acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Americo CORRER”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of Ceramic Thickness on the Bond Strength to Resin-Luting Agents before and after Thermal Cycling

    Carolina Rodrigues de Souza, Ana Rosa Costa, Lincoln Pires Silva Borges e mais 5Brazilian Dental Journal2024

    Abstract This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained…

  2. Force Degradation of Elastomeric Chains after Storage Time and Mechanical Brushing

    Antonio Carlos da Silva Chaves-Filho, Ana Rosa Costa, Lincoln Pires Sousa Borges e mais 5Brazilian Dental Journal2021

    Abstract The purpose of this in vitro study was to evaluate the force decrease of different elastomeric chains after different times: initial, 10 minutes, 1 day, 28 days and after mechanical brushing. Twenty orthodontic elastomeric chains segments were utilized for each commercial brand. Initially, the elastomeric…

  3. CHX Stabilizes the Resin/demineralized Dentin Interface

    Ana Rosa Costa, Lucas Zago Naves, Franklin Garcia-Godoy e mais 4Brazilian Dental Journal2021

    Abstract The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) on microtensile bond strength (µTBS) between an adhesive system and under 3 dentin conditions. For that, this study evaluated the adhesive interface at initial, after 6 months and 1 year of storage. Forty-eight human third…

  4. Effect of etching time and light sources on the shear bond strength of metal brackets to ceramic cylinders

    Magda Regina PIAIA, Ana Rosa COSTA, Américo Bortolazzo CORRER e mais 3RGO - Revista Gaúcha de Odontologia2014

    OBJECTIVE: To evaluate the shear bond strength of brackets bonded to ceramic with Transbond XT resin, etching time intervals (1 and 2 minutes) and three Light sources (Xenon Plasma Arc, LED and Halogen Light ), with and without silane. METHODS: In total, 12 feldspathic ceramic cylinders (15 mm x 20 mm), etched with…

  5. Clinical evaluation of the failure rates of metallic brackets

    Fábio Lourenço Romano, Américo Bortolazzo Correr, Lourenço Correr-Sobrinho e mais 2Journal of Applied Oral Science2012citado por 4 artigos

    OBJECTIVES: The aim of this study was to evaluate in vivo the bonding of metallic orthodontic brackets with different adhesive systems. MATERIAL AND METHODS: Twenty patients (10.5-15.1 years old) who had sought corrective orthodontic treatment at a University Orthodontic Clinic were evaluated. Brackets were bonded…

  6. Inorganic particle analysis of dental impression elastomers

    Hugo Lemes Carlo, Rodrigo Borges Fonseca, Carlos José Soares e mais 3Brazilian Dental Journal2010citado por 3 artigos

    The aim of this study was to determine quantitatively and qualitatively the inorganic particle fraction of commercially available dental elastomers. The inorganic volumetric fraction of two addition silicones (Reprosil Putty/Fluid and Flexitime Easy Putty/Fluid), three condensation silicones (Clonage Putty/Fluid…

  7. Effect of different initial light intensity by the soft-start photoactivation on the bond strength and Knoop hardness of a dental composite

    Eduardo Dall'Magro, Mário Alexandre Coelho Sinhoreti, Américo Bortolazzo Correr e mais 3Brazilian Dental Journal2007citado por 5 artigos

    This study evaluated the bond strength (push-out method) and Knoop hardness of Z250 composite resin, photoactivated with XL 2500 curing unit, using different protocols: continuous mode (700mW/cm² for 20s) (CO); soft-start (50 mW/cm² for 5 s, followed by 700 mW/cm² for 15 s) (SS1); soft-start (100 mW/cm² for 5 s…

  8. Effect of veneering materials and curing methods on resin cement knoop hardness

    Rubens Nisie Tango, Mário Alexandre Coelho Sinhoreti, Américo Bortolazzo Correr e mais 2Brazilian Dental Journal2007citado por 3 artigos

    This study evaluated the Knoop hardness of Enforce resin cement activated by the either chemical/physical or physical mode, and light cured directly and through ceramic (HeraCeram) or composite resin (Artglass). Light curing were performed with either conventional halogen light (QTH; XL2500) for 40 s or xenon plasma…

  9. Light Activation and Thermocycling Methods on the Shear Bond Strength of Brackets Bonded to Porcelain Surfaces

    Gustavo Vallandro Lopes, Lourenço Correr-Sobrinho, Américo Bortolazzo Correr e mais 3Brazilian Dental Journal2020

    Abstract The present study was evaluated the effect of different light activation and thermocycling methods on the shear bond strength (SBS) and on the adhesive remnant index (ARI) of metal brackets bonded to feldspathic ceramic. Hundred metal brackets were bonded to 20 porcelain cylinders, divided into four groups…

  10. Physical-Mechanical Properties of Bulk Fill Composites Submitted to Biodegradation by Streptococcus mutans

    Jessica Rodrigues Camassari, Lourenço Correr-Sobrinho, Américo Bortolazzo Correr e mais 4Brazilian Dental Journal2020

    Abstract The aim of this study was to evaluate the Streptococcus mutans biofilm influence on the roughness (Ra), gloss (GU), surface hardness (KHN) and flexural strength (FS) of high viscosity bulk fill composites. Filtek Bulk Fill (FBF), Tetric N Ceram Bulk Fill (TNC), X-tra fil Bulk Fill (XF) and Filtek Z350 (FZ)…

  11. Effect of refrigeration on bond strength of self-etching adhesive systems

    Gilberto Antonio Borges, Ana Maria Spohr, Wildomar José de Oliveira e mais 3Brazilian Dental Journal2006citado por 1 artigo

