acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Bone-implant interface”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of irrigation protocols on bone temperature control during guided implant surgery

    Theo Gualdi Alves, Leonardo Hoffmann de Barcellos, Hélio Radke Bittencourt e mais 3Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial2023

    Abstract Objectives: This experimental laboratory study aimed to compare the effect of four external irrigation protocols on bone tissue heating during guided implant drilling. Methods: Forty perforations were made in ten bovine rib specimens using customized surgical templates. Four experimental groups (n=10/group)…

  2. Oral implant osseointegration model in C57Bl/6 mice: microtomographic, histological, histomorphometric and molecular characterization

    Claudia Cristina Biguetti, Franco Cavalla, Elcia M. Silveira e mais 6Journal of Applied Oral Science2018citado por 1 artigo

    Abstract Despite the successful clinical application of titanium (Ti) as a biomaterial, the exact cellular and molecular mechanisms responsible for Ti osseointegration remains unclear, especially because of the limited methodological tools available in this field. Objective: In this study, we present a microscopic and…

  3. Osseointegration of Surface Coated and Surface Uncoated Titanium Dental Implants: A Systematic Review and Meta-Analysis

    Kiran Kumar Pandurangan, Anusha Kanniappan Sathiamurthy e Kaligotla Apoorva VasundharaPesquisa Brasileira em Odontopediatria e Clínica Integrada2026

    ABSTRACT Objective: To compare the osseointegration of surface-coated and uncoated titanium dental implants. Material and Methods: PubMed, Cochrane Library, SCOPUS, Web of Science, Google Scholar, and trial registries with no language or date of publication restrictions were searched on electronic databases. The risk…

  4. The effects of subcutaneous injection of nicotine on osseointegration of machined and anodized implants in rabbits

    Maria Salete Sandini Linden, Marcos Eugênio de Bittencourt, João Paulo De Carli e mais 5Acta Cirúrgica Brasileira2018citado por 1 artigo

    Abstract Purpose: To evaluate the influence of subcutaneous injection nicotine in osseointegration process on different implant surfaces. Methods: Twenty-two male rabbits were distributed into two groups according to the subcutaneous injections: (1) nicotine 3 mg/day/kg and (2) 0.9 % NaCI 3 mL/day/kg, three times a…

  5. Evaluation of hydrophilic surface osseointegration in low-density bone: Preclinical study in rabbits

    Gustavo da Col Santos Pinto, Isadora Aparecida Ribeiro dos Reis, Amanda de Carvalho Silva Leocádio e mais 4Brazilian Dental Journal2023

    Abstract The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted…

  6. Integration of heterologous bone matrix associated with polymethylmethacrylate in induced tibial bone defects. An experimental study in rabbits

    Silvio Henrique De Freitas, Alois Foltran Müller, Thaís Ribeiro Fadel e mais 7Acta Cirúrgica Brasileira2021

    ABSTRACT Purpose To analyze and compare the reactions at the interface between the composite, composed of fragmented heterologous mineralized bone matrix (MOMHF) and polymethylmethacrylate (PMMA), and the rabbit’s tibias, through macroscopic evaluation and scanning electron microscopy (SEM) in different periods…

  7. Bankart lesion repair: biomechanical and anatomical analysis of Mason-Allen and simple sutures in a swine model

    Ricardo Barreto Monteiro dos Santos, Cleber Maciel de Morais Prazeres, Ricardo Mertens Fittipaldi e mais 3Revista Brasileira de Ortopedia2018

    ABSTRACT Objective: To evaluate the labral height and pullout resistance after the repair of Bankart lesions in the glenohumeral joint of swine models, using double-loaded anchors with two suture configurations: simple and Mason-Allen. Methods: Ten swine shoulders were used, in which Bankart lesions were created. For…

  8. Does the implant-abutment interface interfere on marginal bone loss? A systematic review and meta-analysis

    Enéias Carpejani ROSA, Tatiana Miranda DELIBERADOR, Tuanny Carvalho de Lima do NASCIMENTO e mais 6Brazilian Oral Research2019

    Abstract The objective of this systematic review was to compare the conical internal connection (IC) with the external hexagonal connection (EH) on the occurrence of marginal bone loss (ΔMBL). Different databases were used to carry out the selection of the elected studies. The studies were judged according to the risk…

  9. Contact phenomena modeling in biological structures on the example of the implant-bone

    Marcin Zaczyk e Danuta Jasińska-ChoromańskaLatin American Journal of Solids and Structures2019

    Abstract The work presents modeling of interface phenomena in biological structures. Selected ways of numerical modeling of phenomena at the boundary of two materials by means of FEM methods are discussed. The work focuses on phenomena related to biological structures and their mutual interactions. Using an example of…

  10. Numerical study of effect of elastomeric stress absorbers on stress reduction in bone-dental implant interface

    Ghalem MEHDI, Abderrahmane BELARBI, Bensmaine MANSOURI e mais 1Journal of Applied Oral Science2015

    Objective This paper focused on optimal stress distribution in the mandibular bone surrounding a dental implant and is devoted to the development of a modified Osteoplant® implant type in order to minimize stress concentration in the bone-implant interface. Material and Methods This study investigated 0.4 mm thick…

  11. The Influence of Dietary Salt on the Osseointegration of Implants in Aging Rats

    Julio Baldisserotto, Dalva Maria Pereira Padilha e José Miguel AmenábarInternational Archives of Otorhinolaryngology2019

    Abstract Introduction The bone-implant interface has been studied extensively, but only few papers focused on the nutritional aspects that may affect bone quality, especially salt intake. Objective To study the osseointegration of implants in salt-loaded rats with low mineral bone content. Methods A total of 60…

  12. Effects of restraint stress and high-fat diet on osseointegration of titanium implants: an experimental study

    Serkan DUNDAR, Alihan BOZOGLAN, Ozgur BULMUS e mais 6Brazilian Oral Research2020

    Abstract This study aimed to investigate the effects of chronic restraint stress (RS) and a high-fat diet (HFD) on the osseointegration of titanium implants in a rat model. After the surgical insertion of titanium implants into the metaphysis of the tibial bone, the rats were randomly divided into four equal groups (n…

  13. Thermal analysis of the muscle-bone interface in test samples after the use of therapeutic ultrasound

    Cinthya Kelly Bastos Freire Nogueira, Luara Mirella Bitencourt Barbante, Karen de Almeida Coelho e mais 3Fisioterapia em Movimento2024

    Abstract Introduction Ultrasound used in diathermic therapies aims to achieve temperatures between 40 and 45 °C, since temperatures above 45 °C are known to cause tissue necrosis and burns. Many studies have been conducted to investigate the effect of therapeutic ultrasound in the presence of metallic implants, using…