acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Fixed partial denture”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Fracture load resistance of pontic with different connector designs: three-unit implant-supported fixed partial denture

    Enas Kareem Mohammed, Saja Ali Muhsin, Ahmed Ali Mohammed e mais 1Brazilian Journal of Oral Sciences2025

    Aim This in-vitro study aims to assess the fracture load resistance of the central pontic of two implant-supported zirconia fixed partial dentures (FPDs) using five alternative connector designs. Methods The CAD/CAM production technique was used to mill the FPD of a three-unit zirconia prosthesis (from the mandibular…

  2. Ultraconservative fixed partial denture: esthetic and preservation of dental structure

    Wilson MATSUMOTO, Rossana Pereira de Almeida ANTUNES, Regina Maura FERNANDES e mais 2RGO - Revista Gaúcha de Odontologia2014

    The oral rehabilitation can be made with several ways with the objective to reestablish the masticatory function and the esthetic of the patient. The aim of this clinical case is to present a different type of fixed partial denture, as alternative option to the dental surgeon, showing particularities like indications…

  3. All-ceramic and porcelain-fused-to-metal fixed partial dentures: a comparative study by 2D finite element analyses

    Andréa Barreira Motta, Luiz Carlos Pereira e Andréia R.C.C da CunhaJournal of Applied Oral Science2007

    All-ceramic fixed partial dentures (FPDs) have an esthetic approach for oral rehabilitation. However, metal-ceramic FPDs are best indicated in the posterior area where the follow-up studies found a lower failure rate. This 2D finite element study compared the stress distribution on 3-unit all-ceramic and metal-ceramic…

  4. Data collection about failures in fixed partial dentures: 1-year monitoring

    Adriana Cristina ZAVANELLI, José Vitor Quinelli MAZARO, Pâmella Izza NÓBREGA e mais 2RGO - Revista Gaúcha de Odontologia2018

    ABSTRACT Objective: The aim of this study was to evaluate the satisfaction of patients rehabilitated with fixed partial denture and the incidence of failures/clinical complications of prostheses after one year. Methods: The patients answered a questionnaire about the satisfaction degree with dental treatment performed…

  5. Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

    Marcia Borba, Walter Gomes Miranda Jr., Paulo Francisco Cesar e mais 2Brazilian Oral Research2013citado por 3 artigos

    The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to…

  6. Fixed partial prosthesis impression: conventional versus digital method

    Elisa Camargo Kukulka, Joyce Rodrigues de Souza, Michelle de Sá dos Santos Gomes e mais 2RGO - Revista Gaúcha de Odontologia2024

    ABSTRACT The systematic review of the literature aimed to compare the conventional and digital impression methods for making fixed partial dentures using the current literature and to verify the applicability of the methods in the clinical routine. A search was carried out in the PubMed database using the keywords…

  7. The importance of properly distributing the occlusal load for the correct biomechanics of implant-supported fixed partial dentures: stress analysis in implants, prosthetic components and infrastructures

    Silvio Pedro da Silva SAKAMOTO, Diogo Henrique Vaz de SOUZA, Andrea Sayuri Silveira Dias TERADA e mais 2RGO - Revista Gaúcha de Odontologia2023

    ABSTRACT Objective: The present study analyzed the biomechanical behavior of the generated stress on the external surface of the rehabilitation elements (implants, components and infrastructures) according to different occlusion patterns on a fixed partial denture on osseointegrated implants. Method: The experimental…

  8. Fixed partial dentures in an up to 8-year follow-up

    Maximiliano Sérgio Cenci, Paulo Antônio da Rosa Rodolpho, Tatiana Pereira-Cenci e mais 2Journal of Applied Oral Science2010

    Information on the longevity of fiber-reinforced composite fixed partial dentures (inlay FPDs) should be considered in the selection of materials, operative techniques and patient instructions related to prognosis and long-term cost-effectiveness. OBJECTIVE: This study evaluated the long-term survival of…

  9. Fracture strength of composite fixed partial denture using bovine teeth as a substitute for human teeth with or without fiber-reinforcement

    Carlos José Soares, Liliane Minglini Barbosa, Fernanda Ribeiro Santana e mais 3Brazilian Dental Journal2010

    This study evaluate the use of bovine teeth as a substitute for human teeth on fracture strength tests of composite fixed partial dentures (Cpd), with and without fiberglass reinforcement (Fg). Eighty teeth were selected, being 40 bovine incisors, 20 human premolars and 20 molars. Bovine incisors were ground to get a…

  10. Effect of pontic framework design on the fracture resistance of implant-supported all-ceramic fixed partial dentures

    Ozgur Inan, Asli Secilmis e Oguz EraslanJournal of Applied Oral Science2009

    OBJECTIVE: The purpose of this study was to compare the fracture resistance of implant-supported all-ceramic fixed partial dentures, which have three different pontic designs. MATERIAL AND METHODS: Two implants were placed in a metal model simulating mandibular left second premolar and mandibular left second molar…