    The purpose of this study was to investigate the tensile bond strength to dentin of three self-etching adhesive systems at refrigerated and room temperatures. Seventy-eight bovine incisors were embedded in self-cured acrylic resin, abraded on a water-cooled lathe and polished with 400- and 600-grit sandpapers to…

  12. Comparison of Silorane and Methacrylate-Based Composites on the Polymerization Heat Generated with Different Light-Curing Units and Dentin Thicknesses

    Ricardo Danil Guiraldo, Simonides Consani, Rafael Leonardo Xediek Consani e mais 4Brazilian Dental Journal2013citado por 1 artigo

    This study evaluated the temperature variation in the pulp chamber during photoactivation of two restorative composite resins (Filtek P90 silorane-based composite and Heliomolar methacrylate-based composite) with either a quartz-tungsten-halogen (QTH) or light-emitting diodes (LED) light-curing unit (LCU) and using…

  13. Effect of exposure time vs. irradiance on knoop hardness of dental composites

    Américo Bortolazzo Correr, Mário Alexandre Coelho Sinhoreti, Lourenço Correr-Sobrinho e mais 3Materials Research2006citado por 1 artigo

    A comparison was made of the hardness of Z250 and Esthet-X composites light cured with different light sources. Cavities (3 mm diameter x 6 mm deep) were prepared in 240 bovine incisors. The composite was bulk inserted and light-cured using halogen light, LED or xenon plasma arc (PAC) with different irradiances and…

  14. Effect of different photoactivation techniques on the bond strength of a dental composite

    Eduardo Dall'Magro, Américo Bortolazzo Correr, Ana Rosa Costa e mais 4Brazilian Dental Journal2010citado por 2 artigos

    Using the push-out test, this study evaluated the bond strength of the composite resin Z250 (3M/ESPE) photoactivated with the XL2500 (3M/ESPE) quartz-tungsten-halogen light-curing unit with different curing protocols: soft-start (150 mW/cm2 for 2 s (S2), 3 s (S3), 5 s (S5), 10 s (S10) or 15 s (S15), followed by 700…

  15. Torque expression in conventional and self-ligating orthodontic brackets: An in vitro study

    Martha de Abreu Avila, José Guilherme Neves, Américo Bortolazzo Correr e mais 4Brazilian Dental Journal2026

    Abstract This study assessed torque expression at different angulations of conventional, interactive, and passive self-ligating brackets, with or without metal ligatures, and evaluated surface morphology and chemical composition (%). All brackets (Roth prescription, 0.022" x 0.028" slot) were fixed to round acrylic…

  16. Influence of Thermal Cycles Number on Bond Strength of Metallic Brackets to Ceramic

    José Eliú Pereira Jurubeba, Ana Rosa Costa, Lourenço Correr-Sobrinho e mais 5Brazilian Dental Journal2017citado por 6 artigos

    Abstract The aim of this study was to evaluate the effect of different number of thermal cycles on the shear bond strength (SBS) of metallic orthodontic brackets bonded to feldspathic ceramic by a composite resin. Twenty-five ceramic cylinders were etched with 10% hydrofluoric acid for 60 s and received two layers of…

  17. Effect of Acid Etching, Silane and Thermal Cycling on the Bond Strength of Metallic Brackets to Ceramic

    Natália Regina Santos de Matos, Ana Rosa Costa, Heloísa Cristina Valdrighi e mais 4Brazilian Dental Journal2016citado por 3 artigos

    Abstract The aim of this study was to evaluate the effect of silanes, thermal cycling and acid etching on the shear bond strength (SBS) of metallic brackets to feldspathic ceramic. Feldspathic ceramic cylinders (Groups 1, 2, 5 and 6) were etched for 60 s with 10% hydrofluoric acid and Groups 3, 4, 7 and 8, without…

  18. Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions

    Guilherme B Guarda, Luciano S Gonçalves, Américo B Correr e mais 3Journal of Applied Oral Science2010citado por 5 artigos

    OBJECTIVES: The aim of this study was to investigate the bond strength of ceramic restorations luted using a self-adhesive resin cement (RelyX Unicem, 3M ESPE) under different dentin conditions. MATERIAL AND METHODS: In the experimental groups, ceramic restorations were luted to bovine incisors with RelyX Unicem under…

  19. Does the initial surface roughness of different CuNiTi wires affect the frictional resistance?

    Bernardo Brenner Pentagna, Viviane Veroni Degan, Ana Paula Terossi de Godoi e mais 3Brazilian Dental Journal2023

    Abstract This study aimed to assess and correlate initial surface roughness and frictional resistance of rectangular CuNiTi wires inserted in different self-ligating brackets. The sample consisted of 40 bracket-wire sets (rectangular CuNiTi wires of 0.017" x 0.025" and passive self-ligating brackets) divided into four…

  20. Resistência ao cisalhamento da colagem com compósitos utilizando potencializador de adesão

    Edivaldo de Morais, Fábio Lourenço Romano, Lourenço Correr Sobrinho e mais 2Dental Press Journal of Orthodontics2011

    OBJETIVO: avaliar a resistência ao cisalhamento dos compósitos Transbond XT e Concise Ortodôntico utilizando o potencializador de adesão Ortho Primer. MÉTODOS: a amostra consistiu de 90 incisivos bovinos divididos em seis grupos (n=15). Todos os dentes receberam profilaxia com pedra-pomes e condicionamento do esmalte…