acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Blood vessel prosthesis”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Surgarcane biopolymer patch in femoral artery angioplasty on dogs

    José Lamartine de Andrade Aguiar, Esdras Marques Lins, Silvio Romero de Barros Marques e mais 3Acta Cirúrgica Brasileira2007citado por 7 artigos

    PURPOSE: The objective of this study was to evaluate the use of the sugarcane biopolymer membrane in femoral artery patch angioplasty on dogs. METHODS: Eight dogs were submitted to bilateral femoral artery patch angioplasty with a sugarcane biopolymer membrane patch on one side and e-PTFE patch on the contralateral…

  2. Stent-Graft Relining in a Patient with Acute Aortic Aneurysm and a Completely Migrated Endograft

    Jayandiran Pillai, Ceyhan Yazicioglu, Mahad Omar e mais 1Brazilian Journal of Cardiovascular Surgery2017

    Abstract Stent-graft migration and type I endoleaks are associated with a higher rate of reintervention and increased mortality and morbidity. This article describes a patient presented with an infrarenal aortic stent-graft which had migrated into the aortic sac with loss of all aortic neck attachment. The acutely…

  3. Proximal endovascular blood flow shunt for thoracoabdominal aortic aneurism without total aortic clamping

    Gaudencio Espinosa, Rivaldo Tavares, Felippe Fonseca e mais 4Revista do Colégio Brasileiro de Cirurgiões2015citado por 1 artigo

    The authors present a surgical approach to type III and IV Crawford aneurysms that does not need total aortic clamping, which allows the more objective prevention of direct ischemic damage, as well as its exclusion by the endoprosthesis implantation, shunting the flow to the synthetic graft.

  4. Treatment For Infected Frozen Elephant Trunk Prosthesis Caused by Propionibacterium acnes: A Surgical Challenge

    Laura Varela Barca, Laura Esteban-Lucia, Marta Tomás-Mallebrera e mais 2Brazilian Journal of Cardiovascular Surgery2024

    ABSTRACT In this article, we present the case of a 47-year-old man who underwent Bentall-Bono procedure and frozen elephant trunk prosthesis implantation due to severe aortic regurgitation and aortic dilatation with a second-time endovascular stent-graft repair in descending aorta. Over eight years, a subacute graft…

  5. Open revascularization for chronic mesenteric ischemia in the endovascular era: a quaternary-center experience and management algorithm

    Bruno Pagnin Schmid, Vinícius Adorno Gonçalves, Lucas Marcelo Dias Freire e mais 2Jornal Vascular Brasileiro2024

    Abstract Background Chronic mesenteric ischemia (CMI) is a debilitating disease with a heavy burden on quality of life. Stenting of the superior mesenteric artery (SMA) is the first option for treatment, but there is a lack of consensus defining precise indications for open revascularization (OR). Objectives To…

  6. Acute Paraplegia Result from Spinal Ischemia Nine Years After Hybrid Total Arch Repair with Frozen Elephant Trunk: A Case Report

    Zeqin Xu, Zhu Tong, Jianming Guo e mais 3Brazilian Journal of Cardiovascular Surgery2023

    ABSTRACT Spinal cord ischemia due to decreased cord perfusion is a devastating complication in patients with thoracoabdominal dissection following frozen elephant trunk (FET) repair surgery. However, rare occurrence of spinal cord ischemia leading to paraplegia after long-term follow-up of FET repair has been…

  7. Tuberculous Aortic Aneurysm - A Review

    Abdulmajeed AltoijryBrazilian Journal of Cardiovascular Surgery2022

    ABSTRACT Introduction: Tuberculous aortic aneurysm (TBAA) is an exceedingly rare but severe manifestation of tuberculosis, with a high risk of sudden rupture of the aorta in absence of medical or surgical intervention. This review aimed to provide a detailed understanding of TBAA, including its associated…

  8. Direct and virtual measurements of abdominal aortic aneurysms: three-dimensional printed models

    Giovanna Ricarte Granja Gomes, Marcos Cordeiro D’Ornellas e Gustavo Nogara DottoRadiologia Brasileira2021

    Abstract Objective: To validate the use of a three-dimensional printing system for metric and volumetric analysis of the segments of an abdominal aortic aneurysm (AAA). Materials and Methods: In patients scheduled to undergo endovascular AAA repair, the computed tomography angiography (CTA) measurements obtained…

  9. Experimental comparative study of arterial implants made of silicone reinforced with polyester fabric and expanded polytetrafluoroethylene (PTFE) in rabbits aorta

    FERNANDA APPOLONIO ROCHA, LAILA MASSAD RIBAS, PAULO ISAO SASSAKI-NETO e mais 1Revista do Colégio Brasileiro de Cirurgiões2021

    ABSTRACT Objectives: the aim of this study was to compare the outcomes of a new silicone vascular prostheses with PTFE vascular prostheses, on a rabbit experimental model. Methods: forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE…

  10. Vascular access cannulation in hemodialysis patients: technical approach

    Manuel Carlos Martins Castro, Francisca Tokiko Yanagida Carlquist, Celina de Fátima Silva e mais 3Brazilian Journal of Nephrology2020citado por 1 artigo

    ABSTRACT Introduction: The vascular access cannulation technique varies among clinics, and guidelines on vascular access give little importance to cannulation techniques. The objective of this study was to evaluate the cannulation technique and to determine which factors are associated with each detail of the…

