acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Equipment Design”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. The Italian Office Desk: ‘Mass production and one-off piece’ towards the modernity

    Imma ForinoConvergências - Revista de Investigação e Ensino das Artes2020

    Abstract In Italy the history of modern equipment design has shifted between ‘mass production and one-off’, as architects Gio Ponti and Antonio Fornaroli wrote in an article in the magazineDomus(1948). Starting from this important reflection by the two Italian architects, the article takes into consideration the case…

  2. Evaluation of manual resuscitators used in ICUs in Brazil

    Tatiana de Arruda Ortiz, Germano Forti Junior, Marcia Souza Volpe e mais 4Jornal Brasileiro de Pneumologia2013

    OBJECTIVE: To evaluate the performance of manual resuscitators (MRs) used in Brazil in accordance with international standards. METHODS: Using a respiratory system simulator, four volunteer physiotherapists employed eight MRs (five produced in Brazil and three produced abroad), which were tested for inspiratory and…

  3. PROTOCOLO DIGITAL PARA PROJETO CONCEITUAL E VALIDAÇÃO DE UMA ÓRTESE TORNOZELO-PÉ

    Rui Araújo Júnior e Patrícia Maria de Moraes Barros FucsActa Ortopédica Brasileira2025

    Abstract Objective: This original article aimed to develop a digital protocol for the conceptual design and validation of Ankle-Foot Orthoses (AFO) using 3D mapping technologies. Methods: A scanned model of the ankle-foot complex of a 12-year-old child with a drop foot was utilized, along with a generic AFO model from…

  4. A Multidisciplinary Design Optimization Tool for Spacecraft Equipment Layout Conception

    Valentino Lau, Fabiano Luis de Sousa, Roberto Luiz Galski e mais 4Journal of Aerospace Technology and Management2014citado por 2 artigos

    ABSTRACT: One issue the design team has to face in the process of building a new spacecraft, is to define its mechanical and electrical architecture. The choice of where to place the spacecraft´s electronic equipment is a complex task, since it involves simultaneously many factors, such as the spacecraft's required…

  5. Application of product development tools in equipment design for a technology-based small business

    Felipe Mello Pierobom e Jairo José de Oliveira AndradeGestão & Produção2020

    Abstract: The main objective of this paper is to use the techniques and methods of Product Process Development in the equipment development for a technology-based small business. Conceptual design concepts were generated and through the use of a morphological matrix the options of confection of the final conceptual…

  6. Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology

    Letícia Helena Lunardi, Danielle Arroyo, Marcelo Vicente de Andrade Sobrinho e mais 2Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Purpose: Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical…

  7. Feasibility of transthoracic echocardiography in the prone position with a low-cost adaptation: morphological, functional, and hemodynamic analysis

    Nilson Bossle Conci, Nathalia Conci Santorio, Pandreli Testa Santorio e mais 3einstein (São Paulo)2026

    ABSTRACT Objective: Transthoracic echocardiography is essential for hemodynamic assessment in critically ill patients; however, its use in the prone position remains challenging. This study aimed to assess the feasibility of performing transthoracic echocardiography using a low-cost ultrasound table adaptation in the…

  8. Proposal of a new slit-lamp shield for ophthalmic examination and assessment of its effectiveness using computational simulations

    Daniel Araújo Ferraz, Zeyu Guan, Edinilson A. Costa e mais 7Arquivos Brasileiros de Oftalmologia2023

    ABSTRACT Purpose: This study aimed to use computational models for simulating the movement of respiratory droplets when assessing the efficacy of standard slit-lamp shield versus a new shield designed for increased clinician comfort as well as adequate protection. Methods: Simulations were performed using the…

  9. The Canabrava Ring, an open ring-shaped pupil expander for cataract surgery associated with iris colobomata: a case report

    Sérgio Canabrava, Ana Carolina Canêdo Domingos Lima e Ana Elisa LoyolaArquivos Brasileiros de Oftalmologia2020

    ABSTRACT In this report, we describe a new pupil expander device that was used to obtain adequate pupil dilation and centering in a patient with an iris coloboma. Specifically, we describe the case of a patient with an iris coloboma; a Malyugin ring was inserted to facilitate dilation during phacoemulsifi­cation…

  10. Safe Embrace: technological innovation for elderly safety in the use of toilets

    Luciana Mitsue Sakano Niwa, Nanci Martins Ferreira Radovich, Eliseth Ribeiro Leão e mais 1Revista Brasileira de Enfermagem2018citado por 2 artigos

    ABSTRACT Objective: to describe the development of a device to prevent falling for seniors when using the toilet. Method: we sought in literature and in the hospital market for a device to prevent falling, without success. Geriatric nurses, in partnership with the hospital engineering team, elaborated a prototype and…

  11. Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems

    Umit Ubeyt Inan, Onur Polat, Sibel Inan e mais 2Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR) undergoing panretinal photocoagulation (PRP) using either pattern scan laser (PASCAL) or navigated laser photocoagulation (NAVILAS). Methods: Patients diagnosed with PDR were randomly assigned to undergo either…

  12. Comparison between refraction measured by Spot Vision ScreeningTM and subjective clinical refractometry

    Daniela Lima de Jesus, Flávio Fernandes Villela, Luis Fernando Orlandin e mais 3Clinics2016citado por 1 artigo

    OBJECTIVE: The purpose of this study was to evaluate the accuracy of Spot Vision ScreeningTM as an autorefractor by comparing refraction measurements to subjective clinical refractometry results in children and adult patients. METHODS: One-hundred and thirty-four eyes of 134 patients were submitted to refractometry by…

  13. Mini-flared Kelman tip, reverse tip, and sidewinder tip with torsional phaco: a prospective randomized comparative study

    Wilson Takashi Hida, Patrick Frensel Tzelikis, Celso Takashi Nakano e mais 2Arquivos Brasileiros de Oftalmologia2015

    Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the…

  14. Development of an aspheric 22-diopter 50-mm diameter magnifier

    José Américo Bonatti, Fernanda Alves da Silva Bonatti, Maria Cecília Loschiavo dos Santos e mais 2Arquivos Brasileiros de Oftalmologia2008

    PURPOSE: To develop in an interdisciplinary approach between ophthalmology and design areas an ergonomic +22-diopter 50-mm aspheric hand magnifier for low vision. METHODS: An aluminum cylinder was cut, processed using a lathe and carved to produce a ring that accommodated a 50-mm aspheric lens, with an external…

  15. Anesthetic experimental device for small animal

    Luiz Alfredo de Magalhães Vivas, Nelson Jamel, Ricardo Antonio Refinetti e mais 4Acta Cirúrgica Brasileira2007citado por 2 artigos

    PURPOSE: The difficulty to anesthetize small laboratory animals with vaporizer prompted us to go in search of new materials, and create new techniques. The improved equipment of anesthesia we looked for should be low cost, practical, versatile, and its management serve ethical, teaching, and research purposes…

  16. Preliminary results of a high-resolution refractometer using the Hartmann-Shack wave-front sensor: part I

    Luis Alberto Carvalho, Antonio Carlos Romao, Marcos Stefani e mais 7Arquivos Brasileiros de Oftalmologia2003

    In this project we are developing an instrument for measuring the wave-front aberrations of the human eye using the Hartmann-Shack sensor. A laser source is directed towards the eye and its diffuse reflection at the retina generates an approximately spherical wave-front inside the eye. This wave-front travels through…

  17. National equipment of intraoperatory gamma detection in the identification of sentinel lymph node in animal model

    Paula Cristina Fada dos Santos, Ivan Dunshee de Abranches Oliveira Santos, Fábio Xerfan Nahas e mais 2Acta Cirúrgica Brasileira2009citado por 1 artigo

    PURPOSE: To investigate a national equipment of intraoperatory gamma detection in the identification of sentinel lymph node. METHODS: Thirty young adult male rats were used. After anesthetized, animals were divided into two groups of 15 animals each. Animals from group A received dextram 500 - Tc99 radiopharmaceutical…

  18. Construction and enhancement of a prototype for a medical-hospital equipment for hypodermoclysis: a qualitative study

    Thayna Silva de Assis Barros, Eduardo José Ferreira Santos, Pedro Miguel dos Santos Dinis Parreira e mais 4Revista Brasileira de Enfermagem2024citado por 1 artigo

    ABSTRACT Objectives: to construct a Subcutaneous Hydration Device semi-functional prototype and gather initial information to improve this prototype design and realize its acceptance potential. Methods: a qualitative, descriptive and exploratory study, which used focus group, following the Technology Acceptance Model…

  19. Usability evaluation of an innovative device for hypodermoclysis in a simulated scenario with nurses

    Thayna de Assis Barros S. Thiago, Eduardo José Ferreira Santos, Pedro Miguel dos Santos Dinis Parreira e mais 5Revista Latino-Americana de Enfermagem2026

    Objective: to evaluate the usability and operational performance of the Subcutaneous Hydration Device prototype in a simulated scenario with nurses, as well as to gather input for its continuous refinement. Method: pre-experimental, qualitative, and quantitative usability study using a simulated scenario…

  20. Research in Design for the health emergency. COVID-19, experiments and relationships to promote new solutions.

    Maria Antonietta Sbordone, Barbara Pizzicato, Carmela Ilenia Amato e mais 2Convergências - Revista de Investigação e Ensino das Artes2021

    Abstract The Pandemic has forced change, raising questions about design models, business models, incentives and community education. The urgency of containment measures has redefined the role of health and highlighted the role of Design, which is involved in emergency situations, in designing the universe of…