acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Contact lenses”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Clinical experience with adjustable scleral lenses

    César Lipener e Juliana RosaArquivos Brasileiros de Oftalmologia2023citado por 1 artigo

    ABSTRACT Purpose: The aim of this study was to evaluate the fitting process of a scleral lens that allows several parameter adjustments during trials and after the initial period of use. In addition, we verified which adjustments were needed and used the most, their indications, and how often these resources were…

  2. Bilateral Acanthamoeba ulcer in a user of disposable soft contact lenses: a tragic incident or a consequence of the aggressive policy of soft contact lens trading?

    Sidney Júlio de Faria e Sousa, Vanderson Glerian Dias e Luís Antonio Gorla MarcominiArquivos Brasileiros de Oftalmologia2008citado por 2 artigos

    This is the report of a case of bilateral Acanthamoeba keratitis in a 19-year-old woman who bought a pair of disposable soft contact lenses in a boutique. She wore this same pair of lenses for 3 months daily without the appropriate care. This led to bilateral corneal transplantation with cataract extraction and also…

  3. Scleral contact lenses in normal corneas: is it possible to improve visual performance?

    Cristina Cagliari e Paulo SchorRevista Brasileira de Oftalmologia2026

    ABSTRACT Objective: To analyze visual performance in digitally active volunteers using ScCLs. Methods: ScCLs were fit in seven participants and evaluated during four visits over 45 consecutive days. Reading speed tests were performed with MNREAD-P charts and texts developed by the Department of Speech Therapy of the…

  4. Contact lenses fitting after intracorneal ring segments implantation in keratoconus

    Luciane Bugmann Moreira, Ricardo Augustho Canto Bardal e Leila Roberta CrisigiovanniArquivos Brasileiros de Oftalmologia2013

    PURPOSE: Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS: Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with…

  5. Short-term visual performance of soft multifocal contact lenses for presbyopia

    Jennifer Sha, Ravi C. Bakaraju, Daniel Tilia e mais 6Arquivos Brasileiros de Oftalmologia2016citado por 1 artigo

    ABSTRACT Purpose: To compare visual acuity (VA), contrast sensitivity, stereopsis, and subjective visual performance of Acuvue® Oasys® for Presbyopia (AOP), Air Optix® Aqua Multifocal (AOMF), and Air Optix® Aqua Single Vision (AOSV) lenses in patients with presbyopia. Methods: A single-blinded crossover trial was…

  6. Corneoscleral contact lenses fitting on irregular corneas after laser-assisted in situ keratomileusis

    Juan Carlos Montalt, Esteban Porcar, Enrique España-Gregori e mais 1Arquivos Brasileiros de Oftalmologia2018

    ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic…

  7. Contact lenses as drug controlled release systems: a narrative review

    Helena Prior Filipe, José Henriques, Pedro Reis e mais 3Revista Brasileira de Oftalmologia2016

    ABSTRACT Topically applied therapy is the most common way to treat ocular diseases, however given the anatomical and physiological constraints of the eye, frequent dosing is required with possible repercussions in terms of patient compliance. Beyond refractive error correction, contact lenses (CLs) have, in the last…

  8. Visual rehabilitation using mini-scleral contact lenses after penetrating keratoplasty

    Guilherme Andrade do Nascimento Rocha, Patrícia Oliveira Braga Miziara, Ana Clara Vieira de Castro e mais 1Arquivos Brasileiros de Oftalmologia2017citado por 1 artigo

    ABSTRACT Purpose: To report the visual rehabilitation outcomes and complications of patients fitted with mini-scleral rigid gas-permeable (RGP) contact lenses (mini-SCLs) after penetrating keratoplasty. Methods: We retrospectively reviewed 27 eyes (21 patients) that were fitted with mini-SCLs between October 2013 and…

  9. Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology

    Letícia Helena Lunardi, Danielle Arroyo, Marcelo Vicente de Andrade Sobrinho e mais 2Arquivos Brasileiros de Oftalmologia2016

    ABSTRACT Purpose: Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical…

  10. Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

    Teresa Ferrer-Blasco, José J. Esteve-Taboada, Alberto Domínguez-Vicent e mais 4Arquivos Brasileiros de Oftalmologia2019

    ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by…

  11. Intraocular lenses and clinical treatment in paediatric cataract

    Camila Ribeiro Koch Pena, Priscilla Almeida Jorge e Newton Kara-JuniorRevista Brasileira de Oftalmologia2015citado por 1 artigo

