acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Conventional brackets”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Stability comparison of two different dentoalveolar expansion treatment protocols

    Ezgi Atik e Tülin TanerDental Press Journal of Orthodontics2017

    ABSTRACT Objective: The aim of this study was to compare the longitudinal stability of the conventional straight-wire system after the use of a quad-helix appliance with Damon self-ligating system in patients with Class I malocclusion. Methods: 27 adolescent patients were evaluated at three different periods…

  2. Comparison of changes in the dental transverse and sagittal planes between patients treated with self-ligating and with conventional brackets

    Javier Moyano, Diana Montagut, Ramon Perera e mais 2Dental Press Journal of Orthodontics2020

    ABSTRACT Introduction: Several advantages have been established regarding the efficiency of self-ligating brackets (SL). In spite of some controversy surrounding this question in the literature, clinical results confirm that “arch development” requires fewer extractions. Objective: The objective of this study was to…

  3. Comparison of static friction with self-ligating, modified slot design and conventional brackets

    Raquel Morais Castro, Perrin Smith Neto, Martinho Campolina Rebello Horta e mais 2Journal of Applied Oral Science2013citado por 1 artigo

    OBJECTIVE: To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters. MATERIAL AND METHODS: The frictional forces were evaluated with three different types of metal…

  4. Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

    Maria Regina Guerra MONTEIRO, Licinio Esmeraldo da SILVA, Carlos Nelson ELIAS e mais 1Journal of Applied Oral Science2014citado por 1 artigo

    Objective: To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. Material and Methods: Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini…

  5. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires

    Vanessa Vieira Leite, Murilo Baena Lopes, Alcides Gonini Júnior e mais 3Dental Press Journal of Orthodontics2014citado por 1 artigo

    OBJECTIVE: To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. MATERIAL AND METHODS : Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a ligating wire 0.10-in was used to ligate…

  6. Microbial species associated with dental caries found in saliva and in situ after use of self-ligating and conventional brackets

    Ana Zilda Nazar BERGAMO, Mirian Aiko Nakane MATSUMOTO, Cássio do NASCIMENTO e mais 5Journal of Applied Oral Science2019

    Abstract Objectives Enamel demineralization is among the main topics of interest in the orthodontic field. Self-ligating brackets have been regarded as advantageous in this aspect. The aim of this study was to evaluate the break homeostasis in the oral environment and the levels of microorganisms associated with…

  7. Comparative study of torque expression among active and passive self-ligating and conventional brackets

    Érika Mendonça Fernandes Franco, Fabrício Pinelli Valarelli, João Batista Fernandes e mais 2Dental Press Journal of Orthodontics2015citado por 1 artigo

    Abstract Objective: The aim of this study was to compare torque expression in active and passive self-ligating and conventional brackets. Methods: A total of 300 segments of stainless steel wire 0.019 x 0.025-in and six different brands of brackets (Damon 3MX, Portia, In-Ovation R, Bioquick, Roth SLI and Roth Max)…

  8. Corrosion behavior of self-ligating and conventional metal brackets

    Lúcio Henrique Esmeraldo Gurgel Maia, Hibernon Lopes Filho, Antônio Carlos de Oliveira Ruellas e mais 2Dental Press Journal of Orthodontics2014

    Objective: To test the null hypothesis that the aging process in self-ligating brackets is not higher than in conventional brackets. Methods: Twenty-five conventional (GN-3M/Unitek; GE-GAC; VE-Aditek) and 25 self-ligating (SCs-3M/Unitek; INs-GAC; ECs-Aditek) metal brackets from three manufacturers (n = 150) were…

  9. Pain Perception and Rate of Canine Retraction Through Self-Ligating Brackets and Conventional Elastomeric Ligation System: A Split Mouth Study

    Irfan Qamruddin, Asma Gul Khan, Fatima Muhmmad Asif e mais 4Pesquisa Brasileira em Odontopediatria e Clínica Integrada2020

    Abstract Objective: To evaluate the rate of tooth movement and the pain perception via self-ligating (SL) and conventional elastomeric ligation brackets (CB) system. Material and Methods: This study has been conducted at the Orthodontic Department of Baqai Dental College, Baqai Medical University. The sample size of…

  10. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets

    Mauricio de Almeida Cardoso, Patrícia Pinto Saraiva, Liliana Ávila Maltagliati e mais 4Dental Press Journal of Orthodontics2015

