acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Dental digital radiography”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Comparison of the Accuracy of Digital Radiography with Conventional Radiography and Visual Examination in the Detection of Permanent Teeth Interproximal Caries

    Hamid Taghiloo, Sina Taghiloo, Mahdi Rahbar e mais 1Pesquisa Brasileira em Odontopediatria e Clínica Integrada2019citado por 1 artigo

    Abstract Objective: To compared the accuracy of digital radiography in the diagnosis of interproximal caries in permanent teeth with conventional radiography and visual examination. Material and Methods: In this descriptive-analytical study, 78 human premolars, which seem normal in primary examination, are mounted on…

  2. Evaluation of the maxillary premolar roots dissociation using radiographic holders with conventional and digital radiography

    Marcia Regina Ramalho da Silva Bardauil, Cacio de Moura Netto e Abílio Albuquerque Maranhão de MouraBrazilian Oral Research2010

    This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP), and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA) and digital…

  3. Marginal adaptation of direct and indirect restorations through digital radiographs: literature review

    Claudia Sanae Akita Shimoide Muraoka, Gisele Lie Fukuoka, Emily Freitas da Silva e mais 1RGO - Revista Gaúcha de Odontologia2025

    ABSTRACT The precise marginal adaptation in dental restorations and dental prosthesis is one of the essential requirements for success and longevity of rehabilitating treatments. Since the presence of marginal cracks can lead to exposure of cementing agent to the oral environment, its consequent dissolution and micro…

  4. A comparative investigation of the quality of radiographs produced by portable handheld and fixed x-ray units

    Débora Costa Ruiz, Matheus L. Oliveira, Rocharles Cavalcante Fontenele e mais 2Brazilian Dental Journal2025

    Abstract To evaluate the impact of handheld portable intraoral diagnostic X-ray equipment on radiographic quality and to compare their radiographs with radiographs obtained using fixed intraoral X-ray equipment. For brightness, noise, and uniformity, radiographs of an acrylic block were obtained with two complementary…

  5. Evaluation of the reliability of measurements in cephalograms generated from cone beam computed tomography

    Maurício Barbosa Guerra da Silva, Bruno Cabús Gois e Eduardo Franzotti Sant'AnnaDental Press Journal of Orthodontics2013citado por 1 artigo

    OBJECTIVE: The purpose was to compare angular and linear measurements generated in digital cephalometric radiographs and cephalograms synthesized from three-dimensional images. METHODS: Twenty-six individuals (12 men and 14 women) with mean age of 26.3 years were selected. Digital cephalometric radiographs and CBCTs…

  6. Influence of the X-ray source and the digital image receptor on the expression of halo artefacts around dental implants

    Manuella Soussa Braga, Ana Maria de Almeida Ramos, Fernanda Coelho-Silva e mais 2Brazilian Journal of Oral Sciences2024

    Objectives To assess if different dental X-ray sources and receptors can improve the bone-to-implant interface image visualization by preventing halo artefact expression in terms of presence and magnitude. Methods 144 digital periapical radiographs of eight titanium implants installed in two human jaws were obtained…

  7. Radiopacity evaluation of Portland and MTA-based cements by digital radiographic system

    Alvaro Henrique Borges, Fabio Luiz Miranda Pedro, Alex Semanoff-Segundo e mais 3Journal of Applied Oral Science2011

    OBJECTIVE: The aim of the present study was to evaluate the radiopacity of Portland and MTA-based cements using the Digora TM digital radiographic system. MATERIAL AND METHODS: The performed tests followed specification number 57 from the American National Standard Institute/American Dental Association (2000) for…

  8. Efficacy of conventional and digital radiographic imaging methods for diagnosis of simulated external root resorption

    Vânia Portela Ditzel Westphalen, Ivaldo Gomes de Moraes e Fernando Henrique WestphalenJournal of Applied Oral Science2004citado por 4 artigos

    This in vitro study evaluated and compared the efficacy of conventional (Kodak F-speed (Insight), Kodak) and a digital (DRS Gnatus System, Gnatus) radiographic imaging for diagnosis of simulated external root resorption cavities. Human mandibles containing teeth were covered with bovine muscle slices in order to…

  9. Brightness and contrast adjustments influence proximal caries detection on handheld X-ray radiographs

    Débora Costa RUIZ, Marcyele Natane da Silva MORAIS, Hugo GAÊTA-ARAUJO e mais 3Brazilian Oral Research2026

    Abstract This study evaluated the influence of brightness and contrast adjustments on the diagnosis of proximal caries lesions in radiographs acquired with a handheld X-ray device. A complementary metal oxide semiconductor sensor (SnapShot, Instrumentarium Imaging, Milwaukee, WI, USA) and a handheld Eagle X-ray device…

  10. Automatic exposure compensation and subjective image enhancement in the radiographic diagnosis of caries

    Neiandro Santos GALVÃO, Eduarda Helena Leandro NASCIMENTO, Hugo GAÊTA-ARAUJO e mais 3Brazilian Oral Research2020

