Abstract Introduction Polymer optical fibers (POF) are lightweight, present high elastic strain limits, fracture toughness, flexibility in bend, and are not influenced by electromagnetic fields. These characteristics enable the application of POF as curvature sensor and can overcome the limitations of the conventional technologies, especially for wearable and soft robotics devices. Nevertheless, POF based curvature sensors can suffer from environmental and light source power deviations. This paper presents a compensation technique for the environmental and light source power deviations in a POF curvature sensor. Methods The curvature sensor was submitted to variations of temperature, humidity and light source power to characterize the sensor response and evaluate the proposed compensation technique. In addition, tests with the simultaneous variation of the angle and light source power variation were performed. Results Results show that temperature and humidity effects do not lead to significative errors on the sensor measurement for wearable devices application, where a hardware-based compact and portable compensation technique of the light source deviation is applied. Moreover, the sensor with the compensation technique developed is compared with a potentiometer for dynamic measurements and the root-mean-square error of about 1° is obtained, which is lower than sensors based on similar operation principle presented in the literature and some commercially available devices. Conclusions The compensation technique proposed was able to compensate power deviations applied and resulted in a sensor with low errors with the additional advantages of compactness and low-cost, which enable its application as wearable sensors and on the instrumentation of wearable robots.

como citar · ABNT NBR 6023

LEAL-JUNIOR, Arnaldo Gomes; FRIZERA, Anselmo; PONTES, Maria José. Compensation technique for environmental and light source power variations applied in a polymer optical fiber curvature sensor for wearable devices. Research on Biomedical Engineering, 2018. DOI: 10.1590/2446-4740.04917.

Referências

33 obras citadas

  1. 1PF Antunes, H Varum e PS Andre. Intensity-encoded polymer optical fiber accelerometer. IEEE Sens J, 2013quem mais cita →
  2. 2L Bilro, JG Oliveira, JL Pinto e mais 1. A reliable low-cost wireless and wearable gait monitoring system based on a plastic optical fibre sensor. Meas Sci Technol, 2011quem mais cita →
  3. 3L Bilro, N Alberto, JL Pinto e mais 1. Optical sensors based on plastic fibers. Sensors (Basel), 2012quem mais cita →
  4. 4SAAN Bolink, H Naisas, R Senden e mais 4. Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: comparison with an optoelectronic motion capture system. Med Eng Phys, 2016quem mais cita →
  5. 5AA Braidot, CC Cifuentes, A Frizera No e mais 2. ZigBee wearable densor development for upper limb robotics rehabilitation. IEEE Lat Am Trans., 2013quem mais cita →
  6. 6JT Coulthard, TT Treen, AR Oates e mais 1. Evaluation of an inertial sensor system for analysis of timed-up-and-go under dual-task demands. Gait Posture, 2015quem mais cita →
  7. 7H Dejnabadi, BM Jolles e K Aminian. A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes. IEEE Trans Biomed Eng, 2005quem mais cita →
  8. 8M Donno, E Palange, F Di Nicola e mais 2. A new flexible optical fiber goniometer for dynamic angular measurements: Application to human joint movement monitoring. Instrumentation., 2008quem mais cita →
  9. 9LE Dunne, P Walsh, S Hermann e mais 2. Wearable monitoring of seated spinal posture. IEEE Trans Biomed Circuits Syst, 2008quem mais cita →
  10. 10M El-Gohary e J McNames. Shoulder and elbow joint angle tracking with inertial sensors. IEEE Trans Biomed Eng, 2012quem mais cita →
  11. 11D Holland, C Abah, M Velasco-Enriquez e mais 4. The soft robotics toolkit. IEEE Robot Autom Mag, 2017quem mais cita →
  12. 12K Kirtley. Clinical gait analysis: theory and practice. 2006quem mais cita →
  13. 13AG Leal-Junior, A Frizera-Neto e MJ Pontes. Analytical model for a polymer optical fiber under dynamic bending. Opt Laser Technol, 2017quem mais cita →
  14. 14AG Leal-Junior, A Frizera-Neto, MJ Pontes e mais 1. Hysteresis compensation technique applied to polymer optical fiber curvature sensor for lower limb exoskeletons. Meas Sci Technol, 2017quem mais cita →
  15. 15AG Leal-Junior, A Frizera-Neto e MJ Pontes. Sensitive zone parameters and curvature radius evaluation for polymer optical fiber curvature sensors. Opt Laser Technol, 2018quem mais cita →
  16. 16R Liu, F Zhuang, Z Yanzheng e mais 2. Operation principle of a bend enhanced curvature optical fiber sensor. IEEE Int Conf Intell Robot Syst, 2006quem mais cita →
  17. 17CA Marques, GD Peng e DJ Webb. Highly sensitive liquid level monitoring system utilizing polymer fiber Bragg gratings. Opt Express, 2015quem mais cita →
  18. 18AT Moraleda, CV García, JZ Zaballa e mais 1. A temperature sensor based on a polymer optical fiber macro-bend. Sensors (Basel), 2013quem mais cita →
  19. 19JC Moreno, L Bueno e JL Pons. Wearable robot technologies. Wearable robots: biomechatronic exoskeletons, 2008quem mais cita →
  20. 20K Peters. Polymer optical fiber sensors - a review. Smart Mater Struct, 2011quem mais cita →