acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Computer-Aided Design”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Removable partial denture metal framework manufactured by selective laser melting technology - A clinical report

    Joana Paulos Cabrita, Teresa Almeida Mendes, João Paulo Martins e mais 1Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2021citado por 1 artigo

    Abstract The selective laser melting technology is an additive digital method that permits producing metal frameworks for removable partial dentures. The existing literature has compared this technique with the classic technique in terms of precision, quality of fit, and function. This work describes a clinical case…

  2. Reliability of light microscopy and a computer-assisted replica measurement technique for evaluating the fit of dental copings

    Heike Rudolph, Silke Ostertag, Michael Ostertag e mais 3Journal of Applied Oral Science2018citado por 1 artigo

    Abstract The aim of this in vitro study was to assess the reliability of two measurement systems for evaluating the marginal and internal fit of dental copings. Material and Methods: Sixteen CAD/CAM titanium copings were produced for a prepared maxillary canine. To modify the CAD surface model using different…

  3. Measurement of the Occlusal Splint Wear using Computer-Aided Design Software: A Dental Technique

    José Jhenikártery Maia de Oliveira, Sabrina Barth de Andrade Luz, Fábio Ferreira de Souza Abbott Galvão e mais 3Pesquisa Brasileira em Odontopediatria e Clínica Integrada2026

    ABSTRACT Objective: To describe a technique used to measure wear on the surface of occlusal splints using dental Computer-Aided Design (CAD) software. Material and Methods: The technique employs intuitive CAD software (Exocad), which features innovative tools capable of providing qualitative analysis and quantitative…

  4. Screening of SIRT2 inhibitors from natural product databases using computer-aided drug design and molecular dynamics simulation

    Tianyi Liu, Hongli Yin, Xue Dong e mais 5Brazilian Journal of Pharmaceutical Sciences2025

    Abstract This study is committed to searching for inhibitors of deacetylase SIRT2 within the natural product database via computer-aided drug design techniques. A comprehensive computer-aided drug design platform has been successfully established by integrating various techniques such as drug-likeness screening…

  5. Computer-Aided Drug Design Studies in Association with in vitro Antileishmanial Tests for New Chalcones

    Gleice R. da Silva, Francisnaira S. Santos, Fernando F. Leite e mais 12Journal of the Brazilian Chemical Society2025

    In silico and in vitro tests can reveal promising anti-leishmania activity for natural products and their derivatives. The aim of this study was to investigate in silico the pharmacological activities of potential new chalcones and their leishmanicidal potential in vitro. The in silico study was carried out using the…

  6. PROTOCOLO DIGITAL PARA PROJETO CONCEITUAL E VALIDAÇÃO DE UMA ÓRTESE TORNOZELO-PÉ

    Rui Araújo Júnior e Patrícia Maria de Moraes Barros FucsActa Ortopédica Brasileira2025

    Abstract Objective: This original article aimed to develop a digital protocol for the conceptual design and validation of Ankle-Foot Orthoses (AFO) using 3D mapping technologies. Methods: A scanned model of the ankle-foot complex of a 12-year-old child with a drop foot was utilized, along with a generic AFO model from…

  7. Effect of clinical and laboratory techniques of cementation on the assessment of marginal and internal fit of prosthetic elements

    Carolina Chaves Pinto, Leonardo André Lins da Silva, Cristiana Almeida de Assis Licurci e mais 1Brazilian Journal of Oral Sciences2024

    Aim The aim of this in vitro study was to compare machine and manual cementation of prosthetic elements by measuring internal and marginal fits. Methods Eighteen anatomic prefabricated abutments were used to manufacture zirconia copings in the Ceramill (n=9) and Lava systems (n=9). The copings were cemented with a…

  8. Analog Electronic Circuit Synthesis Using Simulated Annealing and Geometric Circuit Evolution

    Leonardo Muttoni e Antônio C. P. VeigaJournal of Microwaves, Optoelectronics and Electromagnetic Applications2023

    Abstract This article presents the SANN-GCE algorithm, a spice simulation driven meta-heuristic to design general discrete analog electronic circuits automatically, both circuit topology and component sizing. We introduce an encoding scheme called Geometric Circuit Evolution (GCE) that works associated with the…

  9. A feature-based object-oriented expert system to model and support product design

    Nilson Luiz Maziero, João Carlos Espíndola Ferreira, Fernando Santana Pacheco e mais 1Journal of the Brazilian Society of Mechanical Sciences2000

    In this paper a computer program to model and support product design is presented. The product is represented through a hierarchical structure that allows the user to navigate across the product’s components, and it aims at facilitating each step of the detail design process. A graphical interface was also developed…

  10. Fracture strength and failure load of CAD/CAM fabricated endocrowns performed with different designs

    Fernanda Angeloni de Souza, Catarina Borges da Fonseca Cumerlato, Pedro Paulo Feltrin e mais 2Brazilian Journal of Oral Sciences2023citado por 1 artigo

    Aim Endocrown restorations are commonly used to rehabilitate endodontically treated posterior teeth and their use is well-founded in these cases. However, to date, there is little scientific evidence of their behavior in anterior teeth. The aim of this in vitro study was to evaluate the compressive strength of upper…

  11. Effect of cavity preparation design and ceramic type on the stress distribution, strain and fracture resistance of CAD/CAM onlays in molars

