Iberoamerican Journal of Medicine2022

Bioresorbable scaffolds: current concepts and future technology

Debabrata Dash e Shahid A. Merchant

artigo de revisão · em inglês

cita 67 obras

resumo

Abstract The introduction of the drug-eluting (DES) stent to percutaneous coronary intervention (PCI) had a significant impact on patient management of coronary artery disease and has been called the "third revolution" in interventional cardiology after the first 2 revolutions of balloon angioplasty and bare-metal stents. The promise of adaptive remodeling, restoration of vasomotion, late luminal enlargement, and retained potential for future coronary artery bypass grafting at the site of previous PCI has been the driving force behind bioresorbable stent/scaffold (BRS) technology development. Moreover, because of the inherent risk of late and very late stent thrombosis, BRS potentially offers a solution and recent years have seen heightened interest, hype, and hope. In this current review, we are aiming to shed light on strength and weakness of various BRS including the future perspective.

como citar · ABNT NBR 6023

DASH, Debabrata; MERCHANT, Shahid A. Bioresorbable scaffolds: current concepts and future technology. Iberoamerican Journal of Medicine, 2022. DOI: 10.53986/IBJM.2022.0034.

Referências

67 obras citadas

  1. 1T Palmerini, G Biondi-Zoccai, D Della Riva e mais 3. Stent thrombosis with drug-eluting stents: is the paradigm shifting?. J Am Coll Cardiol, 2013quem mais cita →
  2. 2H Jinnouchi, S Torii, A Sakamoto e mais 3. Fully bioresorbable vascular scaffolds: lessons learned and future directions. Nat Rev Cardiol, 2019quem mais cita →
  3. 3R Waksman. Promise and challenges of bioabsorbable stents. Catheter Cardiovasc Interv, 2007quem mais cita →
  4. 4B Tesfamariam. Bioresorbable vascular scaffolds: Biodegradation, drug delivery and vascular remodeling. Pharmacol Res, 2016quem mais cita →
  5. 5JJ Wykrzykowska, RP Kraak, SH Hofma e mais 3. Bioresorbable Scaffolds versus Metallic Stents in Routine PCI. N Engl J Med, 2017quem mais cita →
  6. 6PW Serruys, B Chevalier, D Dudek e mais 3. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial. Lancet, 2015quem mais cita →
  7. 7C Hehrlein, B Schorch, N Kress e mais 3. Zn-alloy provides a novel platform for mechanically stable bioresorbable vascular stents. PLoS One, 2019quem mais cita →
  8. 8Y Onuma e PW Serruys. Bioresorbable scaffold: the advent of a new era in percutaneous coronary and peripheral revascularization?. Circulation, 2011quem mais cita →
  9. 9C Simon, JC Palmaz e EA Sprague. Influence of topography on endothelialization of stents: clues for new designs. J Long Term Eff Med Implants, 2000quem mais cita →
  10. 10PW Serruys, B Chevalier, Y Sotomi e mais 3. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial. Lancet, 2016quem mais cita →
  11. 11RA Byrne, GG Stefanini, D Capodanno e mais 3. Report of an ESC-EAPCI Task Force on the evaluation and use of bioresorbable scaffolds for percutaneous coronary intervention: executive summary. Eur Heart J, 2018quem mais cita →
  12. 12DJ Kereiakes, SG Ellis, DC Metzger e mais 3. Clinical Outcomes Before and After Complete Everolimus-Eluting Bioresorbable Scaffold Resorption: Five-Year Follow-Up From the ABSORB III Trial. Circulation, 2019quem mais cita →
  13. 13B Xu, Y Yang, Y Han e mais 3. Comparison of everolimus-eluting bioresorbable vascular scaffolds and metallic stents: three-year clinical outcomes from the ABSORB China randomised trial. EuroIntervention, 2018quem mais cita →
  14. 14K Okada, Y Honda, H Kitahara e mais 3. Bioresorbable Scaffold for Treatment of Coronary Artery Lesions: Intravascular Ultrasound Results From the ABSORB Japan Trial. JACC Cardiovasc Interv, 2018quem mais cita →
  15. 15Y Katagiri, Y Onuma, T Asano e mais 3. Three-year follow-up of the randomised comparison between an everolimus-eluting bioresorbable scaffold and a durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction (TROFI II trial). EuroIntervention, 2018quem mais cita →
  16. 16D Arroyo, G Gendre, S Schukraft e mais 3. Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds: Two-year clinical outcomes of the EVERBIO II trial. Int J Cardiol, 2017quem mais cita →
  17. 17RA Byrne, GG Stefanini, D Capodanno e mais 3. Report of an ESC-EAPCI Task Force on the evaluation and use of bioresorbable scaffolds for percutaneous coronary intervention: executive summary. EuroIntervention, 2018quem mais cita →
  18. 18HM Nef, J Wiebe, N Foin e mais 3. A new novolimus-eluting bioresorbable coronary scaffold: Present status and future clinical perspectives. Int J Cardiol, 2017quem mais cita →
  19. 19J Wiebe, O Dörr, H Ilstad e mais 3. Everolimus- Versus Novolimus-Eluting Bioresorbable Scaffolds for the Treatment of Coronary Artery Disease: A Matched Comparison. JACC Cardiovasc Interv, 2017quem mais cita →
  20. 20G Barreira, JR Costa JR, R Costa e mais 3. Serial intravascular ultrasound evaluation of the DESolve™ novolimus-eluting bioresorbable coronary scaffold system. Catheter Cardiovasc Interv, 2018quem mais cita →
1–20 de 67 obras citadas

Quem cita esta obra

nenhum artigo do acervo cita esta obra — ainda

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações