acervo aberto · SciELO Brasil, Portugal e Espanha

709 mil artigos científicos, abertos e ligados entre si.

Cada obra mostra o resumo, a referência ABNT pronta, o que ela cita e quem no acervo a cita — para seguir a conversa de um artigo ao outro.

Obras para “Alfredo Júlio Fernandes Neto”

idioma
qualquerportuguêsinglêsespanhol
país
qualquerBrasilPortugalEspanha
tipo
tudoartigorevisãorelato de casocomunicação breve
anos
ordem
automáticarelevânciamais recentes
  1. Effect of Occlusal Splints on the Stress Distribution on the Temporomandibular Joint Disc

    Fabiane Maria Ferreira, Paulo Cézar Simamoto-Júnior, Carlos José Soares e mais 2Brazilian Dental Journal2017citado por 3 artigos

    Abstract Conservative approach, including occlusal splint therapy, is the first option to treat temporomandibular disorders (TMD), because of its reversibility. The present study analyzed the effect of the articular disc position and occlusal splints use on the stress distribution on this disc. A two-dimensional (2D)…

  2. Correlation between temporomandibular disorders, occlusal factors and oral parafunction in undergraduate students

    Fabiane Maria Ferreira, Paulo Cézar Simamoto-Júnior, Veridiana Resende Novais e mais 2Brazilian Journal of Oral Sciences2014

    Aim: To investigate the prevalence of temporomandibular disorders (TMD) in undergraduate students and to correlate its prevalence with occlusal factors and parafunctional habits. Methods: 201 undergraduate students were evaluated. The Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) was filled…

  3. Influence of different load application devices on fracture resistance of restored premolars

    Gisele Rodrigues da Silva, Natércia Rezende da Silva, Paulo Vinícius Soares e mais 3Brazilian Dental Journal2012citado por 2 artigos

    This in vitro study analyzed the effect of different load application devices on fracture resistance and failure mode of maxillary premolars restored with composite resin. Sixty human maxillary premolars received standardized mesio-occluso-distal cavity preparations and were restored with composite resin. The…

  4. Assessment in vitro of brushing on dental surface roughness alteration by laser interferometry

    Alessandra Miranda de Azevedo, Heitor Panzeri, Célio Jesus do Prado e mais 3Brazilian Oral Research2008citado por 2 artigos

    Noncarious cervical lesions (NCCLs) are considered to be of multifactorial origin, normally associated with inadequate brushing. This study assessed the influence in vitro of simulated brushing on NCCL formation. Fifteen human premolars were submitted to brushing in the cementoenamel junction region, using hard-…

  5. Temporomandibular disorder and anxiety, quality of sleep, and quality of life in nursing professionals

    Larissa Kattiney OLIVEIRA, Guilherme de Araújo ALMEIDA, Éverton Ribeiro LELIS e mais 2Brazilian Oral Research2015citado por 5 artigos

    To evaluate the association between temporomandibular disorder (TMD) and anxiety, quality of sleep, and quality of life in nursing professionals at theHospital de Clínicas de Uberlândiaof theUniversidade Federal de Uberlândia – HCU-UFU (Medical University Hospital of the Federal University of Uberlândia), four…

  6. Identification of occlusal prematurity by clinical examination and cone-beam computed tomography

    Naila Aparecida de Godoi Machado, João César Guimarães Henriques, Éverton Ribeiro Lelis e mais 3Brazilian Dental Journal2013

    The aim of this study was to evaluate the ability to identify occlusal prematurity by images from paraxial slices of cone-beam computed tomography (CBCT). For such purpose, a pilot study was performed in which 16 asymptomatic young patients were subjected to a clinical examination, including a careful occlusal…

  7. Soy milk as a storage medium to preserve human fibroblast cell viability: an in vitro study

    Camilla Christian Gomes Moura, Priscilla Barbosa Ferreira Soares, Manuella Verdinelli de Paula Reis e mais 2Brazilian Dental Journal2012citado por 2 artigos

    Soy milk (SM) is widely consumed worldwide as a substitute for cow milk. It is a source of vitamins, carbohydrates and sugars, but its capacity to preserve cell viability has not been evaluated. The purpose of the present study was to investigate the efficacy of SM to maintain the viability of human fibroblasts at…

  8. Effect of plasma welding parameters on the flexural strength of ti-6al-4v alloy

    João Paulo Lyra e Silva, Alfredo Júlio Fernandes Neto, Luís Henrique Araújo Raposo e mais 4Brazilian Dental Journal2012citado por 1 artigo

    The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the…

  9. Cone-beam tomography assessment of condylar position discrepancy between centric relation and maximal intercuspation

    João César Guimarães Henriques, Alfredo Júlio Fernandes Neto, Guilherme de Araújo Almeida e mais 2Brazilian Oral Research2012citado por 1 artigo

    The magnitude of occasional discrepancies between the centric relation and maximal intercuspation positions remains a controversial subject. This study quantitatively evaluated the possible discrepancies in the condyle/mandibular fossa relationship between these positions using cone-beam computed tomography. Twenty…

  10. Polytetrafluorethylene added to acrylic resins: mechanical properties

    Fabiana Gouveia Straioto, Antonio Pedro Ricomini Filho, Alfredo Júlio Fernandes Neto e mais 1Brazilian Dental Journal2010citado por 2 artigos

