acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Dental implant”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Influence of metal bar lever-arm on screws detorque for dental prosthesis implant supported

    Wilson MATSUMOTO, Ana Paula MACEDO, Rossana Pereira de ALMEIDA e mais 2Revista de Odontologia da UNESP2020

    Abstract Introduction The cantilever length of implant-supported fixed prosthesis metal structure has been considered an important factor to transfer occlusion forces to the dental implant. Objective This study evaluated the influence of different extensions of cantilevers of Branemark protocol implant prosthesis when…

  2. Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks (I-Bridge®2) before and after cyclic mechanical loading

    Marc Philipp Dittmer, Moritz Nensa, Meike Stiesch e mais 1Journal of Applied Oral Science2013

    Implant-supported screw-retained fixed dental prostheses (FDPs) produced by CAD/ CAM have been introduced in recent years for the rehabilitation of partial or total endentulous jaws. However, there is a lack of data about the long-term mechanical characteristics. OBJECTIVE: The aim of this study was to investigate the…

  3. Load-Application Devices: A Comparative Strain Gauge Analysis

    Renato Sussumu Nishioka, Luis Gustavo Oliveira de Vasconcellos, Renata Pilli Jóias e mais 1Brazilian Dental Journal2015

    In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and…

  4. Screwed and cement implant prosthesis: current clinical considerations

    Bruna Palmeira COSTA, Julliana Cariry Palhano FREIRE, Waleska Ohana de Souza MELO e mais 3RGO - Revista Gaúcha de Odontologia2021

    ABSTRACT Introduction: There is no consensus as to which cemented or screwed retention system is best to avoid bone loss around the implant from a fixed implant-supported restoration. Objective: To evaluate the prosthesis retention systems on screw and cemented implants, regarding: bone loss, survival and failure…

  5. Effect of veneering material on the deformation suffered by implant-supported fixed prosthesis framework

    Antônio Francisco GRANDO, Carlos Eduardo Edwards REZENDE, Edson Antônio Capello SOUSA e mais 1Journal of Applied Oral Science2014

    Knowing how stresses are dissipated on the fixed implant-supported complex allows adequate treatment planning and better choice of the materials used for prosthesis fabrication. Objectives: The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast…

  6. Impact of cement- and screw- retained implant prostheses on marginal bone loss: overview of systematic reviews

    João Vicente Calazans Neto, Cícero Andrade Sigilião Celles, Maria Helena Rossy Borges e mais 4Brazilian Journal of Oral Sciences2025

    Aim The choice between retention systems in implant-supported prostheses impacts marginal bone loss (MBL), a key factor for implant longevity. Due to variability in the findings of systematic reviews, this overview aims to assess the methodological quality and synthesize available evidence from systematic reviews on…

  7. Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis

    Grazielle Franco Gomes, Mónica Estefanía Tinajero Aroni, Lucas Portela Oliveira e mais 3Brazilian Journal of Oral Sciences2023

    Aim To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implant-prosthetic rehabilitation three-dimensionally. Methods A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare…

  8. Peri-Implant Bone Loss of External Hexagon and Morse Taper in Patients Wearing Immediately Loaded Overdentures

    Laércio Almeida de Melo, Mariana Barbosa Câmara de Souza, Gustavo Augusto Seabra Barbosa e mais 1Brazilian Dental Journal2017citado por 2 artigos

    Abstract The aim of this study was to evaluate the peri-implant bone loss of External Hexagon (EH) and Morse Taper (MT) implants in patients wearing immediately loaded mandibular overdentures during a 1-year follow-up. This is a non-randomized controlled clinical trial including 18 MT and 22 EH implants. Periapical…

  9. Implant-based factor as possible risk for peri-implantitis

    Daniela Leal ZANDIM-BARCELOS, Gabriel Garcia de CARVALHO, Vitor Marques SAPATA e mais 3Brazilian Oral Research2019

    Abstract Peri-implantitis is currently a topic of major interest in implantology. Considered one of the main reasons of late implant failure, there is an emerged concern whether implant characteristics could trigger inflammatory lesion and loss of supporting bone. The purpose of this narrative review is to provide an…

  10. Influence of crown and hybrid abutment ceramic materials on the stress distribution of implant-supported prosthesis

    João Paulo Mendes TRIBST, Amanda Maria de Oliveira DAL PIVA, Alexandre Luiz Souto BORGES e mais 1Revista de Odontologia da UNESP2018citado por 3 artigos

