GE-Portuguese Journal of Gastroenterology2018

How SpyGlassTM May Impact Endoscopic Retrograde Cholangiopancreatography Practice and Patient Management

Pedro Pereira, Filipe Vilas-Boas, Armando Peixoto, Patrícia Andrade, Joanne Lopes e Guilherme Macedo

em inglês

citado por 1 artigocita 19 obras

resumo

Introduction: Cholangiopancreatoscopy with SpyGlassTM Direct Visualization System (SGDVS) is being used in specialized centers for improving the sensitivity of endoscopic retrograde cholangiopancreatography (ERCP) in patients with indeterminate pancreatobiliary strictures (PBS). The aims of this study were to report our initial experience with SGDVS in the evaluation of indeterminate PBS, and discuss the improvements of ERCP brought by this technique in our center. Methods: The usefulness of SGDVS in patients with indeterminate PBS (defined after nondiagnostic previous ERCP with brush cytology) was evaluated in a prospective observational cohort study conducted at a single tertiary biliopancreatic unit. The accuracy of diagnosis by the SGDVS visual findings, SGDVS-guided biopsy, technical success, image quality, change in patient management after the procedure, and complication rate were assessed. Results: In our single-center cohort, there were 13 SGDVS procedures for evaluating indeterminate PBS. Technical success, defined by the ability to progress with the SpyScope to the target lesion, was achieved in all the cases. The diagnostic accuracy of visual findings (87.5%) was superior to SGDVS-guided biopsy (55%). In 11 (85%) procedures, the image quality was considered good. The procedure permitted exclusion of malignancy and avoiding surgery in 9 patients (69%). There were no complications during the procedures. However, in the post-procedure monitoring, 3 patients developed acute pan-creatitis (19%) and 2 patients developed acute cholangitis (13%). Conclusion: The SGDVS can be considered useful in the context of indeterminate PBS. The intervention is associated with high procedural success and alters clinical outcome compared to conventional approaches.

como citar · ABNT NBR 6023

PEREIRA, Pedro et al. How SpyGlassTM May Impact Endoscopic Retrograde Cholangiopancreatography Practice and Patient Management. GE-Portuguese Journal of Gastroenterology, 2018. DOI: 10.1159/000481859.

Referências

19 obras citadas

  1. 1P Tummala, S Munigala, MA Eloubeidi e mais 1. Patients with obstructive jaundice and biliary stricture +/- mass lesion on imaging: prevalence of malignancy and potential role of EUS-FNA. J Clin Gastroenterol, 2013quem mais cita →
  2. 2A Larghi, A Tringali, PG Lecca e mais 2. Management of hilar biliary strictures. Am J Gastroenterol, 2008quem mais cita →
  3. 3AS Burnett, TJ Calvert e RJ Chokshi. Sensitivity of endoscopic retrograde cholangiopancreatography standard cytology: 10-years review of the literature. J Surg Res, 2013quem mais cita →
  4. 4AS Burnett, J Bailey, JB Oliver e mais 2. Sensitivity of alternative testing for pancreaticobiliary cancer: a 10-years review of the literature. J Surg Res, 2014quem mais cita →
  5. 5M Ramchandani, DN Reddy, R Gupta e mais 3. Role of single-operator peroral cholangioscopy in the diagnosis of indeterminate biliary lesions: a single-center, prospective study. Gastrointest Endosc, 2011quem mais cita →
  6. 6E Kalaitzakis, GJ Webster, KW Oppong e mais 3. Diagnostic and therapeutic utility of single-operator peroral cholangioscopy for indeterminate biliary lesions and bile duct stones. Eur J Gastroenterol Hepatol, 2012quem mais cita →
  7. 7R Manta, M Frazzoni, R Conigliaro e mais 3. SpyGlass single-operator peroral cholangioscopy in the evaluation of indeterminate biliary lesions: a single-center, prospective, cohort study. Surg Endosc, 2013quem mais cita →
  8. 8YS Woo, JK Lee, SH Oh e mais 3. Role of SpyGlass peroral cholangioscopy in the evaluation of indeterminate biliary lesions. Dig Dis Sci, 2014quem mais cita →
  9. 9A Siiki. Spyglass single-operator peroral cholangioscopy seems promising in the evaluation of primary sclerosing cholangitis-related biliary strictures. Scand J Gastroenterol, 2014quem mais cita →
  10. 10A Siiki, I Rinta-Kiikka, T Koivisto e mais 3. Diagnostic and therapeutic utility of SpyGlass® peroral cholangioscopy in intraductal biliary disease: single-center, retrospective, cohort study. Dig Endosc, 2015quem mais cita →
  11. 11U Navaneethan, MK Hasan, V Lourdusamy e mais 3. Single-operator cholangioscopy and targeted biopsies in the diagnosis of indeterminate biliary strictures: a systematic review. Gastrointest Endosc, 2015quem mais cita →
  12. 12W Laleman, K Verraes, W Van Steenbergen e mais 3. Usefulness of the single-operator cholangioscopy system SpyGlass in biliary disease: a single-center prospective cohort study and aggregated review. Surg Endosc, 2017quem mais cita →
  13. 13B Njei, TR McCarty, S Varadarajulu e mais 1. Cost utility of ERCP-based modalities for the diagnosis of cholangiocarcinoma in primary sclerosing cholangitis. Gastrointest Endosc, 2017quem mais cita →
  14. 14YK Chen e DK Pleskow. SpyGlass single-operator peroral cholangiopancreatoscopy system for the diagnosis and therapy of bile-duct disorders: a clinical feasibility study (with video). Gastrointest Endosc, 2007quem mais cita →
  15. 15RJ Shah, I Raijman, B Brauer e mais 2. Performance of a fully disposable, digital, single-operator cholangiopancreatoscope. Endoscopy, 2017quem mais cita →
  16. 16YK Chen, MA Parsi, KF Binmoeller e mais 3. Single-operator cholangioscopy in patients requiring evaluation of bile duct disease or therapy of biliary stones (with videos). Gastrointest Endosc, 2011quem mais cita →
  17. 17T Itoi, H Neuhaus e YK Chen. Diagnostic value of image-enhanced video cholangiopancreatoscopy. Gastrointest Endosc Clin N Am, 2009quem mais cita →
  18. 18S Varadarajulu, JY Bang, MK Hasan e mais 3. mproving the diagnostic yield of single-operator cholangioscopy-guided biopsy of indeterminate biliary strictures: ROSE to the rescue. Gastrointest Endosc, 2016quem mais cita →
  19. 19A Sethi, YK Chen, GL Austin e mais 3. ERCP with cholangiopancreatoscopy may be associated with higher rates of complications than ERCP alone: a single-center experience. Gastrointest Endosc, 2011quem mais cita →

Quem cita esta obra

1 artigo do acervo

quem fala desta obra

9 pessoas

É sua obra?

Receba um aviso quando um artigo novo citar este trabalho.

também serve para acompanhar o autor que você estuda
Acompanhar as citações