  11. Residual stress estimated by nanoindentation in pontics and abutments of veneered zirconia fixed dental prostheses

    Vinicius Pavesi Fardin, Gerson Bonfante, Paulo G. Coelho e mais 6Journal of Applied Oral Science2022

    Abstract Glass ceramics’ fractures in zirconia fixed dental prosthesis (FDP) remains a clinical challenge since it has higher fracture rates than the gold standard, metal ceramic FDP. Nanoindentation has been shown a reliable tool to determine residual stress of ceramic systems, which can ultimately correlate to…

  12. Cost-Effectiveness Analysis of Single-Tooth Rehabilitation Options

    Manuel Henrique de Medeiros Neto, Rênnis Oliveira da Silva, Leopoldina de Fátima Dantas de Almeida e mais 4Pesquisa Brasileira em Odontopediatria e Clínica Integrada2024

    ABSTRACT Objective: To evaluate the cost-effectiveness of single-tooth rehabilitation options with dental implants associated with a prosthetic crown (I+C) compared to a fixed partial denture (FPD). Material and Methods: A rapid review was carried out to identify the costs (expressed in US$) and effectiveness…

  13. Anatomic landmarks in the maxilla for guidance of anterior prosthetic teeth positioning

    Fernando Marques Barbosa Porfirio, Dauro Douglas Oliveira, Betania Guedes Cruz e mais 4Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2020

    Abstract Objectives: To obtain data supporting the establishment of bony anatomical parameters to guide the proper arrangement of anterior artificial teeth in the maxilla. Methods: A total of 60 skulls with all permanent anterior teeth, Angle Class I molar relationship, overjet and overbite of up to 3 mm, and…

  14. Metal-ceramic partial fixed dentures: a retrospective study

    Fernanda Ferruzzi LIMA, Fabíola Pontes AZEVEDO, Bárbara Margarido BRONDINO e mais 5RGO - Revista Gaúcha de Odontologia2020

    ABSTRACT Objective Metal-ceramic prosthesis are the treatment of choice in oral rehabilitation because of their high survival rates. However, there are few reports in the scientific literature about factors that lead to fractures of metal-ceramic prostheses. The aim of this study was to evaluate whether prostheses…

  15. Evaluation of mechanical properties of CAD/CAM ceramic systems: literature review

    Ana Emanuela Cisne de LIMA, Hilmo Barreto Leite FALCÃO FILHO e Helena de Freitas Oliveira PARANHOSRGO - Revista Gaúcha de Odontologia2020

    ABSTRACT Computer aided design / computer aided manufacturing (CAD/CAM) systems are among the most technological advanced techniques in oral rehab today. Compared with conventional techniques, they can optimize the resistance and the adaptation of dental ceramics. Thus, their indications of use have been widened…

  16. Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures

    Valdey SUEDAM, Rafael Tobias MORETTI NETO, Edson Antonio Capello SOUSA e mais 1Journal of Applied Oral Science2016citado por 2 artigos

    ABSTRACT Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of…

  17. Influence of diameter and intraradicular post in the stress distribution. Finite element analysis

    Cleidiel Aparecido Araujo LEMOS, Daniel Augusto de Faria ALMEIDA, Victor Eduardo de Souza BATISTA e mais 4Revista de Odontologia da UNESP2016citado por 1 artigo

    Abstract Introduction The biomechanical behavior of endodontically treated teeth depending on the selected restorative material and tooth situation to be restored. Objective To analyze by the two-dimensional finite element method the biomechanical behavior of different diameters in intraradicular posts and teeth with…

  18. Evaluation of the pattern dimensions of cast-metal posts in uniradicular teeth

    Rafael de Assunção Vital, Jessica Silva Ribeiro e Sicknan Soares da RochaRevista de Odontologia da UNESP2015citado por 1 artigo

    Introduction Accurate dimensions of cast-metal posts are relevant to the survival of dental prostheses. Objective The aim of this study was to verify if the dimensions of cast-metal posts accord with ideal clinical criteria. Material and method For the evaluation, 285 periapical radiographs, from a total of 80 teeth…

  19. Importance of a distal proximal contact on load transfer by implant-supported single adjacent crowns in posterior region of the mandible: a photoelastic study

    Fabio Afranio de Aguiar Junior, Rodrigo Tiossi, Ana Paula Macedo e mais 3Journal of Applied Oral Science2013

    OBJECTIVE: This study aimed to evaluate the importance of a distal proximal contact on the load transfer to the posterior region of the mandible by non-splinted adjacent implant-supported crowns using photoelastic stress analysis. MATERIAL AND METHODS: A rectangular model (68x30x15 mm) was made of…

  20. Antimicrobial efficacy of chemical disinfectants on contaminated full metal crowns

    Iara Augusta Orsi, Camilo Andrés Villabona, Eliana Kameoka e mais 3Brazilian Dental Journal2010citado por 1 artigo

    Prosthetic restorations that have been tried in the patient's mouth are potential sources of infection. In order to avoid cross-infection, protocols for infection control should be established in dental office and laboratory. This study evaluated the antimicrobial efficacy of disinfectants on full metal crowns…