acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Dosimetry”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Beyond the Badge: Bridging Physical and Biological Monitoring to Strengthen Occupational Radiation Safety

    IANKA LARYSSA LACERDA-ALVES, LUCIANO RODOLFO FERREIRA-LUCENA, ANDRÉ MACIEL NETTO e mais 3Anais da Academia Brasileira de Ciências2026

    Abstract Cytogenetic dosimetry (CD) provides biological evidence of radiation exposure and is particularly valuable in emergencies. However, its routine use in occupational protection remains limited globally. This study examines the barriers to institutionalization of CD within Brazil’s occupational health and safety…

  2. Development of a glycerol–CuSO4 polymer for high gamma ionizing radiation dosimetry

    Gabriela Pontes Cardoso, Jony Marques Geraldo e Adriana de Souza Medeiros BatistaPolímeros2026

    Abstract This study presents a novel glycerol-based polymeric material doped with 0.12% (w/w) copper (II) sulfate pentahydrate for high-dose gamma dosimetry. Upon irradiation with doses ranging from 10 to 250 kGy using a Cobalt-60 source, the initially greenish material exhibited a progressive color change from yellow…

  3. PLA-Based Simulator for Dosimetry Assessment of Healthcare Waste

    H. L. L. Silva, N. A. M. Cussiol e T. P. R. CamposBrazilian Journal of Radiation Sciences2026

    Abstract Healthcare waste (HCW) requires efficient treatment prior to final disposal to prevent the spread of pathogens and environmental contamination. Ionizing irradiation has emerged as a promising alternative to incineration; however, accurate absorbed-dose determination depends on knowledge of the material’s…

  4. Monte Carlo simulation of a 6 MV Varian Trilogy clinical linear accelerator using Geant4 for small-field dosimetry analysis

    A. L. C. Ribeiro, A. C. H. De Oliveira, L. P. Da Silva e mais 1Brazilian Journal of Radiation Sciences2025

    In recent decades, radiotherapy has advanced significantly due to the emergence of advanced clinical linear accelerators, enabling safer and faster treatments with reduced side effects. In this study, we present a Monte Carlo simulation of a 6 MV Varian Trilogy clinical linear accelerator using the Geant4 toolkit to…

  5. Validation of automated image co-registration integrated into in-house software for voxel-based internal dosimetry on single-photon emission computed tomography images

    André Luiz Alberti Leitão, Uysha de Souza Fonda, Carlos Alberto Buchpiguel e mais 2Radiologia Brasileira2023

    Abstract Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in…

  6. Evaluation of the dosimetry and centralization of scout-view function in CBCT

    Danúsia da Silva Vilela, Luiz Roberto Coutinho Manhães Júnior, Monikelly do Carmo Chagas Nascimento e mais 3Brazilian Dental Journal2022

    Abstract This study evaluated the centralization of the region of interest (ROI) in acquisition of the CBCT images, when the freely positionable scout-view (SV) function is applied. Additionally, the dosimetry of the acquired images was assessed in the SV function alone as well as in complete tomographic image in two…

  7. Radionuclide therapy: current status and prospects for internal dosimetry in individualized therapeutic planning

    Marcelo Tatit Sapienza e José WillegaignonClinics2019citado por 1 artigo

    The efficacy and toxicity of radionuclide therapy are believed to be directly related to the radiation doses received by target tissues; however, nuclear medicine therapy continues to be based primarily on the administration of empirical activities to patients and less frequently on the use of internal dosimetry for…

  8. Dosimetry in CBCT with Different Protocols: Emphasis on Small FOVs Including Exams for TMJ

    Helena Aguiar Ribeiro Nascimento, Marcos Ely Almeida Andrade, Marco Antonio Gomes Frazão e mais 3Brazilian Dental Journal2017citado por 1 artigo

    Abstract This study aimed to estimate the absorbed dose in cone beam computed tomography (CBCT) exams according to different exposure parameters and size and position of the field of view (FOV). In addition was compared the absorbed dose of two smaller FOV scans with that of a larger FOV scan for evaluation of…

  9. Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center

    Priscila do Carmo Santana, Paulo Marcio Campos de Oliveira, Marcelo Mamede e mais 4Radiologia Brasileira2015citado por 2 artigos

    Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT…

  10. Accuracy of dose planning for prostate radiotherapy in the presence of metallic implants evaluated by electron spin resonance dosimetry

    G.G. Alves, A. Kinoshita, H.F. de Oliveira e mais 3Brazilian Journal of Medical and Biological Research2015

    Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose…

  11. Reconstructive dosimetry for cutaneous radiation syndrome

    C.M.A. Lima, A.R. Lima, Ä.L. Degenhardt e mais 2Brazilian Journal of Medical and Biological Research2015

    According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in…

  12. Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors

    Sâmia de Freitas Brandão e Tarcísio Passos Ribeiro de CamposRadiologia Brasileira2013

    Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with…

  13. Manufacturing polycrystalline pellets of natural quartz for applications in thermoluminescence dosimetry

    Álvaro Barbosa de Carvalho Junior, Thiago Fernandes Barros, Pedro Luiz Guzzo e mais 1Materials Research2012

    This paper describes the manufacturing process of quartz-pellets and shows their potential use as thermoluminescence dosimeters (TLD) for those applications where low-levels of ionising radiation are present. Two batches of cold-pressed pellets were produced and their resistance were evaluated by vibration tests and…

  14. The use of fricke dosimetry for low energy x-rays

    Carlos de Austerlitz, Viviane Souza, Heldio Pereira Villar e mais 1Brazilian Archives of Biology and Technology2006

    The performance of four X-ray qualities generated in a Pantak X-ray machine operating at 30-100 kV was determined with a parallel-plate ionization chamber and a Fricke dosimeter. X-ray qualities used were those recommended by Deutsch Internationale Normung DIN 6809 and dose measurements were carried out with…

  15. Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors

    José Eduardo Manzoli, Vicente de Paulo de Campos e Mirian Saori DoiBrazilian Archives of Biology and Technology2006

    Measurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evaluations concerned to…

  16. Physical and biological dosimetry for risk perception in radioprotection

    Ademir AmaralBrazilian Archives of Biology and Technology2005citado por 4 artigos

    The increase in ionizing radiation (IR) applications, especially nuclear, has been followed by the growth of public concern for the potential associated risks. The public’s perception of such risks is often based on the philosophy that IR is harmful at any exposure level. On the other hand, although radiation workers…

  17. Trends in biological dosimetry: an overview

    Ademir AmaralBrazilian Archives of Biology and Technology2002citado por 3 artigos

    Biological dosimetry (biodosimetry) is based on investigations of induced biological effects (biomarkers) in order to correlate them with radiation dose. Among the indicators employed in biodosimetry, scoring of chromosome aberrations is the most reliable method to quantify individual exposure to ionizing radiation…

  18. Ionizing Radiation Dosimetry on Lunar Habitats: Analyzing Current Research

    Camilo Revelo-Benavides, Carlos Patiño, Arturo Argüelles e mais 1Journal of Aerospace Technology and Management2026

    ABSTRACT Establishing a permanent and sustainable human presence on the Moon has long been one of humanity’s most ambitious goals. The Moon is continuously exposed to ionizing radiation from the Sun and deep space, rendering it an extreme environment that poses significant radiological risks to future human…

  19. Comparative Study of Thermal Neutron Flux from Gold Foil Activation

    Watila Lins Silva, Max Santos Ramos, Regio Santos Gomes e mais 2Brazilian Journal of Radiation Sciences2026

    Abstract This study presents a comparative analysis between Monte Carlo simulations (MCNP-5) and experimental measurements of thermal neutron fluence using gold foil activation at the TNF2 irradiation facility of the Neutron Metrology Laboratory (LNMRI/IRD). The MCNP-5 model was constructed to replicate the irradiator…

  20. Application of Optically Stimulated Luminescence Dosimeters in the Evaluation of the Dose Map Software in Interventional Radiology

    E.S. Santos, D.Y. Nersissian e E.M. YoshimuraBrazilian Journal of Radiation Sciences2026

    Abstract Interventional radiology is widely employed; however, the complexity and duration of certain procedures may result in significant radiation exposure to patients. This study presents a comparison between a commercial computational dose mapping method used in interventional radiology, Dose Map, and optically…