    OBJECTIVE: The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. METHODS: Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight…

  11. Evaluation of friction produced by self-ligating, conventional and Barbosa Versatile brackets

    Jurandir Antonio BARBOSA, Carlos Nelson ELIAS e Roberta Tarkany BASTINGRevista de Odontologia da UNESP2016citado por 1 artigo

    Abstract Introduction The Barbosa Versatile bracket design may provide lower frictional force and greater sliding. However, no in vitro studies have shown its sliding mechanisms and frictional resistance, particularly in comparison with other self-ligating or conventional brackets. Objective To compare the frictional…

  12. Photoelastic analysis of stress generated by wires when conventional and self-ligating brackets are used: A pilot study

    Guilherme Caiado Sobral, Mário Vedovello Filho, Viviane Veroni Degan e mais 1Dental Press Journal of Orthodontics2014citado por 1 artigo

    OBJECTIVE: By means of a photoelastic model, this study analyzed the stress caused on conventional and self-ligating brackets with expanded arch wires. METHOD: Standard brackets were adhered to artificial teeth and a photoelastic model was prepared using the Interlandi 19/12 diagram as base. Successive activations…

  13. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Rodrigo Hitoshi Higa, Nayara Thiago Semenara, José Fernando Castanha Henriques e mais 3Dental Press Journal of Orthodontics2016

    ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and…

  14. Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions

    Sérgio Ricardo Jakob, Davison Matheus, Maria Cristina Jimenez-Pellegrin e mais 2Dental Press Journal of Orthodontics2014citado por 1 artigo

    OBJECTIVE: The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC), self-ligating ceramic (In-Ovation, Denstply GAC) and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC). METHODS: Five brackets were used for each model…

  15. Streptococcus mutans adherence to conventional and self-ligating brackets: an in vitro study

    Murilo Fernando Neuppmann FERES, Fernanda VICIONI-MARQUES, Fábio Lourenço ROMANO e mais 4Dental Press Journal of Orthodontics2021

    ABSTRACT Introduction: Although self-ligating brackets presumably provide better hygiene conditions, no consensus has been reached so far. Objective: Therefore, the objective of this study was to evaluate, in an in vitro experimental design, the adherence of Streptococcus mutans (SM) in self-ligating and conventional…

  16. Comparison surface characteristics and chemical composition of conventional metallic and Nickel-Free brackets

    Ricardo Lima SHINTCOVSK, Luegya Amorim Henriques KNOP, Luiz Gonzaga GANDINI Jr e mais 2Brazilian Oral Research2015

    This study aims at comparing conventional and nickel-free metal bracket surface characteristics with elemental composition by scanning electron microscopy (SEM), using energy dispersive spectroscopy (EDS). The sample consisted of 40 lower incisor brackets divided into four groups: ABZ = conventional brackets, Kirium…

  17. A comparative clinical study of the failure rate of orthodontic brackets bonded with two adhesive systems: conventional and self-etching primer (SEP)

    Gladys Cristina Dominguez, André Tortamano, Luiz Vicente de Moura Lopes e mais 2Dental Press Journal of Orthodontics2013citado por 1 artigo

    OBJECTIVE: This study compared the clinical performance of orthodontic brackets bonded with Transbond adhesive paste after two priming systems: a two-stage conventional system (acid etching + Transbond XT adhesive primer) and a singlestage self-etching primer (SEP) (Transbond Plus). METHODS: The sample comprised 480…

  18. Torque expression in conventional and self-ligating orthodontic brackets: An in vitro study

    Martha de Abreu Avila, José Guilherme Neves, Américo Bortolazzo Correr e mais 4Brazilian Dental Journal2026

    Abstract This study assessed torque expression at different angulations of conventional, interactive, and passive self-ligating brackets, with or without metal ligatures, and evaluated surface morphology and chemical composition (%). All brackets (Roth prescription, 0.022" x 0.028" slot) were fixed to round acrylic…

  19. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    Rogerio Amaral Tupinambá, Cristiane Aparecida de Assis Claro, Cristiane Aparecida Pereira e mais 2Dental Press Journal of Orthodontics2017citado por 1 artigo

    ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic…

  20. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    Manoela Fávaro Francisconi, Guilherme Janson, José Fernando Castanha Henriques e mais 1Journal of Applied Oral Science2016citado por 3 artigos

    ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual…