Research on Biomedical Engineering2017
Realistic deformable 3D numeric phantom for transcutaneous ultrasound
Fernando Mitsuyama Cardoso, Matheus Cardoso Moraes e Sergio Shiguemi Furuie
em inglês
resumo
Abstract Introduction Numerical phantoms are important tools to design, calibrate and evaluate several methods in various image-processing applications, such as echocardiography and mammography. We present a framework for creating ultrasound numerical deformable phantoms based on Finite Element Method (FEM), Linear Isomorphism and Field II. The proposed method considers that the scatterers map is a property of the tissue; therefore, the scatterers should move according to the tissue strain. Methods First, a volume representing the target tissue is loaded. Second, parameter values, such as Young’s Modulus, scatterers density, attenuation and scattering amplitudes are inserted for each different regions of the phantom. Then, other parameters related to the ultrasound equipment, such as ultrasound frequency and number of transducer elements, are also defined in order to perform the ultrasound acquisition using Field II. Third, the size and position of the transducer and the pressures that are applied against the tissue are defined. Subsequently, FEM is executed and deformation is computed. Next, 3D linear isomorphism is performed to displace the scatterers according to the deformation. Finally, Field II is carried out to generate the non-deformed and deformed ultrasound data. Results The framework is evaluated by comparing strain values obtained the numerical simulation and from the physical phantom from CIRS. The mean difference between both phantoms is lesser than 10%. Conclusion The acoustic and deformation outcomes are similar to those obtained using a physical phantom. This framework led to a tool, which is available online and free of charges for educational and research purposes.
como citar · ABNT NBR 6023
CARDOSO, Fernando Mitsuyama; MORAES, Matheus Cardoso; FURUIE, Sergio Shiguemi. Realistic deformable 3D numeric phantom for transcutaneous ultrasound. Research on Biomedical Engineering, 2017. DOI: 10.1590/2446-4740.05616.
Referências
31 obras citadas
- 1H Anton e C Rorres. Elementary linear algebra: applications version. 2005quem mais cita →
- 2RA Baldewsing, CL de Korte, JA Schaar e mais 2. A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries. Ultrasound in Medicine & Biology, 2004quem mais cita →
- 3SN Bhatti e M Sridhar-Keralapura. A novel breast software phantom for biomechanical modeling of elastography. Medical Physics, 2012quem mais cita →
- 4JE Browne, KV Ramnarine, AJ Watson e mais 1. Assessment of the acoustic properties of common tissue-mimicking test phantoms. Ultrasound in Medicine & Biology, 2003quem mais cita →
- 5RO Bude e RS Adler. An easily made, low-cost, tissue-like ultrasound phantom material. Journal of Clinical Ultrasound, 1995quem mais cita →
- 6FM Cardoso, MC Moraes e SS Furuie. A framework to create realistic IVUS phantoms for different intraluminal pressures. 2011quem mais cita →
- 7FM Cardoso, MC Moraes e SS Furuie. Realistic IVUS image generation in different intraluminal pressures. Ultrasound in Medicine & Biology, 2012quem mais cita →
- 8EI Céspedes, J Ophir, H Ponnekanti e mais 1. Elastography: elasticity imaging using ultrasound with application to muscle and breast in vivo. Ultrasonic Imaging, 1993quem mais cita →
- 9CIRS Tissue Simulation & Phantom Technology. CIRS elasticity QA phantom datasheet: model 049 & 049A. 2013quem mais cita →
- 10MO Culjat, D Goldenberg, P Tewari e mais 1. A review of tissue substitutes for ultrasound imaging. Ultrasound in Medicine & Biology, 2010quem mais cita →
- 11MM Doyley. Model-based elastography: a survey of approaches to the inverse elasticity problem. Physics in Medicine and Biology, 2012quem mais cita →
- 12Q Fang e DA Boas. Tetrahedral mesh generation from volumetric binary and grayscale images. 2009quem mais cita →
- 13PR Hoskins. Simulation and validation of arterial ultrasound imaging and blood flow. Ultrasound in Medicine & Biology, 2008quem mais cita →
- 14JA Jensen e SI Nikolov. Fast simulation of ultrasound images. 2000quem mais cita →
- 15JA Jensen e NB Svendsen. Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992quem mais cita →
- 16F Kallel e J Ophir. A least-squares strain estimator for elastography. Ultrasonic Imaging, 1997quem mais cita →
- 17PI Kattan. MATLAB guide to finite elements: an interactive approach. 2008quem mais cita →
- 18DM King, CM Moran, JD McNamara e mais 2. Development of a vessel-mimicking material for use in anatomically realistic Doppler flow phantoms. Ultrasound in Medicine & Biology, 2011quem mais cita →
- 19CL Korte, EI Céspedes e AFW van der Steen. Influence of catheter position on estimated strain in intravascular elastography. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999quem mais cita →
- 20MN Kurnaz, Z Dokur e T Ölmez. An incremental neural network for tissue segmentation in ultrasound images. Computer Methods and Programs in Biomedicine, 2007quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda