and descriptive approach carried out in a government teaching hospital in the state of São Paulo. RESULTS The average…

  16. Sutureless Aortic Prosthesis Implantation: the First Brazilian Experience with Perceval Device

    Ana Paula Tagliari, Leandro de Moura, Luiz Henrique Dussin e mais 1Brazilian Journal of Cardiovascular Surgery2016citado por 1 artigo

    Abstract This is a report of the first Brazilian experience with the Perceval sutureless aortic prosthesis in two patients with severe aortic stenosis. Transesophageal echocardiography was used during the procedure. The aortotomy was performed 1 cm above the sinotubular junction, followed by leaflets removal and…

  17. Progression and Prognosis of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation

    Rafael Alexandre Meneguz-Moreno, Antônio de Castro-Filho, Auristela Isabel de Oliveira Ramos e mais 7Arquivos Brasileiros de Cardiologia2017

    Abstract Background: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) remains uncertain. Objective: To evaluate the impact of PVR on mortality and hospital readmission one year after TAVI. Methods: Between January 2009 and June 2015, a total of 251 patients…

  18. Valvular Heart Team

    Max GrinbergArquivos Brasileiros de Cardiologia2014

    An idealist is a person who helps other people to be prosperous."Henry Ford (1863 -1947

  19. Multiple Anterior Mitral Valve Perforation After Deep Transfemoral Aortic Valve Implantation

    Hakan Fotbolcu e Ramazan ÖzdemirBrazilian Journal of Cardiovascular Surgery2022

    Abstract Transcatheter aortic valve implantation (TAVI) is an alternative for high-risk aortic valve replacement. There are limited data related to the late complications of TAVI. Deep aortic prosthetic valve implantation can cause direct erosive perforation of anterior mitral leaflet or erosive endothelial lesion…

  20. Mitral Valve-In-Valve: Defining the Indication Limits by in vitro Hydrodynamic Tests in a Brazilian Transcatheter Prosthesis

    Thiago Vila Nova, Caio Cardoso, Ademir Braz e mais 2Brazilian Journal of Cardiovascular Surgery2021

    Abstract Introduction: Reoperations in cardiac surgery represent a clinical challenge, particularly because of the higher rate of perioperative morbidity and mortality. Mitral valve reoperation owing to bioprosthesis dysfunction, transcatheter treatment with a prosthesis implantation over the prosthesis has emerged as…