  11. Transcaval Access to the Abdominal Aorta: indications of Interest to Surgeons and a Comprehensive Literature Review

    Francisco S. Lozano Sánchez, Ignacio Cruz González, Roberto Salvador Calvo e mais 1Brazilian Journal of Cardiovascular Surgery2020

    Abstract We performed a review of the literature (until August 01, 2019) on the occasion of the first transcaval approach for transcatheter aortic valve implantation in our hospital. This review focuses mainly on the indications of this alternative access route to the aorta. It may be useful for vascular surgeons in…

  12. Comparison between Arch Zones in Modified Frozen Elephant Trunk Procedure for Complex Thoracic Aortic Diseases

    Mustafa Akbulut, Adnan Ak, Ozgur Arslan e mais 5Brazilian Journal of Cardiovascular Surgery2020citado por 1 artigo

    Abstract Introduction: The aim of this study is to compare postoperative outcomes and follow-up of two different modifications facilitating surgical technique of frozen elephant trunk (FET) procedure for complex thoracic aortic diseases - zone 0 (fixation with total arch debranching) and zone 3 (fixation with…

  13. Experimental implantation of an arterial substitute made of silicone reinforced with polyester fabric in rabbits

    Laila Massad Ribas, Inez Ohashi Torres, Fernanda Appolonio e mais 3Clinics2017citado por 1 artigo

    OBJECTIVES: The aim of this study was to analyze silicone tubes with an internal diameter of 4 mm as a possible material for vascular prostheses. METHODS: Grafts were implanted into the infrarenal aortas of 33 rabbits. Fluoroscopic examinations were performed within 150 days after surgical implantation. Sample grafts…

  14. Results of Castro Bernardes intraluminal ring in surgery for ascending aortic aneurysms and dissections

    Fernando Rotatori Novaes, Tulio Pinho Navarro, Rodrigo de Castro Bernardes e mais 4Brazilian Journal of Cardiovascular Surgery2013citado por 1 artigo

    OBJECTIVE: To demonstrate surgical results using Castro Bernardes intraluminal ring in ascending aorta surgery, instead of conventional suture. METHODS: 95 patients underwent ascending aorta surgery from December 2008 to April 2011 at Madre Tereza Hospital (Belo Horizonte, MG, Brazil), using Castro Bernardes…

  15. The effect of cardiopulmonary bypass in coronary artery bypass surgeries (on-pump versus off-pump) on erectile function and endothelium-derived nitric oxide levels

    Onder Canguven, Selami Albayrak, Ahmet Selimoglu e mais 3International braz j urol2011

    PURPOSE: To investigate the effects of on-pump and off-pump coronary artery bypass grafting (CABG) on the erectile function and endothelium-derived nitric oxide (eNO) levels. MATERIALS AND METHODS: Twenty-eight consecutive patients were randomized into two groups depending on use of cardiopulmonary bypass in CABG…

  16. Urological complication following aortoiliac graft: case report and review of the literature

    Leonardo Lima Borges, Fábio César Miranda Torricelli, Gustavo Xavier Ebaid e mais 2Sao Paulo Medical Journal2010

    CONTEXT: Ureteral stenosis and ureterohydronephrosis may be serious complications of aortoiliac or aortofemoral reconstructive surgery. CASE REPORT: A 62-year-old female patient presented with a six-month history of left lumbar pain. She was a smoker, and had mild chronic arterial hypertension and Takayasu arteritis…

  17. Endovascular repair of an aorto-iliac aneurysm succeeded by kidney transplantation

    Marcelo Bellini Dalio, Matheus Bredarioli, Edwaldo Edner Joviliano e mais 3Jornal Vascular Brasileiro2010

    We present the case of aorto-iliac aneurysm in a patient with chronic renal failure requiring dialysis who were treated with an endovascular stent graft and, later on, submitted to kidney transplantation. A 53-year-old male with renal failure requiring dialysis presented with an asymptomatic abdominal aorto-iliac…

  18. Aortic aneurysm surgery: problems and innovations

    Ralf Kolvenbach e Winston Bonetti YoshidaJornal Vascular Brasileiro2009

    A long way was traveled since the first surgery was performed for the treatment of abdominal aortic aneurysm. Throughout this time, several innovations have been created in order to reduce the invasiveness of the surgical procedures and to improve their safety and durability. This review discusses the major and recent…

  19. Abdominal aorta morphometric study for endovascular treatment of aortic aneurysms: comparison between spiral CT and angiography

    Gaudencio Espinosa, Edson Marchiori, Adalberto Pereira de Araújo e mais 2Brazilian Journal of Cardiovascular Surgery2002

    PURPOSE: To compare the computed tomography and angiography study of abdominal aortic aneurysms for posterior endograft implant. METHOD: From June 1997 to March 2001, 113 patients with abdominal aortic aneurysm were submitted to study of the aorto-iliac axis with abdominal spiral computed tomography and angiography…

  20. Lyophilized allografts without pre-treatment with glutaraldehyde are more suitable than cryopreserved allografts for pulmonary artery reconstruction

    J.R. Olmos-Zúãiga, R. Jasso-Victoria, N.E. Díaz-Martínez e mais 7Brazilian Journal of Medical and Biological Research2016

    Various methods are available for preservation of vascular grafts for pulmonary artery (PA) replacement. Lyophilization and cryopreservation reduce antigenicity and prevent thrombosis and calcification in vascular grafts, so both methods can be used to obtain vascular bioprostheses. We evaluated the hemodynamic…