Research on Biomedical Engineering2016
A robust fully automatic lumen segmentation method for in vivo intracoronary optical coherence tomography
Maysa Malfiza Garcia de Macedo, Celso Kiyoshi Takimura, Pedro Alves Lemos e Marco Antonio Gutierrez
em inglês
resumo
Abstract Introduction: Intravascular optical coherence tomography (IVOCT) is an in-vivo imaging modality based on the introduction of a catheter in a blood vessel for viewing its inner wall using electromagnetic radiation. One of the most developed automatic applications for this modality is the lumen area segmentation, however on the evaluation of these methods, the slices inside bifurcation regions, or with the presence of complex atherosclerotic plaques and dissections are usually discarded. This paper describes a fully-automatic method for computing the lumen area in IVOCT images where the set of slices includes complex atherosclerotic plaques and dissections. Methods The proposed lumen segmentation method is divided into two steps: preprocessing, including the removal of artifacts and the second step comprises a lumen detection using morphological operations. In addition, it is proposed an approach to delimit the lumen area for slices inside bifurcation region, considering only the main branch. Results Evaluation of the automatic lumen segmentation used manual segmentations as a reference, it was performed on 1328 human IVOCT images, presenting a mean difference in lumen area and Dice metrics of 0.19 mm2 and 97% for slices outside the bifurcation, 1.2 mm2 and 88% in the regions with bifurcation without automatic contour correction and 0.52 mm2 and 90% inside bifurcation region with automatic contour correction. Conclusion This present study shows a robust lumen segmentation method for vessel cross-sections with dissections and complex plaque and bifurcation avoiding the exclusion of such regions from the dataset analysis.
como citar · ABNT NBR 6023
MACEDO, Maysa Malfiza Garcia de et al. A robust fully automatic lumen segmentation method for in vivo intracoronary optical coherence tomography. Research on Biomedical Engineering, 2016. DOI: 10.1590/2446-4740.0759.
Referências
32 obras citadas
- 1G Borgefors. Distance transformations in digital images. Computer Vision Graphics and Image Processing, 1986quem mais cita →
- 2R Diletti, HM Garcia-Garcia, J Gomez-Lara e mais 7. Assessment of coronary atherosclerosis progression and regression at bifurcations using combined IVUS and OCT. JACC: Cardiovascular Imaging, 2011quem mais cita →
- 3AV Finn, Y Chandrashekhar e J Narula. IVUS and OCT: either or survivor. JACC: Cardiovascular Imaging., 2011quem mais cita →
- 4N Gonzalo, HM Garcia-Garcia, E Regar e mais 5. In vivo assessment of high-risk coronary plaques at bifurcations with combined intravascular ultrasound and optical coherence tomography. JACC: Cardiovascular Imaging, 2009quem mais cita →
- 5ImageJ. Image processing and analysis in Java. 2015quem mais cita →
- 6T Ingebrigtsen, MK Morgan, K Faulder e mais 3. Bifurcation geometry and the presence of cerebral artery aneurysms. Journal of Neurosurgery, 2004quem mais cita →
- 7I Kronzon e P Tunick. Aortic atherosclerotic disease and stroke. Circulation, 2006quem mais cita →
- 8MMG Macedo, CK Takimura, PA Lemos e mais 1. An automatic labeling bifurcation method for intracoronary optical coherence tomography images. 2015quem mais cita →
- 9MMG Macedo, WVN Guimarães, MZ Galon e mais 3. A bifurcation identifier for IV-OCT using orthogonal least squares and supervised machine learning. Computerized Medical Imaging and Graphics, 2015quem mais cita →
- 10MC Moraes, DAC Cardenas e SS Furuie. Automatic lumen segmentation in IVOCT images using binary morphological reconstruction. Biomedical Engineering Online, 2013quem mais cita →
- 11N Otsu. A threshold selection method from gray-level histograms. IEEE Transactions on Systems, Man, and Cybernetics, 1979quem mais cita →
- 12F Prati, E Regar, GS Mintz e mais 10. Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. European Heart Journal, 2010quem mais cita →
- 13K Sihan, C Botha, F Post e mais 6. Fully automatic three-dimensional quantitative analysis of intracoronary optical coherence tomography: method and validation. Catheterization and Cardiovascular Interventions : Official Journal of the Society for Cardiac Angiography & Interventions, 2009quem mais cita →
- 14K Sihan, C Botha, F Post e mais 4. A novel approach to quantitative analysis of intravascular optical coherence tomography imaging. 2008quem mais cita →
- 15I Sobel. An isotropic 3x3 image gradient operator. Machine Vision for Three-Dimensional Scenes, 1990quem mais cita →
- 16MJ Suter, GJ Tearney e BE Bouma. Progress in intracoronary optical coherence tomography. IEEE Journal of Selected Topics in Quantum Electronics, 2010quem mais cita →
- 17C Tomasi e R Manduchi. Bilateral filtering for gray and color images. 1998quem mais cita →
- 18S Tsantis, GC Kagadis, K Katsanos e mais 3. Automatic vessel lumen segmentation and stent strut detection in intravascular optical coherence tomography. Medical Physics, 2012quem mais cita →
- 19K Tung, W Bei e W Shi. Multi-atlas based neointima segmentation in intravascular coronary OCT. 2013quem mais cita →
- 20K Tung, W Shi, R De Silva e mais 2. Automatic vessel wall detection in intravascular coronary OCT. 2011quem mais cita →
Quem cita esta obra
nenhum artigo do acervo cita esta obra — ainda
É sua obra?
Receba um aviso quando um artigo novo citar este trabalho.
também serve para acompanhar o autor que você estuda