    Abstract This study aims to assess the influence of high-density material on the radiographic diagnosis of proximal caries in digital systems with automatic exposure compensation, and to evaluate the effect of subjective adjustment of brightness and contrast to undertake this diagnostic task. Twenty bitewing…

  11. Image quality in digital radiographic systems

    Solange Maria de Almeida, Ana Emília Figueiredo de Oliveira, Rívea Inês Ferreira e mais 1Brazilian Dental Journal2003citado por 4 artigos

    The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired…

  12. Influence of notebook computers screens and undergraduate level of dental students in the radiographic detection of carious lesions

    Rafaela Ramos Fernandes, Eduarda Alberti Bonadiman, Teresa Cristina Rangel Pereira e mais 2Brazilian Journal of Oral Sciences2024

    Aim To evaluate the influence of notebook computers screens and undergraduate level of dental students in the radiographic detection of carious lesions. Methods Bitewing digital radiographs were presented to 3rd and 5th year dental students in three different notebooks computers: Notebook 1 with anti-glare screen…

  13. Radiopacity of endodontic materials using two models for conversion to millimeters of aluminum

    Victor Manuel OCHOA-RODRÍGUEZ, Jorge Homero WILCHES-VISBAL, Barbara ROMA e mais 5Brazilian Oral Research2020citado por 1 artigo

    Abstract The aims of the present study were to compare conventional radiography, radiographs digitized with a scanner or photographic camera, and digital radiography, used to evaluate the radiopacity of endodontic materials, and to compare the accuracy of linear and quadratic models used to convert radiopacity values…

  14. Could the radiographic image quality be affected by the excessive use of the photostimulable phosphor plate?

    Débora Costa Ruiz, Amanda Farias Gomes, Rocharles Cavalcante Fontenele e mais 3Brazilian Dental Journal2023citado por 2 artigos

    Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five…

  15. DICOM file format has better radiographic image quality than other file formats: an objective study

    Murilo Miranda-Viana, Rocharles Cavalcante Fontenele, Fernanda Nogueira-Reis e mais 4Brazilian Dental Journal2023

    Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express…

  16. Evaluation of the microstructure, chemical composition, and image quality of different PSP receptors

    Gustavo Nascimento de SOUZA-PINTO, Yuri NEJAIM, Amanda Farias GOMES e mais 3Brazilian Oral Research2022citado por 1 artigo

    Abstract This study aimed to assess the microstructure, chemical composition, and image quality of different photostimulable phosphor plates (PSP). Four PSP systems, Express®, Digora®, VistaScan®, and Apixia,® were assessed. Five radiographs of a homogeneous acrylic phantom were obtained with the PSP of each system…

  17. Addition of zirconium oxide to Biodentine increases radiopacity and does not alter its physicochemical and biological properties

    Victor Manuel Ochoa-Rodríguez, Mario Tanomaru-Filho, Elisandra Marcia Rodrigues e mais 3Journal of Applied Oral Science2019citado por 6 artigos

    Abstract Objectives: To evaluate the radiopacity of Biodentine (BD) and BD associated with 15% calcium tungstate (BDCaWO4) or zirconium oxide (BDZrO2), by using conventional and digital radiography systems, and their physicochemical and biological properties. Materials and Methods: Radiopacity was evaluated by taking…

  18. Gray scale inversion in digital image for measurement of tooth length

    Matheus Lima Oliveira, Marcela Lacerda Vieira, Adriana Dibo Cruz e mais 2Brazilian Dental Journal2012

    The aim of this study was to assess the applicability of gray scale inversion in performing digital linear endodontic measurements. Standardized digital images were taken of 40 extracted human permanent single-rooted teeth with K-files size 15 placed at different lengths in the root canal, using the CDR Wireless®…

  19. Influence of a portable X-ray device in the diagnosis of proximal caries lesions

    Débora Costa RUIZ, Rocharles Cavalcante FONTENELE, Amanda FARIAS-GOMES e mais 4Brazilian Oral Research2025citado por 1 artigo

    Abstract This study aimed to evaluate the influence of a portable X-ray device on the diagnosis of proximal caries lesions. For that, radiographs of 40 human teeth with white spots or color changes in enamel and/or dentin were acquired using the Eagle X-ray portable device (Alliage, São Paulo, Brazil) set at 2.5 mA…

  20. Correlation of Fractal Dimension with Histomorphometry in Maxillary Sinus Lifting Using Autogenous Bone Graft

    Rafael Scaf de Molon, Wagner Nunes de Paula, Rubens Spin-Neto e mais 5Brazilian Dental Journal2015citado por 2 artigos

    The aim of this study was to determine the pattern of bone remodeling after maxillary sinus lifting in humans by means of fractal dimension (FD) and histomorphometric analysis. Therefore, the correlation between FD and the histomorphometric findings was evaluated. Sixteen patients with posterior edentulous maxilla…