acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “George L. Donati”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Alternative Approaches Applied to Inductively Coupled Plasma Techniques: Multi-Flow and Two-Flow Calibration

    Raquel C. Machado, Ana Beatriz S. Silva, Daniel F. Andrade e mais 5Journal of the Brazilian Chemical Society2021

    Multi-flow calibration (MFC) is based on monitoring the analytical signal from a single calibration standard solution at several different nebulization gas flow rates (Q), which normalizes plasma conditions and minimizes matrix effects. In the present study, MFC was evaluated, for the first time, applied to…

  2. Trace Element Analysis, Model-Based Clustering and Flushing to Prevent Drinking Water Contamination in Public Schools

    Jake A. Carter, Bradley T. Jones e George L. DonatiJournal of the Brazilian Chemical Society2019

    Drinking water samples taken from cafeteria sinks and water fountains in each of the 76 schools in the Winston-Salem/Forsyth County Schools (WSFCS) district (North Carolina, United States) were analyzed by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) to determine As, Cd, Cr, Cu, Pb, Sb, Se and Tl…

  3. Strategies to improve accuracy and sensitivity in phosphorus determinations by inductively coupled plasma quadrupole mass spectrometry

    George L. Donati, Renata S. Amais e Joaquim A. NóbregaJournal of the Brazilian Chemical Society2012

    The collision/reaction interface with He introduced through the skimmer at 100 mL min-1 is employed to improve accuracy in 31P+ determinations by ICP-QMS. The 31P16O+ determination in cool plasma conditions result in limits of detection 55-fold lower. This strategy may be an interesting alternative for high ionization…

  4. Interference standard applied to sulfur determination in biodiesel microemulsions by ICP-QMS

    Renata S. Amais, George L. Donati e Joaquim A. NóbregaJournal of the Brazilian Chemical Society2012

    Determining sulfur by inductively coupled plasma mass spectrometry (ICP-MS) is not a trivial task especially due to the intense spectral interferences caused by polyatomic ions such as 16O2+, (16OH)2+, 14N16OH2+ and 14N18O+. In this work, argon species naturally present in the plasma (interference standards, IFS) are…