acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Bárbara Juarez Amorim”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Interictal and postictal 18F-FDG PET/CT in epileptogenic zone localization

    Marcela Santos Carvalho, Marina Koutsodontis Machado Alvim, Elba Etchebehere e mais 5Radiologia Brasileira2022

    Abstract Objective: To evaluate the performance of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography ( 18F-FDG PET/CT) in localizing epileptogenic zones, comparing 18F-FDG injection performed in the traditional interictal period with that performed near the time of a seizure. Materials and…

  2. The ratio between the whole-body and primary tumor burden, measured on 18F-FDG PET/CT studies, as a prognostic indicator in advanced non-small cell lung cancer

    Felipe Renê Alves Oliveira, Allan de Oliveira Santos, Mariana da Cunha Lopes de Lima e mais 5Radiologia Brasileira2021citado por 1 artigo

    Abstract Objective: To determine whether the whole-body tumor burden, as quantified by 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT), is a prognostic indicator in advanced (stage III or IV) non-small cell lung cancer (NSCLC). Materials and Methods: This was a prospective…

  3. Update of the Brazilian Guideline on Nuclear Cardiology - 2020

    Luiz Eduardo Mastrocola, Barbara Juarez Amorim, João Vicente Vitola e mais 9Arquivos Brasileiros de Cardiologia2020citado por 7 artigos

    List of Abbreviations and AcronymsHED -11 C -meta-hydroxyephedrine labeled with Carbon-11 PIB-11 C -PET -pittsburgh B compound labeled with carbon-11 by PET imaging MIBG-123 I -metaiodobenzylguanidine labeled with iodine 123 13 NH 3 -ammonia labeled with Nitrogen-13 H 2 O-15 O -water labeled with Oxygen-15 FDG-18 F…

  4. Relapsed ovarian cancer - diagnosis using 18F-FDG PET/CT; 4.

    Fabio Peroba Esteves, Bárbara Juarez Amorim, Milena Martello e mais 4Revista da Associação Médica Brasileira2019

    The Guidelines Project, an initiative of the Brazilian Medical Association, aims to combine information from the medical field in order to standardize procedures to assist the reasoning and decision-making of doctors. The information provided through this project must be assessed and criticized by the physician…

  5. Cervical cancer - staging and restaging with 18F-FDG PET/CT

    Ana Emília T. Brito, Cristina Matushita, Fabio Esteves e mais 3Revista da Associação Médica Brasileira2019

    The Guidelines Project, an initiative of the Brazilian Medical Association, aims to combine information from the medical field in order to standardize producers to assist the reasoning and decision-making of doctors. The information provided through this project must be assessed and criticized by the physician…

  6. Guideline for Ventilation/Perfusion Scintigraphy

    Marcel Yanagihara Rigolon, Claudio Tinoco Mesquita e Bárbara Juarez AmorimInternational Journal of Cardiovascular Sciences2019

    Abstract This paper is about the Guideline for Ventilation / Perfusion Scintigraphy. It has been developed by the Brazilian Society of Nuclear Medicine to be a best practices guide used in Nuclear Medicine. Its function is to be an educational tool to help the Nuclear Medicine Services in Brazil to guarantee a quality…

  7. Influence of bladder fullness on the detection of urinary tract obstruction by dynamic renal scintigraphy

    Nathalia Novaes Cosenza, Fábio Lau, Mariana Cunha Lopes Lima e mais 4Radiologia Brasileira2017citado por 2 artigos

    Abstract Objective: To investigate the influence of bladder fullness on the diagnosis of urinary tract obstruction during dynamic renal scintigraphy with a diuretic stimulator. Materials and methods: We studied 82 kidneys in 82 patients submitted to dynamic renal scintigraphy with a diuretic stimulator. We compared…

  8. Functional electrical stimulation improves brain perfusion in cranial trauma patients

    Bárbara Juarez Amorim, Allan de Oliveira Santos, Telma Dagmar Oberg e mais 7Arquivos de Neuro-Psiquiatria2011

    OBJECTIVE: Demonstrate brain perfusion changes due to neuronal activation after functional electrical stimulation (FES). METHOD: It was studied 14 patients with hemiplegia who were submitted to a program with FES during fourteen weeks. Brain perfusion SPECT was performed before and after FES therapy. These patients…

  9. Brain SPECT in mesial temporal lobe epilepsy: comparison between visual analysis and SPM

    Bárbara Juarez Amorim, Celso Darío Ramos, Allan Oliveira dos Santos e mais 5Arquivos de Neuro-Psiquiatria2010

    OBJECTIVE: To compare the accuracy of SPM and visual analysis of brain SPECT in patients with mesial temporal lobe epilepsy (MTLE). METHOD: Interictal and ictal SPECTs of 22 patients with MTLE were performed. Visual analysis were performed in interictal (VISUAL(inter)) and ictal (VISUAL(ictal/inter)) studies. SPM…

  10. Brain hypoperfusion in adolescents dependent of multiple drugs

    Elba Cristina Sá de Camargo Etchebehere, Felipe Martins Oliveira, Bárbara Juarez Amorim e mais 2Arquivos de Neuro-Psiquiatria2010

    Brain SPECT imaging (BSI) with statistical parametric mapping (SPM) offers a clear and accurate vision of perfusion changes. OBJECTIVE: To study brain perfusion abnormalities in adolescents' dependent of multiple drugs. METHOD: Sixteen male patients (15.1±2.1 years) were submitted to 99mTc-HMPAO BSI with SPM. RESULTS…

  11. Low sensitivity of three-phase bone scintigraphy for the diagnosis of repetitive strain injury

    Bárbara Juarez Amorim, Elba Cristina Sá de Camargo Etchebehere, Graciella Dalla Torre e mais 6Sao Paulo Medical Journal2006

    CONTEXT AND OBJECTIVE: The diagnosis of repetitive strain injury (RSI) is subjective and solely based on clinical signs and physical examination. The aim of this paper was to assess the usefulness of three-phase bone scintigraphy (TPBS) in diagnosing RSI. DESIGN AND SETTING: Prospective study at the Division of…

  12. Statistical voxel-wise analysis of ictal SPECT reveals pattern of abnormal perfusion in patients with temporal lobe epilepsy

    Bárbara Juarez Amorim, Elba Cristina Sá de Camargo Etchebehere, Edwaldo Eduardo Camargo e mais 5Arquivos de Neuro-Psiquiatria2005citado por 3 artigos

    OBJECTIVE: To investigate the pattern of perfusion abnormalities in ictal and interictal brain perfusion SPECT images (BSI) from patients with temporal lobe epilepsy (TLE). METHOD: It was acquired interictal and ictal BSI from 24 patients with refractory TLE. BSIs were analyzed by visual inspection and statistical…