    Ana Luíza Serralha de Velloso VIANNA, Célio Jesus do PRADO, Aline Aredes BICALHO e mais 3Journal of Applied Oral Science2018citado por 1 artigo

    Abstract Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted…

  12. Impact of simulated toothbrushing and dentifrice abrasiveness on the surface roughness, gloss, and microhardness of CAD/CAM hybrid restorative materials

    Luana dos Santos Souza, Guilherme Schmitt de Andrade, Taciana Marco Ferraz Caneppele e mais 1Brazilian Journal of Oral Sciences2026

    Aim This study investigated the impact of toothpaste abrasiveness on the surface roughness, gloss, and microhardness of resin composite and CAD/CAM hybrid materials. Methods A 4x3 factorial design was utilized. The substrate was divided into 4 groups: Vita Enamic Hybrid Ceramic (VE), SHOFU Block HC Hybrid Ceramics…

  13. Effect of sensitivity and whitening toothpastes on roughness and microhardness of esthetic CAD-CAM restorative materials

    Gladys Juanita Teresa Purizaga Patiño, Elim Karine da Silva de Oliveira, Aline Cristina Batista Rodrigues Johann e mais 3Brazilian Journal of Oral Sciences2026

    Aim To assess the impact of brushing using 5 different toothpastes on the roughness and microhardness of CAD-CAM materials. Methods A total of 400 specimens (14 × 5 × 2.5 mm) were fabricated using four different materials: 2 resin composites (Lava Ultimate, LU; Cerasmart, CE), 1 polymer-infiltrated ceramic (Vita…

  14. Physical and color stability of PMMA provisional crowns made by conventional vs digital methods: in situ study

    Claudio Vinicius Dutra Perim Pellegrini, Nathalia Barcaro de Souza, Evla Gabriela de Sousa Ramos e mais 2Brazilian Journal of Oral Sciences2026

    Aim This cross sectional in situ study aimed to evaluate the physical properties and color stability of polymethylmethacrylate (PMMA)-based resins used in provisional crowns. Methods Twelve cubic specimens with 5mm edges of conventional self-, heat-polymerized acrylic resins, 3D-printed, and CAD-CAM milled PMMA resin…

  15. In vitro accuracy of digital versus conventional implant impressions for the all on four concept: a three dimensional analysis

    Monica Estefanía Tinajero Aroni, Raphael Ferreira de Souza Bezerra Araujo, Lucas Portela Oliveira e mais 3Brazilian Journal of Oral Sciences2026

    Aim To compare, in vitro, the three-dimensional accuracy of digital and conventional impression techniques for the All-on-Four concept. Methods A metal reference cast was fabricated to simulate an All-on-Four concept scenario. The cast was scanned using a contact scanner to serve as a control image. Subsequently, two…

  16. Fracture resistance of screw-retained premolar crowns fabricated with pressed lithium disilicate glass-ceramic and CAD-CAM translucent zirconia

    Bruno Kraft, Thiago de Almeida Prado Naves Carneiro, Rogério Goulart da Costa e mais 3Brazilian Journal of Oral Sciences2026

    CAD-CAM translucent zirconia materials have been marketed to fabricate fixed definitive prostheses. However, comparison of their fracture resistance to conventional pressed lithium disilicate glass-ceramic as screw-retained, implant-supported crowns is limited. Aim: This in vitro study evaluated the fracture…

  17. A novel technique for in vitro assessment of marginal fit in full-arch implant-supported prostheses

    Thaís BARBIN, Letícia Del Rio SILVA, Daniele Valente VELÔSO e mais 4Brazilian Oral Research2026

    Abstract This study proposes a novel no-screw (NS) technique for assessing marginal fit, comparing its performance with the established single-screw (SS) protocol, also known as the Sheffield test. Four implants and their corresponding abutments were placed in prototyped maxillae. Screw-retained implant-supported…

  18. Digital era in oral rehabilitation: a scoping review of trends and implications for clinical practice

    Adriana da Fonte Porto CARREIRO, Anne Kaline Claudino RIBEIRO, Gülce ÇAKMAK e mais 7Brazilian Oral Research2026

    Abstract This scoping review mapped the evidence on the clinical applicability and implications of digital workflows for fixed and removable full-arch rehabilitation in completely edentulous patients, focusing on workflow-related operational parameters and clinician-reported outcomes. This review was conducted in…

  19. Effect of cement space on 3D-printed fixed prostheses: an in vitro evaluation of accuracy and tensile strength

    Fernanda Clares Alves de Souza, Carolina Pirugini Noronha, Rodrigo Diniz Gomes e mais 4RGO - Revista Gaúcha de Odontologia2026

    ABSTRACT Objective: This in vitro study evaluated the internal adaptation and the influence of different internal cement space parameters on dimensional accuracy and tensile retention strength of 3D-printed provisional crowns. Methods: Three internal cement spaces (40 μm, 80 μm, and 120 μm) were digitally designed…

  20. Guided surgery with narrow implant: a case report using CAD/CAM technology

    Silvia Helena Maffei e Daniela Maffei BotegaRGO - Revista Gaúcha de Odontologia2026

    ABSTRACT The increasing need for precise and efficient rehabilitation of reduced edentulous spaces, such as narrow alveolar ridges, limited inter-root or mesiodistal dimensions, and decreased alveolar height, has driven the evolution of surgical techniques and implant systems. Narrow-diameter implants (≤3.5 mm) were…