    Pediatric cataract is the most common treatable cause of blindness in children. Prevalence, etiology and morphology vary with the socioeconomic development. The treatment goal is to reduce amblyopia, being difficult management especially in unilateral cases. The decision on aphakia or primary intraocular lens should…

  12. Longitudinal evaluation of corneal stability and tear film changes in first-time soft-contact lens wearers

    Neşe Arslan, Şule Barman Kakil, Bahar Aydoğdu e mais 1Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: Using advanced imaging techniques, this study aimed to evaluate corneal stability, epithelial remodeling, and tear film changes over a one-year period in first-time soft-contact lens wearers. Methods: A retrospective study was conducted on 100 eyes of 50 first-time daily soft-contact lens users aged…

  13. Efficacy of fitting HydroCone (Toris K) contact lenses for the visual rehabilitation of patients with posterior microphthalmos

    Gamze Ozturk Karabulut e Ferah OzcelikArquivos Brasileiros de Oftalmologia2023

    ABSTRACT Purpose: To evaluate the efficacy of soft HydroCone silicone hydrogel contact lenses in patients with posterior microphthalmos. Methods: The charts of 13 patients with posterior microphthalmos (26 eyes) who were fitted with soft HydroCone silicone hydrogel contact lenses were reviewed retrospectively. All the…

  14. The impact of various daily disposable contact lens materials on contrast sensitivity

    Burcu Nurözler Tabakci, Seda Duran Güler, Gül Varan e mais 2Arquivos Brasileiros de Oftalmologia2025

    ABSTRACT Purpose: This study aimed to compare the effects of three different daily disposable contact lens materials on contrast sensitivity. Methods: The participants were aged 18-45 years, with spherical equivalent refraction between -0.50 D and -6.00 D, astigmatism below 0.75 D, and best contact lens-corrected…

  15. Comparative analysis of biofilm formation by Candida albicans and Candida krusei in different types of contact lenses

    Laura Nagy Fritsch, Amanda Latercia Tranches Dias, Naiara Chaves Silva e mais 2Arquivos Brasileiros de Oftalmologia2022

    ABSTRACT Objective: To evaluate the Candida krusei and Candida albicans biofilm formation abilities on 5 different types of contact lenses and compare their metabolic activities and biomass. Methods: After biofilm formation by both the test species, their metabolic activity was assessed by the 2,3-bis…

  16. Effects of a new-generation hybrid contact lens on visual performance and vision-related quality of life in patients with keratoconus

    Sait Coskun Ozcan e Deniz Ozarslan OzcanArquivos Brasileiros de Oftalmologia2023

    ABSTRACT Purpose: The aim of this study was to evaluate the efficacy of a new-generation hybrid contact lens for improving visual outcomes and vision-related quality-of-life performance in patients with keratoconus who had intolerance or treatment failure of conventional correction methods such as the use of soft…

  17. Effects of two different contact lenses on ocular physiological parameters and tear function tests

    Adem Ugurlu, Turgay Ucak, Yucel Karakurt e mais 3Revista Brasileira de Oftalmologia2019

    Abstract Objective: To investigate the effects of two types of contact lenses made of two different types of silicone hydrogel material on ocular physiological parameters and tear function tests. Methods: The contact lenses with the appropriate diopters were supplied to the volunteering patients. The patients were…

  18. Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction

    Santiago García-Lázaro, Teresa Ferrer-Blasco, Hema Radhakrishnan e mais 2Arquivos Brasileiros de Oftalmologia2014

    Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an…

  19. Visual performance of scleral lenses and their impact on quality of life in patients with irregular corneas

    Dilay Ozek, Ozlem Evren Kemer e Pinar AltiaylikArquivos Brasileiros de Oftalmologia2018

    ABSTRACT Purpose: We aimed to evaluate the visual quality performance of scleral contact lenses in patients with keratoconus, pellucid marginal degeneration, and post-keratoplasty astigmatism, and their impact on quality of life. Methods: We included 40 patients (58 eyes) with keratoconus, pellucid marginal…

  20. Microbiological analysis of contact lens cases: impact of the hospital environment

    Vinicius Targa Villas Bôas, Gildásio Castello de Almeida Júnior, Margarete Teresa Gottardo de Almeida e mais 2Arquivos Brasileiros de Oftalmologia2018citado por 1 artigo

    ABSTRACT Purpose: The aim of this study was to analyze the bacterial and fungal microbiota found in contact lens cases among two groups of patients to correlate the data on the habits of contact lens users and to evaluate whether there is a difference in the culture results between users of ridged and nonridged…