acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Halogen light”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Abrasion resistance of composites polymerized by light-emitting diodes (LED) and halogen light-curing units

    Janisse Martinelli, Fernanda de Carvalho Panzeri Pires-de-Souza, Luciana Assirati Casemiro e mais 2Brazilian Dental Journal2006citado por 2 artigos

    This study compared the abrasion resistance of direct composite resins cured by light-emitting diodes (LED) and halogen light-curing units. Twenty specimens (12 mm in diameter; 1.0 mm thick) of each composite resin [TPH (Dentsply); Definite (Degussa); Charisma (Heraus Kulzer)] were prepared using a…

  2. Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units

    Bianca Micali e Roberta Tarkany BastingBrazilian Oral Research2004citado por 7 artigos

    The clinical performance of composite resins is greatly influenced by the quality of the light-curing unit used. The aim of this study was to compare the efficiency of a commercial light-emitting diode (LED) with that of a halogen-based light-curing unit by means of dye penetration of a micro hybrid composite resin…

  3. Color stability of composites subjected to accelerated aging after curing using either a halogen or a light emitting diode source

    Fernanda de Carvalho Panzeri Pires-de-Souza, Lucas da Fonseca Roberti Garcia, Hisham Mohamad Hamida e mais 1Brazilian Dental Journal2007citado por 5 artigos

    The purpose of this study was to evaluate, in vitro, the color stability of three composite resins of two different shades (A3 and C3) cured with either a quartz tungsten halogen (QTH) or a light emitting diode (LED) source. Forty specimens (20 x 2 mm) were prepared for each composite (Tetric Ceram®, Heliomolar® and…

  4. Shear bond strength of orthodontic brackets bonded using halogen light and light-emitting diode at different debond times

    Rebeca Di Nicoló, Maria Amelia Maximo de Araujo, Levy Anderson César Alves e mais 2Brazilian Oral Research2010

    The aim of this in vitro study was to compare the photoactivation effects of QTH (Quartz-Tungsten-Halogen) and LED (Light-Emitting Diode) on the SBS (Shear Bond Strength) of orthodontic brackets at different debond times. Seventy-two bovine lower incisors were randomly divided into two groups according to the…

  5. Degree of conversion of adhesive systems light-cured by LED and halogen light

    Cesar Augusto Galvão Arrais, Fenelon Martinho Pontes, Luis Presley Serejo dos Santos e mais 2Brazilian Dental Journal2007citado por 4 artigos

    This study evaluated the effect of blue light emitting diode (LED) and quartz tungsten halogen (QTH) on the degree of conversion (DC) of an etch-and-rinse Single Bond adhesive system (SB) and a mixture composed of primer solution and resin bond from Clearfil SE Bond self-etching adhesive system (CB) using Fourier…

  6. LED and Halogen Light Transmission through a CAD/CAM Lithium Disilicate Glass-Ceramic

    Carolina Nemesio de Barros Pereira, Cláudia Silami de Magalhães, Bruno Daleprane e mais 4Brazilian Dental Journal2015citado por 1 artigo

    The effect of thickness, shade and translucency of CAD/CAM lithium disilicate glass-ceramic on light transmission of light-emitting diode (LED) and quartz-tungsten-halogen units (QTH) were evaluated. Ceramic IPS e.max CAD shades A1, A2, A3, A3.5, high (HT) and low (LT) translucency were cut (1, 2, 3, 4 and 5 mm)…

  7. Effect of light-curing units and activation mode on polymerization shrinkage and shrinkage stress of composite resins

    Lawrence Gonzaga Lopes, Eduardo Batista Franco, José Carlos Pereira e mais 1Journal of Applied Oral Science2008citado por 6 artigos

    The aim of this study was to evaluate the polymerization shrinkage and shrinkage stress of composites polymerized with a LED and a quartz tungsten halogen (QTH) light sources. The LED was used in a conventional mode (CM) and the QTH was used in both conventional and pulse-delay modes (PD). The composite resins used…

  8. Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED

    Cecy Martins Silva e Katia Regina Hostilio Cervantes DiasBrazilian Dental Journal2009citado por 1 artigo

    This study compared the compressive strength of a composite resin and compomer photoactivated with a conventional quartz-tungsten halogen-light (XL 3000, 3M/SPE) and a blue light-emitting diode (LED) (SmartLite PS; Dentsply/De Trey). Forty disc-shaped specimens were prepared using a split polytetrafluoroethylene…

  9. Analysis of the microtensile bond strength to enamel of two adhesive systems polymerized by halogen light or LED

    Ana Paula Morales Cobra Carvalho e Míriam Lacalle TurbinoBrazilian Oral Research2005