    Abstract Introduction A new dental implant-abutment design is available with the possibility of improving aesthetic with no compromise of mechanical strength, using perforated CAD/CAM ceramic blocks. Objective This study evaluated the influence of crown and hybrid abutment ceramic materials combination on the stress…

  11. Effects of different torque levels on the implant-abutment interface in a conical internal connection

    Sergio Alexandre GEHRKE, Jamil Awad SHIBLI, Jaime Sardá ARAMBURÚ JUNIOR e mais 3Brazilian Oral Research2016citado por 1 artigo

    Abstract The fit of the implant-abutment interface was assessed by the metallographic technique and by scanning electron microscopy (SEM), using solid abutment types at different torque levels. Forty Morse taper connections and forty solid abutments were used at different torque levels (repeated after 10 minutes) in…

  12. Machined and plastic copings in three-element prostheses with different types of implantabutment joints: a strain gauge comparative analysis

    Renato Sussumu Nishioka, Lea Nogueira Braulino de Melo Nishioka, Celina Wanderley Abreu e mais 2Journal of Applied Oral Science2010citado por 2 artigos

    OBJECTIVE: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of…

  13. Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis

    Luis Gustavo Oliveira de Vasconcellos, Renato Sussumu Nishioka, Luana Marotta Reis de Vasconcellos e mais 1Journal of Applied Oral Science2011citado por 2 artigos

    OBJECTIVES: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. MATERIAL AND METHODS: Three internal hexagon implants were linearly…

  14. Importance of a distal proximal contact on load transfer by implant-supported single adjacent crowns in posterior region of the mandible: a photoelastic study

    Fabio Afranio de Aguiar Junior, Rodrigo Tiossi, Ana Paula Macedo e mais 3Journal of Applied Oral Science2013

    OBJECTIVE: This study aimed to evaluate the importance of a distal proximal contact on the load transfer to the posterior region of the mandible by non-splinted adjacent implant-supported crowns using photoelastic stress analysis. MATERIAL AND METHODS: A rectangular model (68x30x15 mm) was made of…

  15. Total removal of the buccal flange in maxillary prosthetic preparation: a necessity?: case report

    Stephanie Gomes Assunção Alves, Lorena Gonçalves Alexandrino, Gustavo Eduardo Casagrande e mais 2RGO - Revista Gaúcha de Odontologia2024

    ABSTRACT Fixed implant-supported complete maxillary dentures aim to rehabilitate aesthetic, phonetic, and functional aspects of edentulous arches. A previous prosthetic preparation without a flange in the anterior sector makes it possible to evaluate the labial support and the existing space for the future prosthesis…

  16. Profilaxis antibiótica en implantología oral. Revisión crítica de la literatura

    Ángel-Orión Salgado-Peralvo, Javier Sanz-Esporrín, María-Victoria Mateos-Moreno e mais 3Revista Española de Cirugía Oral y Maxilofacial2019citado por 1 artigo

    RESUMEN La masiva difusión de los tratamientos implantológicos conlleva, según los patrones de prescripción actuales, la administración de antibióticos profilácticos, los cuales no están indicados en la mayoría de los casos; sin embargo, su uso suele basarse en la experiencia del operador, en muchos casos influenciado…

  17. Implant prosthesis in patients with bruxism

    Bruna Almeida Wandekoken, Bruno Machado de Carvalho, Jimmy de Oliveira Araujo e mais 3RGO - Revista Gaúcha de Odontologia2024

    ABSTRACT Objective: This study aimed to review the literature on the types of treatments proposed for patients with bruxism and implant supported, discussing a treatment protocol for those patients, for the purpose of prolonging the treatment longevity. Methods: A literature search in MEDLINE (PubMed), Google Scholar…

  18. Tightening techniques for the retaining screws of universal abutment

    Alexandre Wittcinski REGALIN, Rodrigo ALESSANDRETTI, Leonardo FEDERIZZI e mais 3Revista de Odontologia da UNESP2016

    Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm…

  19. A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution

    Sandra Lucia Dantas de Moraes, Fellippo Ramos Verri, Joel Ferreira Santiago Junior e mais 3Brazilian Dental Journal2013citado por 3 artigos

    The purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by…

  20. The assessment of periimplant soft tissue condition with morse taper abutment connection: a rapid review

    Puspa Puspita Lasminingrum, Aldilla Miranda, Dyah Nindita Carolina e mais 1Brazilian Journal of Oral Sciences2022

    Aim This study aims to evaluate the clinical assessment results of periimplant soft tissue with morse taper (internal abutment connection). Methods The study was conducted using a rapid review by searching the articles from PubMed NCBI and Cochrane by using keywords. All articles were selected by the year…