acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Gevaldo L. de Almeida”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Evaluation of the divergence of a thermal neutron beam using a Position Sensitive Detector

    Gevaldo L. de Almeida, Maria Ines Silvani, Rosanne C. A. A. Furieri e mais 2Brazilian Journal of Physics2005

    The divergence of the thermal neutron beam available at the main outlet channel of the Argonauta Reactor in the Instituto de Engenharia Nuclear has been measured by using a Position Sensitive Detector. The measurement process addressing a proper beam characterization has been conducted under several geometric…

  2. Comparison of tomographic systems for X-ray and thermal neutrons

    Maria Ines S. Souza, Gevaldo L. de Almeida, Rosanne C.A.A. Furieri e mais 3Brazilian Journal of Physics2003

    In this work, tomographic images of the same object have been taken with 25 keV X-rays and thermal neutrons (E=0.025 eV) aiming to demonstrate that thermal neutron tomography in some cases is a complementary technique to the X-ray tomography, such as in the examination of hydrogen-bearing compounds wrapped in a…

  3. Thermal neutron computed tomography at the Argonauta Reactor

    Maria Ines Silvani, Gevaldo L. de Almeida, Rosanne C. A. A. Furieri e mais 2Brazilian Journal of Physics2005

    Since 1985 the Argonauta Reactor at the Instituto de Engenharia Nuclear - IEN/CNEN has been used as a source of thermal neutrons to acquire transmission-generated radiographic images. From that time until the end of the last century, some Universities and Research Institutions have as well used the irradiation…

  4. Development of a simulator for tomographic images generated by radiation transmission

    Gevaldo L. de Almeida, Maria Ines Silvani, Rosanne C. A. A. Furieri e mais 2Brazilian Journal of Physics2004

    A computer program to simulate tomographic images generated by transmitted radiation was developed. The algorithm uses a deterministic approach to generate the projections, which supply an existing image reconstruction software. A dispersion associated with the counting statistics is also incorporated into the…

  5. Improvement of a gaseous position sensitive detector for use in thermal neutron tomographic systems

    Marcelo J. Gonçalves, Ricardo T. Lopes, Maria Ines Silvani e mais 2Brazilian Journal of Physics2004

    The utilization of a position sensitive detector in tomographic systems is an attractive possibility because it is capable of furnishing the position where the ionizing event occurs. This feature can reduce significantly the image acquiring time, since a sample translation is no longer required. In this work the…

  6. Development of a CCD-based image acquiring system for neutrons at the Argonauta Reactor

    Marcelo J. Gonçalves, Ricardo Tadeu Lopes, Maria Ines Silvani e mais 2Brazilian Journal of Physics2005

    A thermal neutron image acquiring system is being developed at the Instituto de Engenharia Nuclear-IEN (CNEN). This system would be capable to perform non-destructive assays after 2D images acquired on a real or quasi real time basis as well as 3D tomographic images reconstructed from the two-dimensional ones. The…