    The addition of different polymers, such as polytetrafluorethylene (PTFE), to denture base resins could be an option to modify acrylic resin mechanical properties. This study evaluated the surface hardness, impact and flexural strength, flexural modulus and peak load of 2 acrylic resins, one subjected to a long and…

  11. Effect of periodontal therapies on indirect restoration: a scanning electron microscopic analysis

    Priscilla Barbosa Ferreira Soares, Denildo Magalhães, Alfredo Júlio Fernandes Neto e mais 3Brazilian Dental Journal2010citado por 1 artigo

    The aim of this study was to evaluate the influence of different periodontal therapies on the integrity of indirect restorations by scanning electron microscopy (SEM). Sixty single-rooted bovine teeth were selected and randomly assigned to 12 groups. Inlay cavities were prepared in the cervical region on the center of…

  12. Postural evaluation of patients with temporomandibular disorders under use of occlusal splints

    Paulinne Junqueira Silva Andresen Strini, Naila Aparecida de Godoi Machado, Marília Cavalheri Gorreri e mais 3Journal of Applied Oral Science2009citado por 4 artigos

    OBJECTIVES: Alterations in the temporomandibular complex can reflect in adaptations of the individual's entire muscular system, intervening with the head position and scapular waist, developing postural alterations and modifying all corporal biomechanics. The aim of this study was to evaluate the head position (HP)…

  13. Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)

    Amanda de Freitas Ferreira, João César Guimarães Henriques, Guilherme Araújo Almeida e mais 3Journal of Applied Oral Science2009

    This research consisted of a quantitative assessment, and aimed to measure the possible discrepancies between the maxillomandibular positions for centric relation (CR) and maximum intercuspation (MI), using computed tomography volumetric cone beam (cone beam method). The sample of the study consisted of 10…

  14. Relation between implant/abutment vertical misfit and torque loss of abutment screws

    Gustavo Augusto Seabra Barbosa, Sérgio Rocha Bernardes, Flávio Domingues das Neves e mais 3Brazilian Dental Journal2008citado por 6 artigos

    This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four…

  15. Influence of method and period of storage on the microtensile bond strength of indirect composite resin restorations to dentine

    Fernanda Ribeiro Santana, Janaína Carla Pereira, Cristina Alves Pereira e mais 2Brazilian Oral Research2008citado por 3 artigos

    This study evaluated the influence of the method and period of storage on the adhesive bond strength of indirect composite resin to bovine dentin. Ninety bovine incisors were stored in three different solutions: 0.2% thymol, 10% formalin, and 0.2% sodium azide, during 3 periods of storage: 7 days, 30 days and 6…

  16. Prosthetic laboratory influence on the vertical misfit at the implant/UCLA abutment interface

    Gustavo Augusto Seabra Barbosa, Paulo Cézar Simamoto Júnior, Alfredo Júlio Fernandes Neto e mais 2Brazilian Dental Journal2007citado por 9 artigos

    An inadequate fit at the abutment/implant interface can generate mechanical and biological problems. The laboratorial stages could induce misfit in such interface when the castable UCLA abutment type is used. The purpose of this study was to comparatively evaluate the performance of three prosthetic laboratories (Labs…

  17. Dental wear caused by association between bruxism and gastroesophageal reflux disease: a rehabilitation report

    Naila Aparecida de Godoi Machado, Rodrigo Borges Fonseca, Carolina Assaf Branco e mais 3Journal of Applied Oral Science2007citado por 1 artigo

    Bruxism is a pathological activity of the stomatognathic system that involves tooth grinding and clenching during parafunctional jaw movements. Clinical signs of bruxism are mostly related to dental wear and muscular and joint discomforts, but a large number of etiological factors can be listed, as local, systemic…

  18. Bond strength of three dental porcelains to Ni-Cr and Co-Cr-Ti alloys

    Alfredo Julio Fernandes Neto, Heitor Panzeri, Flavio Domingues Neves e mais 2Brazilian Dental Journal2006

    Ceramometal bond strength has played an important role for the replacement of gold alloys by nickel-chromium alloys in dentistry. This study evaluated the metal/porcelain bond strength of three ceramic systems (Vita VMK 88, Williams and Duceram) associated with three nickel-chromium alloys (Durabond, Lite Cast B and…

  19. Shear bond strength of dental porcelains to nickel-chromium alloys

    Ricardo Alves do Prado, Heitor Panzeri, Alfredo Julio Fernandes Neto e mais 3Brazilian Dental Journal2005citado por 2 artigos

    The continuous technological advance and increasing availability of new base metal alloys and ceramic systems in the market, coupled to the demands of daily clinical practice, have made the constant evaluation of the bond strength of metal/porcelain combinations necessary. This study evaluated the metal/porcelain…

  20. Evaluation of intracanal post removal using ultrasound

    Marlete Ribeiro da Silva, João Carlos Gabrielli Biffi, Adérito Soares da Mota e mais 2Brazilian Dental Journal2004citado por 3 artigos

    The aim of this study was to determine the effect of ultrasonic vibration on the force necessary to remove pre-fabricated and anatomic and cast posts. Two hundred and forty teeth were divided into two groups. In group I, a 0.8-mm metallic pre-fabricated post, Unimetric-Maillefer, was utilized; in group II, cast…