acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Fluorimetric method”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Development and validation of a fluorimetric method to determine curcumin in lipid and polymeric nanocapsule suspensions

    Letícia Mazzarino, Ismael Casagrande Bellettini, Edson Minatti e mais 1Brazilian Journal of Pharmaceutical Sciences2010

    A simple, rapid, and sensitive fluorimetric method was developed and validated to quantify curcumin in lipid and polymeric nanocapsule suspensions, using acetonitrile as a solvent. The excitation and emission wavelengths were set at 397 nm and 508 nm, respectively. The calibration graph was linear from 0.1 to 0.6…

  2. Sensitive single step fluorimetric method for monitoring solid-phase reactions on polystyrene resin-bound chloride groups

    Georgina E. Pina-Luis, Marco A. Zazueta Gómez, Ignacio A. Rivero Espejel e mais 1Journal of the Brazilian Chemical Society2011

    Fluorescence spectroscopy has been used to monitor the chemical conversion of resin-bound chloride groups. The time-concentration profiles of different reactions involving the incorporation of hydroxyphenylethanone (HPE) derivatives to Merrifield resin and 2-aminobencylalcohol (ABA) to a chlorosulphonate resin are…

  3. Fluorimetric method for the determination of erythromycin using a photochemical derivatization approach

    Virginia de L. M. Finete, Márcia Arissawa e Ricardo Q. AucélioJournal of the Brazilian Chemical Society2008

    Photochemical derivatization was proposed to enable intense fluorescence (412/465 nm) from erythromycin. Crucial experimental parameters such as type and concentration of the acid used to treat analyte solutions and UV irradiation time were adjusted. Limits of detection and quantification of 0.025 and 0.085 µg mL-1…

  4. A fast fluorimetric flow injection method to determine ibuprofen

    Adriana G. Lista, Miriam E. Palomeque e Beatriz S. Fernández BandJournal of the Brazilian Chemical Society2006

    The native fluorescence of ibuprofen was enhanced when a host-guest complex of the analyte with beta cyclodextrin (beta-CD) was formed. So, based on this fact, a flow injection method to determine ibuprofen in different pharmaceutical preparations with fluorescence detection (lambdaem 287 nm, lambdaexc 223 nm) was…

  5. Development of a fluorimetric sequential injection analysis (SIA) methodology for determination of quinine

    Carlos M. C. Infante e Jorge C. MasiniJournal of the Brazilian Chemical Society2011

    A sequential injection analysis (SIA) methodology was developed for fluorimetric determination of quinine in soft drinks. Minimum dispersion and efficient mixing were achieved by aspirating 200 mL of sample between two 100 mL reagent zones (0.10 mol L-1 H2SO4) at flow rate of 250 mL s-1 and using a reaction coil…

  6. A method for determination of ammonia in air using oxalic acid-impregnated cellulose filters and fluorimetric detection

    Erika P. Felix e Arnaldo A. CardosoJournal of the Brazilian Chemical Society2012

    A fluorimetric method was developed for the determination of ammonia in ambient air. Samples were collected using cellulose filters impregnated with oxalic acid, followed by solubilization of the ammonium ion, addition of reagents and fluorimetric detection. Important analytical parameters that were evaluated included…