    With the development of composite resin polymerization techniques, LEDs were introduced to the market place. Based on the studied literature, the aim of this study was to evaluate, through microtensile testing, the bond strength to enamel of a composite resin associated to a conventional (multi-bottle) adhesive system…

  10. Polymerization shrinkage stress of composites photoactivated by different light sources

    Fernanda de Carvalho Panzeri Pires de Souza, Brahim Drubi Filho, Luciana Assirati Casemiro e mais 2Brazilian Dental Journal2009citado por 4 artigos

    The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum…

  11. Effect of light-curing units in shear bond strength of metallic brackets: an in vitro study

    Luciana Borges Retamoso, Niége Michelle Lazzari Onofre, Luciane Hann e mais 1Journal of Applied Oral Science2010

    OBJECTIVES: To determine the influence of the light curing units on the shear bond strength of orthodontic brackets. MATERIAL AND METHODS: Seventy-two premolars were divided into six groups (n=12): Group I: brackets bonded with Transbond and polymerization with halogen light; Group II: Transbond and LED; Group III…

  12. Bond strength and marginal microleakage in restorations photopolymerized with LED and halogen light associated with three application modes of a universal adhesive system: in vitro study

    Felipe de Brum RICARDI, Mauro Carlos Agner BUSATO, Priscilla do Monte Ribeiro BUSATO e mais 3RGO - Revista Gaúcha de Odontologia2019

    ABSTRACT Objective: This study aimed to assess the bond strength and marginal microleakage in composite resin restorations, using the Single Bond Universal adhesive system associated with Ultralux (halogen) and Bluephase (LED) light curing units. Methods: For bond strength, 80 healthy human third molars were divided…

  13. Halogen light versus LED for bracket bonding: shear bond strength

    Paulo Eduardo Guedes Carvalho, Valdemir Muzulon dos Santos, Hassan Isber e mais 1Dental Press Journal of Orthodontics2013citado por 1 artigo

    INTRODUCTION: LED light-curing devices seek to provide a cold light activator which allows protocols of material polymerization with shorter duration. OBJECTIVE: The present study aimed to evaluate the shear bond strength of bracket bonding using three types of light-curing devices: One with halogen light (Optilight…

  14. Polymerization of a dual-cured cement through ceramic: LED curing light vs halogen lamp

    Lawrence Gonzaga Lopes, Eduardo Batista Franco, Abrão Name Neto e mais 4Journal of Applied Oral Science2004citado por 1 artigo

    The aim of this study was to investigate the influence of light source, LED unit and halogen lamp (HL), on the effectiveness of Enforce dual-cured cement cured under a ceramic disc. Three exposure times (60, 80 and 120 s) were also evaluated. Two experimental groups, in which the polymerization of the dual-cured…

  15. Influence of plasma arc and quartz-tungsten-halogen curing lights on the polymerization of orthodontic composite resin

    Telmo Bandeira Berthold, Guilherme Cerveira, Roger Berthold e mais 3Revista Odonto Ciência2011

    PURPOSE: To analyze, in vitro, the influence of a quartz-tungsten-halogen (QTH) and a plasma arc (PAC) on the degree of conversion and hardness of a composite resin, as well as the heat generated by the units. METHODS: Transbond XT disks were prepared and light-cured for 10, 20 and 30 seconds with a QTH (Curing Light…

  16. Effect of the Incorporation of EDB Co-initiator in the Resin in Halogen and LED Light

    Aline Cristina da Silva Tanaka, Giovanny Carvalho dos Santos, Rafael Turra Alarcon e mais 2Materials Research2021

    Abstract This paper evaluated the influence of the incorporation of the coinitiator Ethyl 4-(dimethylamino) benzoate (EDB) in Filtek Z250 XT resin in the reduction of the polymerization time and its behavior in halogen light and LED (Light Emitting Diode) light. The samples were subjected to thermal and spectroscopic…

  17. Microhardness of resin-based materials polymerized with LED and halogen curing units

    Daniela Francisca Gigo Cefaly, Giovano Augusto de Oliveira Ferrarezi, Celiane Mary Carneiro Tapety e mais 2Brazilian Dental Journal2005citado por 6 artigos

    The purpose of this study was to evaluate the microhardness of resin-based materials polymerized with a LED (light-emitting diode) light-curing unit (LCU) and a halogen LCU. Twenty cylindrical specimens (3.0 mm in diameter and 2.0 mm high) were prepared for each tested material (Z100, Definite and Dyract). Specimens…